background image

 

Front View:

Rear View:

1.

CD-ROM Drive

1.

PSU fan

2.

Power LED

2.

PS/2 mouse port

3.

Drive Activity LED

3.

PS/2 keyboard port

4.

Well ventilated chassis design

4.

VGA port

5.

Full Length Card Retainer

5.

Serial port A

6.

HDD controller card (Optional)

6.

Rear USB 2.0 ports

7.

HP LO 100c Management Card (Optional)

7.

LAN port (RJ-45)

8.

Main System Board

8.

HP LO100c Remote Management Card port (Optional)

9.

Rear System Fan

9.

PCI slot covers

10.

370W Power Supply

10. Power supply outlet

 

11. Rear system fan
12. PCI slot cover lock

At A Glance

Processor:

Dual-Core AMD Opteron 1000 Series processors
Single-Core Athlon 64 3500+ processors

Memory:

512 MB Standard / 8 GB Maximum of PC2-5300 DDR2 667 MHz ECC unbuffered Memory

Storage Controller:

4 Port SATA controller with Embedded RAID on Motherboard (RAID 0,1,5)

Internal Drive Support:

4 HDD Support:

2TB SATA max storage (utilizing 500GB CTO HDD)
1.2TB SAS max storage (4 x 300GB)

Network Controller:

Embedded NC320i PCI Express Gigabit Server Adapter

Expansion Slots:

Two 32-bit/33MHz PCI at 3.3V slot
Two PCI-Express slots (x8 and x16).

USB Ports:

Eight total USB ports (2 internal, 2 front, 4 rear)

Form Factor:

Micro ATX tower

Management:

Standard IPMI reporting
Lights Out 100c Remote Management Card (Optional)

Warranty:

Protected by HP Services and a worldwide network of HP Authorized Channel Partners, including a one-year,
limited warranty, Next Business Day 1, year on-site limited Global warranty. Certain restrictions and exclusions
apply. SATA hard drives have a one year warranty. (3-1-1 warranty offered in AP only).

Summary of Contents for Computer Parts

Page 1: ...R2 667 MHz ECC unbuffered Memory Storage Controller 4 Port SATA controller with Embedded RAID on Motherboard RAID 0 1 5 Internal Drive Support 4 HDD Support 2TB SATA max storage utilizing 500GB CTO HDD 1 2TB SAS max storage 4 x 300GB Network Controller Embedded NC320i PCI Express Gigabit Server Adapter Expansion Slots Two 32 bit 33MHz PCI at 3 3V slot Two PCI Express slots x8 and x16 USB Ports Eig...

Page 2: ...Ie Gigabit Server Adapter Expansion Slots Slot Number Bus Speed Hot Plug Y N PCI Voltage Notes 4 X16 PCI Express No n a Full Height 3 X8 PCI Express No n a In a x8 slot Full Height 1 2 32bit 33MHz PCI No 3 3V Full Height NOTE Only one brace for full length cards provided NOTE Slot 2 only supports standard PCI 32 bit add on card due to proximity of the Heat Sink Storage Controller One of the follow...

Page 3: ...building across town or around the globe NOTE Flexible and volume quantity license kits are available for ProLiant Essentials Value Packs Refer to http www hp com servers proliantessentials or the various ProLiant Essentials Value Pack product QuickSpecs for more information Core Infrastructure Management Subscriber s Choice Subscriber s Choice Driver and Support Alerts Notifications is a web base...

Page 4: ...ore Linux OS support certification information please visit our the ProLiant Bladesystem Server Linux matrix http h18004 www1 hp com products servers linux hpLinuxcert html Factory Express Portfolio for Servers and Storage HP Factory Express offers configuration customization integration and deployment services for HP servers and or storage products Customers can choose how their factory solutions...

Page 5: ...r the same coverage period as the server Coverage of UPS Battery is not included and standard warranty terms conditions apply For servers or storage systems installed within a rack service also covers all HP qualified rack options installed within the same rack To fully capitalize on your HP ProLiant servers capabilities requires a service partner who thoroughly understands your server technology ...

