45
<Sysname>
NOTE:
•
The 12500E routing switches provide a command line interface (CLI). For more information about
the CLI, see
HP FlexFabric 12500 and 12500E Routing Switch Series Fundamentals Configuration
Guide.
•
The output depends on your switch model.
Verification after power-on
HP recommends that you check the following conditions after the switch is powered on:
•
The cooling system is operating. You should be able to hear fan rotation noise and feel air being
blown out.
•
All the system LEDs on the MPUs are functioning correctly.
Table 11
LED status when the 12508E/12518E operates correctly
Module LED
Status
MPU
SFC (red and green)
Flashing green
LC (red and green)
Flashing green
FAN (red and green)
Flashing green
PWR (red and green)
Flashing green
ACT (green)
Steady on
RUN (red and green)
Flashing green
LPU
RUN (red and green)
Flashing green
Switching fabric module RUN (red and green)
Flashing green
Power monitoring
module
RUN (green)
Flashing
ALM (red)
Off
Fan
RUN (green)
Flashing
ALM (red)
Off
Connecting the switch to the network
TIP:
After connecting the switch to the network, you can use the
ping
or
tracert
command to check the
interoperability between the switch and network. For more information, see
HP FlexFabric 12500 and
12500E Routing Switch Series Network Management and Monitoring Configuration Guide.