TIP:
When you receive an Integrity rx6600 server from Hewlett Packard Enterprise, if you ever
plan to add other SAS devices into the system, you should consider moving the SAS devices so
they start in bay 1 going upwards instead of Bay 8 going downwards.
Installing a Hot-Pluggable Disk Drive
NOTE:
The replacement disk drive must have the same product number as the disk drive that
you replace.
To install a hot-pluggable disk drive, follow these steps:
1.
Use
to determine the next available disk drive installation slot.
2.
Remove the disk drive filler if required. See
“Removing a Hot-Swappable Disk Drive Filler”
NOTE:
Save the disk drive filler for future use. For cooling purposes, always place disk
drive fillers in slots that do not contain a disk drive.
3.
Insert the hot-pluggable disk drive into the slot guides, and slide the drive into the slot until
it seats into the socket on the disk backplane.
4.
Close the drive ejector handle by pushing it inward until it clicks into place.
Figure 21 Removing and Replacing a Hot-Pluggable Disk Drive
Installing Additional Components
51