Page 6: ...4 Port SATA Controller with embedded RAID 0 1 5 Hard Drive 160GB SATA HDD Internal Storage Maximum 2TB 4 x 500GB SATA Optical Drive 48x CD ROM Form Factor Micro ATX Tower SAS Models ML115 Opteron 1214 NHP SAS 1P 437290 xx1 Processor s 1 Dual Core AMD Opteron 1214 2 2GHz 2MB Cache Cache Memory 2MB 2x1MB Level 2 cache Opteron Memory 512 MB PC2 5300 ECC DDR2 667Mhz 1 x 512 MB Storage Controller HP 8 ...

Page 7: ...t unless otherwise noted Processors AMD Athlon Processor Model 3500 2 2 GHz Option Kit FIO 440962 L21 AMD Opteron Processor Model 1220SE 2 8 GHz Option Kit FIO 437376 L21 AMD Opteron Processor Model 1216 2 4 GHz Option Kit FIO 437375 L21 AMD Opteron Processor Model 1214 2 2 GHz Option Kit FIO 437374 L21 AMD Opteron Processor Model 1210 1 8 GHz Option Kit FIO 437373 L21 Memory 2 GB Unbuffered PC2 5...

Page 8: ...r additional information Operating Systems Pre install Microsoft Windows 2003 SBS Standard Edition MS W2003 SBS R2 Std 1XX FIO Eng SW 432564 xx1 MS W2003 SBS R2 Prm 1XX FIO Eng SW 432566 xx1 Country Code Key xx 00 NA xx 01 Australia xx 03 UK xx 04 Germany xx 05 France xx 06 Italy xx 07 Spanish xx 20 Brazil xx 21 Hungarian xx 22 Czech xx 24 Polish xx 33 Dutch xx 37 AP xx 42 Euro xx AA PRC xx 29 Jap...

Page 9: ...s requires the purchase of part number 430479 B21 the HP Internal SAS SATA 4 Port Cable This cable is standard in the SAS BTO model Storage Controllers HP SC44Ge Host Bus Adapter 416096 B21 HP SC11Xe Host Bus Adapter 412911 B21 HP 8 Internal Port SAS HBA with RAID NOTE PCI X Interface PCI 32bit 33MHz compatible NOTE Slot 2 only supports standard PCI 32 bit add on card due to proximity to Heat Synk...

Page 10: ...p System NOTE 1TB of Disk Storage EH880A HP StorageWorks D2D110 Backup System with Data Protector Express Software Kit NOTE 1TB of Disk Storage EH923A HP StorageWorks D2D120 Backup System NOTE 2TB of Disk Storage EH884A HP StorageWorks D2D120 Backup System with Data Protector Express Software Kit NOTE 2TB of Disk Storage EH924A HP StorageWorks D2D130 Backup System NOTE 3TB of Disk Storage EH950A H...

Page 11: ...SB 2 0 4 port HUB DG954A HP KVM Switch Options HP 1x4 Console Switch AF611A HP PS2 Server Console Cable 6 foot 2 Pack AF612A HP USB Server Console Cable 6 foot 2 Pack NOTE Required for supporting USB peripherals AF613A NOTE For additional information regarding KVM Switches Serial Console servers rack mount monitors keyboards and all related options please see the following URL http www hp com go k...

Page 12: ...rs U4435E Hardware Services Next Business Day On Site Service 9 Hour x 5 Day Coverage 3 Years U4433E Hardware Services 6 Hour Call to Repair 24 Hour x 7 Day Coverage 3 Years 6 Hour Call to Repair U4436E Hardware Installation Service HP Install ProLiant ML115 Service U4444E NOTE For more information customer resellers can contact http www hp com services carepack ...

Page 13: ... buffered ECC DDR2 SDRAM DIMM Memory kits NOTE The below chart does not represent all possible memory configurations NOTE In memory configurations requiring 2 DIMM and 4 DIMM configurations the memory must be paired for optimal performance This means that DIMMs in slot 1 and 3 have to be identical in slot 2 and 4 have to be identical For example the Optional memory configuration shown below Memory...

