a.
Position the heatsink on the processor backplate.
b.
Tighten one pair of diagonally opposite screws halfway, and then tighten the other pair of screws.
c.
Finish the installation by completely tightening the screws in the same sequence.
.
16. Install any removed PCI riser cage assemblies
17. Install the node into the chassis
.
18.
Connect all peripheral cables to the node.
Installing the dedicated iLO management port module option
Prerequisites
Observe the following rules and limitations when installing an dedicated iLO management port module:
• If a dedicated iLO management port module is installed in a node, the node can only connect to a network
through the dedicated iLO management port module.
• If a dedicated iLO management port module is installed in a node, the node cannot be accessed through
the RCM module.
• If using the RCM module iLO ports or the dedicated iLO management port module to connect to a
network, the network must operate at a speed of 1 Gb/s. The server cannot connect to the network if the
network is operating at a speed of 10/100 Mb/s or 10 Gb/s.
About this task
For more information about product features, specifications, options, configurations, and compatibility, see the
product QuickSpecs on the
Hewlett Packard Enterprise website
Procedure
1.
2.
Disconnect all peripheral cables from the node.
3.
Remove the node from the chassis
4.
Place the node on a flat, level surface.
5.
Remove any installed PCI riser cage assemblies
.
6.
.
7.
Remove the knockout.
156
Installing the dedicated iLO management port module option