Installing and Configuring the Core Switch 2/64
42
Core Switch 2/64 V4.1 Installation Guide
Table 5: Core Switch 2/64 Carton Contents Checklist
Item
Summary
1
Core Switch 2/64 populated with two 16-port cards, two CP cards, four power
supplies and three blower assemblies.
2
StorageWorks Fibre Channel Core Switch 2/64 Installation Guide,
Release Notes
,
software CD, and license
3
One Accessory Kit containing one ESD grounding strap, sixteen cable guides, and two
power cord retainers, with Phillips screws (#4-40), and #1 Phillips screwdriver as a
required tool
4
RS-232 serial cable with an RJ-45 adapter
5
AC power cords (2) Currently two set of power cords that are shipped with the Core
Switch 2/64 switch. One set is for pmHP & the other set is for pmCPQ.
For the pmHP Core Switch, two jumper cables (C19 – C20) are provided to connect
from the switch to the PDU. The PDU that we recommend is E7671A. Two E7671A are
recommended for power redundancy. The recommended power cords to connect from
the PDU to the wall are E7803A, E7805A, E7806A, E7808A, E7809A. Both are
standard US receptacles. These cables are then plugged into a PDU (Power Distribution
Unit) in the rack, which is customized by country.
6
14U Rack Mount Kit containing: Left rack mount shelf bracket, (1); Right rack mount
shelf bracket, (1)
• Left upper rack mount bracket assembly, includes: Left upper rack mount bracket
(flat); Left upper rack mount bracket (L-shaped); Screw (torque to 32 inch-pounds)
• Right upper rack mount bracket assembly, includes: Right upper rack mount bracket
(flat); Right upper rack mount bracket (L-shaped); Screw (torque to 32 inch-pounds)
• M5 Tinnermans (0590-2318) and M5 Torx screws (0515-0671) are required
pieces of rack mount kit hardware.
7
• Seven pouches containing 14U Rack Mount Kit hardware; #10-32 x 5/16 Phillips
flathead screws (8); #10-32 x 5/16 Phillips panhead screws with washers (4)
• For use with the 9000 Series 42U rack (or racks with square holes): #10-32 x 5/16
retainer nuts; #1/4-20 x 0.500 Phillips panhead screws with glue (16); 0.375-inch
square washers (16)
• For use with rack with round holes: #10-32 clip nut (package of 20, only 4
required); #1/4-20 x 1/2 inch Phillips panhead screws, with lockhead washers (16)
Summary of Contents for AA-RS2WC-TE
Page 12: ...Contents 12 Core Switch 2 64 V4 1 Installation Guide ...
Page 34: ...Overview 34 Core Switch 2 64 V4 1 Installation Guide ...
Page 88: ...Installing and Configuring the Core Switch 2 64 88 Core Switch 2 64 V4 1 Installation Guide ...
Page 168: ...Running Routine Operations 168 Core Switch 2 64 V4 1 Installation Guide ...
Page 198: ...Technical Specifications 198 Core Switch 2 64 V4 1 Installation Guide ...
Page 224: ...Setting Up and Configuring Modems 224 Core Switch 2 64 V4 1 Installation Guide ...