Page 14: ... Supported Controller 3 5 inch 500GB 7 2K SATA 250GB 7 2K SATA 160GB 7 2K SATA 80GB 7 2K SATA Up to 4 3 4 5 6 4 Port SATA controller with Embedded RAID on Motherboard 0 1 5 Hard Drives SAS Models only SAS Non Hot Plug Quantity Supported Position Supported Controller 3 5 inch 300GB 15K SAS 145GB 15K SAS 72GB 15K SAS Up to 4 3 4 5 6 HP 8 Internal Port SAS HBA with RAID 0 1 Maximum Storage Capacity S...

Page 15: ...umber Internal USB Tape Drives DAT 40 USB DAT 72 USB DAT 160 USB 2 USB 2 0 port N A External USB Tape Drives DAT 40 USB DAT 72 USB DAT 160 USB External USB 2 0 port N A Internal SAS Tape Drives DAT 160 SAS 2 HP SC44Ge Host Bus Adapter 416096 B21 External SAS Tape Drives DAT 160 SAS External HP SC44Ge Host Bus Adapter 416096 B21 Internal SCSI Tape Drives DAT 40 DAT 72 DAT 160 2 HP SC11Xe Host Bus A...

Page 16: ...t Current A rms N A 8 N A N A 4 N A Max Rated Input Wattage Rating Watts N A N A N A N A N A N A Max Rated VA Volt Amp N A N A N A N A N A N A Efficiency N A 65 N A N A 65 N A Power Factor N A N A N A N A N A N A Leakage Current mA 0 25mA at 60HZ N A N A N A N A N A Maximum Inrush Current A peak N A No component was damaged and input fuse shall not blow N A N A No component was damaged and input f...

Page 17: ...th all power supplies loaded A 80A Power cord requirements Nema 5 15P to IEC320 C13 IEC320 C13 to IEC320 C14 Power shown is for a fully configured system consisting of 1 CPU 4 double sided DIMMs 4 HDDs 1 CD ROM 1 DVD ROM 4 PCI cards and 1 power supply Power Cords 13 Cord Sets Power Cord Part Number Country APD 100614 009 100613 008 139867 004 187487 004 India Brazil 285052 001 Australia 100661 001...

Page 18: ...aximum Peak Power 370W Temperature Range Operating 50 to 95 F 10 to 35 C Shipping 31 to 140 F 35 to 60 C Relative Humidity non condensing Operating 10 to 90 Non operating 10 to 95 Acoustic Noise Idle Fixed Disk Drives Spinning L WAd BELS 5 4 L pAm dBA 36 Operating Random Seeks to Fixed Disks L WAd BELS 5 9 L pAm dBA 38 HP 160GB 1 5G SATA 7 2K NHP 3 5 HDD 411275 B21 160GB 7 200 rpm Capacity 160 041...

Page 19: ...to CD Single and Multi session Mixed Mode Audio and Data combined CD R Capacity 540MB Mode 1 12 cm 650MB Mode 2 12 cm Block Size Mode 1 2 048 bytes 1024 bytes Mode 2 2 340 bytes 2 336 bytes 1024 bytes CD DA 2 352 bytes CD XA 2 328 bytes Interface IDE ATAPI Access Times typical Random 100 ms Full Stroke 150 ms Data Transfer Rate Sustained 3000 to 7200 KB s 20X to 48X Burst 150 KBps to 7 200 KBps Bu...

Page 20: ...Gbps SATA Serial Advanced Technology Attachment Architecture 64 bit SAS Connectors 2 internal SFF8484 x4 Wide SAS Connectors 12 Gbps per x4 Wide SAS Port 4 x 3 Gbps Data Transfer Method 64 bit wide PCI X 133 MHz 1 GB s maximum bandwidth PCI Bus Speed PCI X 133 and 3 3 volt PCI compatibility only PCI PCI X and 3 3 volt PCI compatibility only Simultaneous Drive Transfer Ports 2 x4 Wide SAS Connector...

Page 21: ...P will be recycled recovered or disposed of in a responsible manner The EU WEEE directive 2002 95 EC requires manufacturers to provide treatment information for each product type for use by treatment facilities This information product disassembly instructions is posted on the Hewlett Packard web site at http www hp com go green These instructions may be used by recyclers and other WEEE treatment ...

Reviews: