![HP E4401B Programmer'S Manual Download Page 247](http://html.mh-extra.com/html/hp/e4401b/e4401b_programmers-manual_161548247.webp)
Chapter 5
5-93
Language Reference
SENSe Subsystem
SENSe:OBWidth Subsection
Set OBW Number of Averages
[:SENSe]:OBWidth:AVERage:COUNt <integer>
Set the occupied bandwidth measurement number of averages.
Remarks:
This command is used for measurements in the
MEASURE
menu.
Front Panel
Access:
none
OBW Averaging On/Off
[:SENSe]:OBWidth:AVERage[:STATe] OFF|ON|0|1
Turn on or off occupied bandwidth averaging.
Factory Preset
and *RST:
Off
Remarks:
This command is used for measurements in the
MEASURE
menu.
Front Panel
Access:
Meas Setup, Avg Number On Off
Set OBW Span
[:SENSe]:OBWidth:FREQuency:SPAN <freq>
Set the occupied bandwidth span. The analyzer span will retain this
value throughout the measurement.
Remarks:
This command is used for measurements in the
MEASURE
menu.
Front Panel
Access:
Meas Setup, OBW Span
Set OBW % Power
[:SENSe]:OBWidth:FREQuency:SPAN <freq>
Set the occupied bandwidth power in percent.
Remarks:
This command is used for measurements in the
MEASURE
menu.
Front Panel
Access:
Meas Setup, Occ BW % Pwr
Summary of Contents for E4401B
Page 6: ...vi ...
Page 14: ...xiv Contents ...
Page 64: ...2 34 Chapter2 HP ESA Status Registers Using the Analyzer Status Registers ...
Page 65: ...3 1 3 Programming Examples ...
Page 151: ...4 1 4 Programming Command Cross References ...
Page 286: ...5 132 Chapter5 Language Reference UNIT Subsystem ...
Page 287: ...6 1 6 HP 8590 HP ESA Spectrum Analyzers Programming Conversion Guide ...
Page 292: ...1 HP 8590 HP ESA Spectrum Analyzers Conversion Guide ...
Page 368: ...7 1 7 Error Messages ...
Page 393: ...7 26 Chapter7 Error Messages 201 to 799 Device Specific Errors ...