204 

reboot

: Specifies that when a software exception occurs on an MPU, the switch automatically reboots the 

MPU to recover it from the error condition. 

Description 

Use the 

system-failure

 command to configure the software exception handling method for MPUs. 

By default, an MPU reboots to recover from a software exception condition.  
In an IRF fabric, the software exception handling method applies to all member switches.  

 

 

NOTE: 

An LPU always reboots to recover from a software exception condition.  

 

Examples 

# Set the software exception handling method to reboot for MPUs. 

<Sysname> system-view 

[Sysname] system-failure reboot 

temperature-limit 

Syntax 

In standalone mode:

 

temperature-limit

 

slot 

slot-number

 

hotspot 

sensor-number

 

lowerlimit warninglimit 

alarmlimit

 ] 

undo temperature-limit slot 

slot-number

 

hotspot 

sensor-number 

In IRF mode: 

temperature-limit

 

chassis

 

chassis-number

 

slot 

slot-number

   

hotspot 

sensor-number

 

lowerlimit 

warninglimit 

alarmlimit

 ] 

undo temperature-limit chassis

 

chassis-number

 

slot 

slot-number

 

hotspot 

sensor-number 

 

View 

System view 

Default level 

2: System level 

Parameters 

chassis 

chassis-number

: Specifies an IRF member switch. The 

chassis-number

 argument represents the IRF 

member ID of the switch. (In IRF mode)

 

slot 

slot-number

: Specifies a card in the specified switch. The 

slot-number

 argument represents the slot 

number of the card.  

hotspot

: Specifies a hotspot sensor. Hotspot sensors are placed near major heat sources, for example, 

chips, to monitor their temperature.

 

sensor-number

: Specifies a sensor number, an integer that increases from 1.  

lowerlimit

: Low temperature threshold in Celsius degrees. The value ranges from –5°C to +5°C (23°F to 

41°F). 

Summary of Contents for A7500 Series

Page 1: ...HP A7500 Switch Series Fundamentals Command Reference Part number 5998 1877 Software version Release 6626 and later Document version 6W101 20111130 ...

Page 2: ...MATERIAL INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Hewlett Packard shall not be liable for errors contained herein or for incidental or consequential damages in connection with the furnishing performance or use of this material The only warranties for HP products and services are set forth in the express warranty statements accompan...

Page 3: ... 13 activation key 14 auto execute command 15 authentication mode 17 command accounting 18 command authorization 19 databits 19 display telnet client configuration 20 display user interface 21 display users 23 escape key 24 flow control 25 free user interface 26 history command max size 27 idle timeout 27 lock 28 modem 29 modem auto answer 30 modem timer answer 30 parity 31 protocol inbound 32 scr...

Page 4: ...ii 49 binary 49 bye 50 cd 50 cdup 51 close 52 debugging 52 delete 54 dir 54 disconnect 55 display ftp client configuration 56 ftp 57 ftp client source 58 ftp ipv6 58 get 60 lcd 61 ls 61 mkdir 62 open 63 open ipv6 64 passive 64 put 65 pwd 66 quit 66 remotehelp 67 rmdir 69 user 69 verbose 70 TFTP client configuration commands 72 display tftp client configuration 72 tftp server acl 72 tftp 73 tftp cl...

Page 5: ...uration 105 display startup 107 display this 109 reset saved configuration 110 restore startup configuration 111 save 112 slave auto update config 115 startup saved configuration 116 Software upgrade commands 118 boot loader 118 bootrom 120 display boot loader 123 display patch 124 display patch information 125 patch active 127 patch deactive 128 patch delete 129 patch install 130 patch load 131 p...

Page 6: ...switch mode status 176 display system failure 177 display transceiver 178 display transceiver alarm 180 display transceiver diagnosis 182 display transceiver manuinfo 183 display version 184 display version update record 186 header 187 job 188 loadsharing enable 189 monitor handshake timeout disable port 189 mmu monitor enable 190 oem hp 191 reboot 192 reset unused porttag 193 reset version update...

Page 7: ...v Index 210 ...

Page 8: ...e command alias function By default the command alias function is disabled Related commands command alias mapping Examples Enable the command alias function Sysname system view Sysname command alias enable Disable the command alias function Sysname system view Sysname undo command alias enable command alias mapping Syntax command alias mapping cmdkey alias undo command alias mapping cmdkey View Sy...

Page 9: ...celing the replacement of the display keyword Sysname system view Sysname undo command alias mapping display command privilege Syntax command privilege level level view view command undo command privilege view view command View System view Default level 3 Manage level Parameters level level Command level in the range of 0 to 3 view view Specifies a view The value shell represents a user view The v...

Page 10: ...you should use the undo command privilege view system ftp server command If you modify the command level of a command in a specified view from the default command level to a lower level remember to modify the command levels of the quit command and the corresponding command used to enter this view For example the default command level of commands interface and system view is 2 system level If you w...

Page 11: ... include regular expression View Any view Default level 1 Monitor level Parameters Filters command output by specifying a regular expression For more information about regular expressions see Fundamentals Configuration Guide begin Displays the first line that matches the specified regular expression and all lines that follow exclude Displays all lines that do not match the specified regular expres...

Page 12: ...n Use the display history command command to display commands saved in the history command buffer By default the system saves the last 10 executed commands in the history command buffer To set the size of the history command buffer use the history command max size command For more information see the chapter Logging in to the switch commands Examples Display history commands in current user view S...

Page 13: ...or one character left CTRL_C Stop current command function CTRL_D Erase current character CTRL_E Move the cursor to the end of the current line CTRL_F Move the cursor one character right CTRL_H Erase the character left of the cursor CTRL_K Kill outgoing connection CTRL_N Display the next command from the history buffer CTRL_P Display the previous command from the history buffer CTRL_R Redisplay th...

Page 14: ...Ctrl U to the specified command command The command line associated with the hot key Description Use the hotkey command to associate a hot key to a command Use the undo hotkey command to restore the default By default Ctrl G Ctrl L and Ctrl O have these corresponding commands Ctrl G corresponds to display current configuration Ctrl L corresponds to display ip routing table Ctrl O corresponds to un...

Page 15: ...hernet2 0 1 quit Sysname quit Sysname return Syntax return View Any view except user view Default level 2 System level Parameters None Description Use the return command to return to user view from the current view which can also be done with the hot key Ctrl Z Related commands quit Examples Return to user view from GigabitEthernet 2 0 1 view Sysname GigabitEthernet2 0 1 return Sysname screen leng...

Page 16: ... level 0 Visit level Parameters level User level in the range of 0 to 3 The default value is 3 Description Use the super command to switch from the current user privilege level to a specified user privilege level If a level is not specified the command switches the user privilege level to 3 Command levels include four privileges visit 0 monitor 1 system 2 and manage 3 You can assign a privilege le...

Page 17: ...ord scheme AAA authentication For more information about AAA see Security Configuration Guide local scheme First local and then scheme which means to authenticate a user by using the local password first If no password is set for the user logged in through the console port the privilege level switch succeeds If no password is set for the user logged in through a VTY user interface the AAA authenti...

Page 18: ...acters in cipher text For example the simple text 1234567 corresponds to the cipher text TT8F Y 5SQ Q MAF4 1 Description Use the super password command to set the password used to switch from the current user privilege level to a higher one Use the undo super password command to restore the default By default no password is set for switching to a higher privilege level A cipher text password is re...

Page 19: ...Q Q MAF4 1 system view Syntax system view View User view Default level 2 System level Parameters None Description Use the system view command to enter system view from the current user view Related commands quit return Examples Enter system view from the current user view Sysname system view System View return to User View with Ctrl Z Sysname ...

Page 20: ...er or SSH server this keyword is used to control access of Telnet clients or SSH clients outbound Restricts Telnet connections established in the outbound direction through the VTY user interface If the packets sent for establishing a Telnet connection are permitted by an ACL rule the connection is allowed to be established When the device functions as a Telnet client this keyword is used to defin...

Page 21: ...ser A with IP address 192 168 1 26 can Telnet to the device while user B with IP address 192 168 1 60 cannot Telnet to the device Upon a connection failure a message appears saying connection closed by remote host Allow the device to only Telnet to the Telnet server with IP address 192 168 1 41 Sysname system view Sysname acl number 3001 Sysname acl adv 3001 rule permit tcp destination 192 168 1 4...

Page 22: ...splay the shortcut key you have defined use the display current configuration include activation key command NOTE The activation key command is not supported by the VTY user interface Examples Configure character s as the shortcut key for starting a terminal session on the console port Sysname system view Sysname user interface aux 0 Sysname ui aux0 activation key s To verify the configuration Exi...

Page 23: ... to the device After the user terminates the connection with the host the user s connection with the device is automatically terminated CAUTION The auto execute command command may disable you from configuring the system through the user interface to which the command is applied Before configuring the command and saving the configuration by using the save command make sure that you can access the ...

Page 24: ...n mode View User interface view Default level 3 Manage level Parameters none Performs no authentication password Performs local password authentication scheme Performs AAA authentication For more information about AAA see Security Configuration Guide Description Use the authentication mode command to set the authentication mode for the user interface Use the undo authentication mode command to res...

Page 25: ...mand accounting undo command accounting View User interface view Default level 3 Manage level Parameters None Description Use the command accounting command to enable command accounting Use the undo command accounting command to restore the default By default command accounting is disabled The accounting server does not record the commands that users have executed When command accounting is enable...

Page 26: ...rization With command authorization enabled users can perform only commands authorized by the server Examples Enable command accounting for VTY 0 so that users logging in from VTY 0 can perform only the commands authorized by the HWTACACS server Sysname system view Sysname user interface vty 0 Sysname ui vty0 command authorization databits Syntax databits 5 6 7 8 undo databits View User interface ...

Page 27: ...ters command output by specifying a regular expression For more information about regular expressions see Fundamentals Configuration Guide begin Displays the first line that matches the specified regular expression and all lines that follow exclude Displays all lines that do not match the specified regular expression include Displays all lines that match the specified regular expression regular ex...

Page 28: ... match the specified regular expression include Displays all lines that match the specified regular expression regular expression Specifies a regular expression a case sensitive string of 1 to 256 characters Description Use the display user interface command to display information about the specified or all user interfaces If the summary keyword is not included the command displays the type of the...

Page 29: ...uthentication mode for the users which can be A P L and N Int The physical port that corresponds to the user interface For AUX and VTY user interfaces is displayed A AAA authentication L Local authentication not supported N No authentication P Password authentication Display summary about all user interfaces Sysname display user interface summary User interface type AUX 0 UX User interface type VT...

Page 30: ... expression regular expression Specifies a regular expression a case sensitive string of 1 to 256 characters Description Use the display users command to display information about the user interfaces that are being used Use the display users all command to display information about all user interfaces supported by the device Examples Display information about the user interfaces that are being use...

Page 31: ... shortcut key For example if you enter an ASCII code value of 1 13 the system uses its corresponding character q as the shortcut key If you enter the string q c the system uses the first character q as the shortcut key default Restores the default escape key combination of Ctrl C Description Use the escape key command to define a shortcut key for terminating a task Use the undo escape key command ...

Page 32: ...a bytes press a to break Reply from 192 168 1 49 bytes 56 Sequence 1 ttl 255 time 3 ms Reply from 192 168 1 49 bytes 56 Sequence 2 ttl 255 time 3 ms Enter a The task terminates immediately and the system returns to system view 192 168 1 49 ping statistics 2 packet s transmitted 2 packet s received 0 00 packet loss round trip min avg max 3 3 3 ms Sysname flow control Syntax flow control hardware no...

Page 33: ...ux vty num2 View User view Default level 3 Manage level Parameters num1 Absolute number of a user interface The value range varies with devices and typically starts from 0 aux Specifies the AUX user interface vty Specifies the VTY user interface num2 Relative number of a user interface The value range varies with devices for an AUX user interface and the value is in the range of 0 to 15 for a VTY ...

Page 34: ...and buffer of the current user interface Use the undo history command max size command to restore the default By default the buffer saves 10 history commands The history command buffer saves executed history commands per user interface and buffers for different user interfaces do not affect each other To display the commands that are stored in the history buffer use the display history command com...

Page 35: ...idle timeout is 10 minutes NOTE The system automatically terminates the user s connection s if there is no information interaction between the device and the users within the idle timeout time Setting idle timeout to zero disables the timer In this case connections are maintained unless you terminate them Examples Set the idle timeout timer to 1 minute and 30 seconds Sysname system view Sysname us...

Page 36: ...ord 1 to 16 to lock current user terminal interface Password Again locked Password Sysname modem Syntax modem both call in call out undo modem both call in call out View AUX interface view Default level 2 System level Parameters both Allows both incoming and outgoing calls call in Allows incoming calls only call out Allows outgoing calls only Description Use the modem command to enable the switch ...

Page 37: ... modem to operate in the auto answer mode Use the undo modem auto answer command to restore the default By default the switch side modem operates in the manual answer mode Examples Configure the switch side modem to operate in the auto answer mode Sysname system view System View return to User View with Ctrl Z Sysname user interface aux 0 Sysname ui aux0 modem auto answer modem timer answer Syntax...

Page 38: ...e odd space undo parity View User interface view Default level 2 System level Parameters even Performs an even parity check mark Performs a mark parity check none Performs no parity check odd Performs an odd parity check space Performs a space parity check Description Use the parity command to set a parity check method Use the undo parity command to restore the default By default no parity check i...

Page 39: ...col inbound command to restore the default By default both protocols are supported NOTE Before configuring a user interface to support SSH set the authentication mode to scheme for the user interface otherwise the protocol inbound ssh command fails For more information see authentication mode By default the authentication mode of the Telnet protocol is password Examples Enable the VTYs 0 through 4...

Page 40: ...multiple screen output of the current user interface use the screen length disable command For more information about the screen length disable command see the chapter CLI commands Examples Set the next screen of the AUX user interface 0 to display 30 lines Sysname system view Sysname user interface aux 0 Sysname ui aux0 screen length 30 send Syntax send all num1 aux vty num2 View User view Defaul...

Page 41: ...dx UI Delay Type Userlevel 18 VTY 0 00 00 00 TEL 3 19 VTY 1 00 00 03 TEL 3 Following are more details VTY 0 Location 192 168 1 26 VTY 1 Location 192 168 1 20 Current operation user F Current operation user work in async mode The output shows that a user is using VTY 0 Sysname send vty 1 Enter message end with CTRL Z or Enter abort with CTRL C Note please I will reboot the system in 3 minutes Z Sen...

Page 42: ...d or the encrypted version of the plain text password comprises 24 characters such as _ TT8F Y 5SQ Q MAF4 1 Description Use the set authentication password command to set an authentication password Use the undo set authentication password command to remove the local authentication password By default no local authentication password is set No matter whether the password format is plain text or cip...

Page 43: ...Examples Disable terminal services on VTYs 0 through 15 which means you cannot log in to the device through VTYs 0 through 15 Sysname system view Sysname user interface vty 0 15 Sysname ui vty0 15 undo shell Disable ui vty0 15 are you sure Y N y Sysname ui vty0 15 The following message appears when a terminal tries to Telnet to the device The connection was closed by the remote host speed user int...

Page 44: ...ting must be identical for the user interfaces of the connecting ports on the device and the target terminal device for communication Examples Set the transmission rate on the AUX 0 user interface to 19200 bps Sysname system view Sysname user interface aux 0 Sysname ui aux0 speed 19200 stopbits Syntax stopbits 1 1 5 2 undo stopbits View User interface view Default level 2 System level Parameters 1...

Page 45: ...defaults to 23 vpn instance vpn instance name Specifies the MPLS L3VPN that the remote system belongs to where vpn instance name is a case sensitive string of 1 to 31 characters source Specifies the source interface or source IPv4 address of Telnet packets interface interface type interface number Specifies the source interface The source IPv4 address of the Telnet packets sent is the IPv4 address...

Page 46: ...d to remove the source IPv4 address or source interface for sending Telnet packets By default no source IPv4 address or source interface for sending Telnet packets is specified The source IPv4 address is selected by routing The source IPv4 address or source interface specified by this command is applicable all Telnet connections If you use both this command and the telnet command to specify the so...

Page 47: ...gs to where vpn instance name is a case sensitive string of 1 to 31 characters Description Use the telnet ipv6 command to Telnet to a remote host in an IPv6 network To terminate the current Telnet connection press Ctrl K or use the quit command Examples Telnet to the remote host with the IPv6 address 5000 1 Sysname telnet ipv6 5000 1 telnet server enable Syntax telnet server enable undo telnet ser...

Page 48: ...e total number of characters of the currently edited command line exceeds 80 an anomaly such as cursor corruption or abnormal display of the terminal display may occur on the client Examples Set the terminal display type to VT100 Sysname system view Sysname user interface vty 0 Sysname ui vty0 terminal type vt100 user privilege level Syntax user privilege level level undo user privilege level View...

Page 49: ...ux vty first num2 last num2 View System view Default level 2 System level Parameters first num1 Absolute number of the first user interface The value range varies with devices and typically starts from 0 last num1 Absolute number of the last user interface The value range varies with devices and typically starts from 0 but cannot be smaller than the first num1 aux Specifies the AUX user interface ...

Page 50: ...kes effect in these user views Examples Enter the user interface view of AUX 0 Sysname system view Sysname user interface aux 0 Sysname ui aux0 Enter the user interface views of VTYs 0 to 4 Sysname system view Sysname user interface vty 0 4 Sysname ui vty0 4 ...

Page 51: ...pression include Displays all lines that match the specified regular expression regular expression Specifies a regular expression a case sensitive string of 1 to 256 characters Description Use the display ftp server command to display the FTP server configuration After configuring FTP server parameters you may verify them with this command Related commands ftp server enable ftp timeout and ftp upd...

Page 52: ...t do not match the specified regular expression include Displays all lines that match the specified regular expression regular expression Specifies a regular expression a case sensitive string of 1 to 256 characters Description Use the display ftp user command to display the detailed information of current FTP users Examples Display the detailed information of FTP users Sysname display ftp user Us...

Page 53: ...manually release the FTP connection established by the specified user This command releases the FTP connection established by the specified user no matter whether the user is transmitting a file Examples Manually release the FTP connection established with username ftpuser Sysname free ftp user ftpuser Are you sure to free FTP user ftpuser Y N y Sysname ftp server acl Syntax ftp server acl acl num...

Page 54: ...nt 1 1 1 1 to access the FTP server through FTP Sysname system view Sysname acl number 2001 Sysname acl basic 2001 rule 0 permit source 1 1 1 1 0 Sysname acl basic 2001 rule 1 deny source any Sysname acl basic 2001 quit Sysname ftp server acl 2001 ftp server enable Syntax ftp server enable undo ftp server View System view Default level 3 Manage level Parameters None Description Use the ftp server ...

Page 55: ...eout 36 ftp update Syntax ftp update fast normal undo ftp update View System view Default level 3 Manage level Parameters fast Fast update In this mode the FTP server writes the complete file to the memory before writing it to the storage medium normal Normal update In this mode the FTP server writes the data of a file from the memory to the storage medium multiple times with up to 4096 bytes per ...

Page 56: ...scii Syntax ascii View FTP client view Default level 3 Manage level Parameters None Description Use the ascii command to set the file transfer mode to ASCII By default the file transfer mode is ASCII The carriage return characters vary with operating systems For example HP and Windows use characters r n and Linux uses characters n To transfer files between two systems that use different carriage r...

Page 57: ...et to I bye Syntax bye View FTP client view Default level 3 Manage level Parameters None Description Use the bye command to disconnect from the remote FTP server and return to user view If no connection is established between the device and the remote FTP server use this command to return to user view directly Related commands close disconnect and quit Examples Terminate the connection with the re...

Page 58: ...argument does not support command line online help Returns to the root directory of the storage medium The keyword does not support command line online help Description Use the cd command to change the current working directory on the remote FTP server to access another authorized directory Related commands pwd Examples Change the working directory to the sub directory logfile of the current direc...

Page 59: ...meters None Description Use the close command to terminate the connection to the FTP server but remain in FTP client view This command is equal to the disconnect command Examples Terminate the connection to the FTP server and remain in FTP client view ftp close 221 Server closing ftp debugging Syntax debugging undo debugging View FTP client view Default level 1 Monitor level Parameters None Descri...

Page 60: ... FTP passive is off ftp debugging FTP debugging switch is on ftp get sample file PORT 192 168 1 44 4 21 200 Port command okay The parsed reply is 200 RETR sample file 150 Opening ASCII mode data connection for sample file The parsed reply is 150 FTPC File transfer started with the signal light turned on FTPC File transfer completed with the signal light turned off 226 Transfer complete FTP 3304 by...

Page 61: ...rmissions on the FTP server Examples Delete file temp c ftp delete temp c 250 DELE command successful dir Syntax dir remotefile localfile View FTP client view Default level 3 Manage level Parameters remotefile Name of the file or directory on the remote FTP server localfile Name of the local file to save the displayed information Description Use the dir command to view the detailed information of ...

Page 62: ...ogroup 0 Aug 08 2006 logfile rwxrwxrwx 1 noone nogroup 20471748 May 11 10 21 test app rwxrwxrwx 1 noone nogroup 4001 Dec 08 2007 config cfg rwxrwxrwx 1 noone nogroup 3608 Jun 13 2007 startup cfg drwxrwxrwx 1 noone nogroup 0 Dec 03 2007 test rwxrwxrwx 1 noone nogroup 299 Oct 15 2007 key pub 226 Transfer complete FTP 394 byte s received in 0 189 second s 2 00K byte s sec ftp View the information of ...

Page 63: ...l lines that follow exclude Displays all lines that do not match the specified regular expression include Displays all lines that match the specified regular expression regular expression Specifies a regular expression a case sensitive string of 1 to 256 characters Description Use the display ftp client configuration command to display the source IP address configuration of the FTP client Related ...

Page 64: ...on this interface is the source address of the transmitted FTP packets If no primary IP address is configured on the source interface the connection fails ip source ip address Specifies the source IP address of the transmitted FTP packets This source address must be the one that has been configured on the device Description Use the ftp command to log in to the remote FTP server and enter FTP clien...

Page 65: ...te to the server is used as the source IP address If you use the ftp client source command to first configure a source interface and then a source IP address the source IP address overwrites the source interface and vice versa If you first use the ftp client source command to specify a source IP address and then use the ftp command to specify another source IP address the latter is used The source...

Page 66: ...P server belongs to The vpn instance name argument is a case sensitive string of 1 to 31 characters Description Use the ftp ipv6 command to log in to the FTP server and enter FTP client view This command applies to IPv6 networks only If you use this command without specifying any parameters you will simply enter the FTP client view without logging in to an FTP server If you specify the parameters ...

Page 67: ...y open transfer starting for testcfg cfg 226 Transfer complete FTP 3608 byte s received in 2 050 second s 1 00K byte s sec Download file testcfg cfg to the root directory of the storage medium of the standby MPU in slot 1 and save it as newest cfg ftp get testcfg cfg slot1 flash newest cfg 227 Entering Passive Mode 192 168 1 46 4 48 125 ASCII mode data connection already open transfer starting for...

Page 68: ...ived in 2 322 second s 1 00K byte s sec lcd Syntax lcd View FTP client view Default level 3 Manage level Parameters None Description Use the lcd command to display the local working directory of the FTP client Examples Display the local working directory ftp lcd FTP Local directory now flash clienttemp The output shows that the working directory of the FTP client before execution of the ftp comman...

Page 69: ...as the size and the date they were created Examples View the information of all files and subdirectories in the current directory of the FTP server ftp ls 227 Entering Passive Mode 192 168 1 50 17 165 125 ASCII mode data connection already open transfer starting for ar router cfg logfile mainar app arbasic app ftp test bb cfg testcfg cfg 226 Transfer complete FTP 87 byte s received in 0 132 second...

Page 70: ...ice port Port number of the remote FTP server in the range of 0 to 65535 The default value is 21 Description Use the open command to log in to the IPv4 FTP server under FTP client view At login enter the username and password If your input is correct the login succeeds If you have logged in to the IPv4 FTP server you cannot use the open command to log in to another server To do so you must disconn...

Page 71: ... specified output interface has a link local address For the configuration of link local addresses see Layer 3 IP Services Configuration Guide Description Use the open ipv6 command to log in to the IPv6 FTP server in FTP client view At login enter the username and password for accessing the FTP server If your input is correct the login succeeds Related commands close Examples Log in to the FTP ser...

Page 72: ...on put Syntax put localfile remotefile View FTP client view Default level 3 Manage level Parameters localfile Name of the local file to be uploaded remotefile File name used after a file is uploaded and saved on the FTP server Description Use the put command to upload a file on the client to the remote FTP server By default if no name is assigned to the file to be saved on the FTP server the name ...

Page 73: ...e slot number of the standby MPU is 1 to the remote FTP server and save it as ftpclienta cfg ftp put chassis2 slot1 flash a cfg ftpclienta cfg 227 Entering Passive Mode 192 168 1 46 4 52 125 ASCII mode data connection already open transfer starting for ftpclienta cfg 226 Transfer complete FTP 1226 byte s sent in 0 065 second s 18 00Kbyte s sec pwd Syntax pwd View FTP client view Default level 3 Ma...

Page 74: ...he remotehelp command to display the help information of FTP related commands supported by the remote FTP server If no argument is specified FTP related commands supported by the remote FTP server are displayed Examples Display FTP commands supported by the remote FTP server ftp remotehelp 214 Here is a list of available ftp commands Those with are not yet implemented USER PASS ACCT CWD CDUP SMNT ...

Page 75: ...er PASV Passive mode TYPE Request type STRU File structure MODE Transmission mode RETR Download a file STOR Upload a file STOU Store unique APPE Appended file ALLO Allocation space REST Restart RNFR Rename the source RNTO Rename the destination ABOR Abort the transmission DELE Delete a file RMD Delete a folder MKD Create a folder PWD Print working directory LIST List files NLST List file descripti...

Page 76: ...ameters directory Directory name on the remote FTP server Description Use the rmdir command to remove a specified directory from the FTP server NOTE Only authorized users are allowed to use this command Delete all files and subdirectories under a directory before you delete the directory For how to delete files see the delete command When you execute the rmdir command the files in the remote recyc...

Page 77: ...ust configure the corresponding username and password on the FTP server or the login will fail and the FTP connection will close Examples User ftp1 has logged in to the FTP server Use username ftp2 to log in to the current FTP server Suppose username ftp2 and password 123123123123 have been configured on the FTP server Method 1 ftp user ftp2 331 Password required for ftp2 Password 230 User logged ...

Page 78: ...on Disable display of detailed prompt information and perform a Get operation ftp undo verbose FTP verbose is off ftp get startup cfg bb cfg FTP 3608 byte s received in 0 052 second s 69 00K byte s sec ftp Enable display of detailed prompt information and perform a Get operation ftp verbose FTP verbose is on ftp get startup cfg aa cfg 227 Entering Passive Mode 192 168 1 46 5 85 125 ASCII mode data...

Page 79: ...on regular expression Specifies a regular expression a case sensitive string of 1 to 256 characters Description Use the display tftp client configuration command to display source IP address configuration of the TFTP client Related commands tftp client source Examples Display the source IP address configuration of the TFTP client Sysname display tftp client configuration The source IP address is 1...

Page 80: ... 1 only in the IPv4 networking environment Sysname system view Sysname acl number 2000 Sysname acl basic 2000 rule permit source 1 1 1 1 0 Sysname acl basic 2000 quit Sysname tftp server acl 2000 Allow the device to access the TFTP server with the IP address of 2001 1 only in the IPv6 networking environment Sysname system view Sysname acl ipv6 number 2001 Sysname acl6 basic 2001 rule permit source...

Page 81: ...to both the root directory on the flash of the active MPU and the root directory on the flash of the standby MPU Sysname tftp 192 168 1 26 get newest app startup app File will be transferred in binary mode Downloading file from remote TFTP server please wait TFTP 2737556 bytes received in 13 second s File downloaded successfully Download the file from the TFTP server to the root directory on the f...

Page 82: ...stablished ip source ip address Specifies the source IP address of packets sent to a TFTP server which is one of the IP addresses configured on the device Description Use the tftp client source command to specify the source IP address of packets sent to a TFTP server Use the undo tftp client source command to restore the default By default the source IP address is the IP address of the output inte...

Page 83: ... link local address For the configuration of a link local address see IPv6 basics configuration in the Layer 3 IP Services Configuration Guide get Downloads a file put Uploads a file source file Source filename destination file Destination filename If it is not specified this filename is the same as the source filename vpn instance vpn instance name Specifies the MPLS L3 VPN that the TFTP server b...

Page 84: ...s the root directory or if no upper directory exists the current working directory does not change when the cd command is executed This argument does not support command online help Returns to the root directory of the storage medium This keyword does not support command line online help Description Use the cd command to change the current working directory Examples Enter the test folder after log...

Page 85: ...irf Switch Slot Role Priority CPU Mac 1 0 Slave 20 00e0 fc0f 8c0f 1 1 Slave 20 00e0 fc0f 8c1f 2 0 Master 20 00e0 fc0f 8c22 2 1 Slave 20 00e0 fc0f 8c32 indicates the device is the master indicates the device through which the user logs in The Bridge MAC of the IRF is 00e0 fc00 0a00 Auto upgrade yes Mac persistent 6 min The output shows that MPU 0 on member switch 2 is the active MPU of the IRF fabr...

Page 86: ...h vrcfg cfg Done 2 In IRF mode Copy the configuration file of the active MPU of the IRF fabric to the root directory of a standby MPU the member ID and the slot number of the member switch where the standby MPU resides are both 1 of the IRF fabric Sysname copy vrcfg cfg chassis1 slot1 flash Copy flash vrcfg cfg to chassis1 slot1 flash vrcfg cfg Y N y Copy file flash vrcfg cfg to chassis1 slot1 fla...

Page 87: ...n Use the delete unreserved file url command to permanently delete a file and the deleted file cannot be restored Use it with caution CAUTION If you delete two files with the same filename in different directories only the last one is retained in the recycle bin Examples 1 In standalone mode Remove file tt cfg from the root directory of the storage medium on the active MPU Sysname delete tt cfg De...

Page 88: ...idden files hidden folders files moved from the current directory to the recycle bin Files in the recycle bin are enclosed in square brackets file url Displays the specified file Asterisks are acceptable as wildcards For example to display files with the txt extension in the current directory you may use the dir txt command all filesystems Displays files and folders in the root directory of all st...

Page 89: ...our switch model Sysname dir all filesystems Directory of flash 0 rw 8198 Nov 19 2010 11 37 13 startup cfg 1 rw 7228 Mar 31 2011 11 19 33 song cfg 2 rw 151 Mar 31 2011 11 19 27 system xml 3 drw May 05 2010 15 23 04 seclog 4 rw 438156 Jun 12 2010 09 17 31 empua1 btw 5 rw 27695177 Mar 22 2011 14 56 46 main app 6 drw Sep 03 2010 11 06 09 patch6613 7 rw 429516 Aug 20 2010 09 42 41 mpu btw 8 rw 7228 Ja...

Page 90: ...pr 26 2011 12 02 05 snmpboots 1 rw 10187730 Apr 26 2011 16 47 07 startup app 2 rwh 3144 Apr 26 2011 13 45 35 private data txt 3 rw 2161 Apr 26 2011 13 53 25 startup cfg 4 rw 10058752 Sep 19 2011 17 41 46 startup_b app 5 rw 10139143 Apr 26 2011 13 08 20 startup_backup app 6 rwh 716 Apr 26 2011 12 01 58 hostkey 7 rwh 572 Apr 26 2011 12 02 11 serverkey 8 rwh 548 Apr 26 2011 12 02 17 dsakey 9 rw 3035 ...

Page 91: ...up cfg 2 rw 124 Apr 26 2011 12 00 22 patchstate 3 rwh 716 Apr 26 2011 14 31 36 hostkey 4 rwh 4 Apr 26 2011 14 31 41 snmpboots 5 rw 10187730 Apr 26 2011 12 01 10 startup app 6 rwh 572 Apr 26 2011 14 31 47 serverkey 7 rwh 548 Apr 26 2011 14 31 52 dsakey 8 rw 3035 Apr 26 2011 13 45 36 new config cfg 9 drw Apr 26 2011 12 11 53 oldver 64389 KB total 11839 KB free Method 2 Sysname cd chassis1 slot1 flas...

Page 92: ...ne files Executing a batch file is to execute a set of command lines in the file Do not include invisible characters in a batch file If an invisible character is found during the execution the batch process will abort and the commands that have been executed cannot be cancelled Not every command in a batch file is sure to be executed For example if a certain command is not correctly configured the...

Page 93: ...t which is recommended to avoid mis operations When the prompt mode is set to quiet the system does not warn for any file operation Examples Set the file operation prompt mode to alert Sysname system view Sysname file prompt alert fixdisk Syntax fixdisk device View User view Default level 3 Manage level Parameters device Storage medium name Description Use the fixdisk command to restore the space ...

Page 94: ...ription Use the format command to format a storage medium CAUTION Formatting a storage medium results in loss of all the files on the storage medium and these files cannot be restored In particular if a startup configuration file exists on a storage medium formatting the storage medium results in loss of the startup configuration file Examples Format the flash Sysname format flash All data on flas...

Page 95: ...In standalone mode Create folder test on the standby MPU in slot 1 Sysname mkdir slot1 flash test Created dir slot1 flash test 2 In IRF mode Create folder test on the active MPU of the IRF fabric Sysname mkdir test Created dir flash test1 Create folder test on a standby MPU the member ID and slot number of the member switch where the standby MPU resides are 2 and 1 respectively of the IRF fabric S...

Page 96: ...lone mode Display the contents of file testcfg cfg on the standby MPU Sysname more slot1 flash testcfg cfg version 5 20 Release 0000 sysname Test More 2 In IRF mode Display the contents of file testcfg cfg on the active MPU of the IRF fabric Sysname more testcfg cfg version 5 20 Release 0000 sysname Sysname More Display the contents of file testcfg cfg on a standby MPU the member ID and slot numbe...

Page 97: ...ocessing files on the storage medium Otherwise the file system could be damaged When a storage medium is connected to a lower version system the system may not be able to recognize the device automatically and you need to use the mount command for the storage medium to function normally Before removing a mounted storage medium from the system you should first unmount it to avoid damaging the devic...

Page 98: ...me of the source file fileurl dest Name of the target file or folder Description Use the move command to move a file If you specify a target folder the system will move the source file to the specified folder with the file name unchanged You cannot move files between storage media of different types Examples Move file flash test sample txt to flash and save it as 1 txt Sysname move test sample txt...

Page 99: ...arameters fileurl source Name of the source file or folder fileurl dest Name of the target file or folder Description Use the rename command to rename a file or folder The target file name must be unique in the current path Examples Rename file sample txt as sample bat Sysname rename sample txt sample bat Rename flash sample txt to flash sample bat Y N y Renamed file flash sample txt to flash samp...

Page 100: ...iginal directory of the file and then execute the reset recycle bin command Examples Delete file b cfg in the current directory and in the recycle bin Display all the files in the recycle bin and in the current directory Sysname dir all Directory of flash 0 rwh 3080 Apr 26 2011 16 41 43 private data txt 1 rw 2416 Apr 26 2011 13 45 36 config cfg 2 rw 8036197 May 14 2011 10 13 18 main app 3 rw 2386 ...

Page 101: ...tory test and in the recycle bin Enter the subdirectory Sysname cd test Check all the files in the subfolder test Sysname dir all Directory of flash test 0 rw 2161 Apr 26 2011 21 22 35 aa cfg 64389 KB total 16734 KB free The output shows that only one file exists in the folder and the file has been moved to the recycle bin Permanently delete file test aa cfg Sysname reset recycle bin Clear flash t...

Page 102: ...ed state By default a storage medium is automatically mounted and in the mounted state You need to unmount it before removing it from the device When mounting or unmounting a storage medium or performing file operations on it do not unplug or switchover the storage medium or the card where the storage medium resides Otherwise the file system could be damaged When a storage medium is connected to a...

Page 103: ...cf umounted from chassis 2 slot 1 undelete Syntax undelete file url View User view Default level 3 Manage level Parameters file url Name of the file to be restored Description Use the undelete command to restore a file from the recycle bin If another file with the same name exists in the same path the system prompts you whether to overwrite the original file Examples Restore file a cfg in director...

Page 104: ...97 Sysname cd test Sysname undelete b cfg Undelete flash test b cfg Y N y Undeleted file flash test b cfg ...

Page 105: ... When you execute the archive configuration command the running configuration is only saved to the active MPU and the standby MPU does not perform the saving operation In standalone mode When you execute the archive configuration command the running configuration is only saved to the active MPU of the IRF fabric and the other MPUs of the IRF fabric do not perform the saving operation In IRF mode E...

Page 106: ...nfiguration of the device changes frequently HP recommends that you set a shorter saving interval Before executing the archive configuration interval command you must configure the filename prefix and path for saving configuration files by using the archive configuration location command When you execute the archive configuration interval command the running configuration is only saved to the acti...

Page 107: ...aving and rollback operations are executed only on the active MPU After the active standby switchover the configuration rollback can take effect on the new active MPU The archive configuration location command configures the path and filename prefix for saving configuration files on both the active MPU and standby MPU Before executing this command verify that the path is available on both the acti...

Page 108: ...ved in the range of 1 to 10 The value of the file number argument is determined by the memory space HP recommends that you set a comparatively small value for this argument if the available memory space is small Description Use the archive configuration max command to set the maximum number of configuration files that can be saved Use the undo archive configuration max command to restore the defau...

Page 109: ... level 2 System level Parameters dest addr IP address or name of a TFTP server The address cannot be an IPv6 address dest filename Target filename used to save the startup configuration file on the server Description Use the backup startup configuration command to back up the startup configuration file to a specified TFTP server If you do not specify this filename the original filename is used The...

Page 110: ...w replacing the current configuration Please wait Info Succeeded in replacing current configuration with the file my_archive_1 cfg display archive configuration Syntax display archive configuration begin exclude include regular expression View Any view Default level 1 Monitor level Parameters Filters command output by specifying a regular expression For more information about regular expressions s...

Page 111: ...ration configuration configuration interface interface type interface number exclude modules by linenum begin exclude include regular expression View Any view Default level 2 System level Parameters configuration configuration Displays a non interface configuration If the argument is not provided all the non interface configuration is displayed If parameters are used display the specified informat...

Page 112: ... 1 1 1 1 1 1 255 255 255 255 is displayed meaning the validated subnet mask is 32 bits Related commands display saved configuration reset saved configuration and save Examples Display the configuration from the line containing user interface to the last line in the current configuration the output information depends on the current configuration Sysname display current configuration begin user int...

Page 113: ...and to verify that important configurations are saved to the startup configuration file If the system is not specified with a startup configuration file or the specified configuration file does not exist the display saved configuration command displays the default configuration file of the device If the default configuration file does not exist the system prompts The config file does not exist Rel...

Page 114: ...99 15 16 domain system 17 access limit disable 18 state active 19 idle cut disable 20 self service url disable 21 22 interface NULL0 23 More The More prompt indicates that there are more line that the screen can display Pressing Enter displays the next line pressing Space displays the next screen pressing Ctrl C or any other key exits the display display startup Syntax display startup begin exclud...

Page 115: ...and the one to be used at the next system startup Sysname display startup MainBoard Current startup saved configuration file flash startup cfg Next startup saved configuration file flash startup cfg Slot 1 Current startup saved configuration file flash startup cfg Next startup saved configuration file flash startup cfg Table 10 Output description Field Description MainBoard Configuration files use...

Page 116: ...y linenum begin exclude include regular expression View Any view Default level 1 Monitor level Parameters by linenum Displays the number of each line Filters command output by specifying a regular expression For more information about regular expressions see Fundamentals Configuration Guide begin Displays the first line that matches the specified regular expression and all lines that follow exclud...

Page 117: ...e valid configuration information of all user interfaces the output information depends on the current configuration of the device Sysname system view Sysname user interface vty 0 Sysname ui vty0 display this user interface aux 0 user interface vty 0 history command max size 256 user interface vty 1 15 return reset saved configuration Syntax reset saved configuration View User view Default level 3...

Page 118: ...rom the storage media of the device Sysname reset saved configuration The saved configuration file will be erased Are you sure Y N y Configuration file in flash is being cleared Please wait MainBoard Configuration file is cleared Chassis 1 Slot 1 Erase next configuration file successfully restore startup configuration Syntax restore startup configuration from src addr src filename View User view D...

Page 119: ...e the existing file or not Both the active MPU and a standby MPU of the IRF fabric use the storage media of the same type when the device is checking the filename or backing up the configuration file to the standby MPU When backing up the configuration file to the standby MPU the device saves the file to the same directory on the standby MPU as on the active MPU that is the root directory If the s...

Page 120: ...rm your operation If you do no confirm your operation within 30 seconds the system automatically quits the operation If you provide the force keyword when executing the save command the system directly saves the current configuration not requiring any confirmation Description In standalone mode Use the save file url all slot slot number command to save the configuration to the specified configurat...

Page 121: ...configuration file flash bb cfg Slot 1 Current startup saved configuration file flash startup cfg Next startup saved configuration file flash bb cfg The output shows that the startup configuration file for both the active MPU and standby MPU is bb cfg Sysname save The current configuration will be written to the device Are you sure Y N y Please input the file name cfg flash bb cfg To leave the exi...

Page 122: ...ch 1 Sysname save test cfg chassis 2 slot 1 The current configuration will be saved to chassis2 slot1 flash test cfg Continue Y N y Now saving current configuration to the device Saving configuration chassis2 slot1 flash test cfg Please wait Configuration is saved to chassis2 slot1 flash successfully Or use the following command approach 2 Sysname save chassis2 slot1 flash test cfg Save the config...

Page 123: ...ctory configuration In standalone mode Use the startup saved configuration command to specify a startup configuration file for each MPU of the IRF fabric In IRF mode Use the undo startup saved configuration command to configure all the MPUs to start up with the null factory configuration In IRF mode The startup configuration file of the active MPU and standby MPU must be the same Before using the ...

Page 124: ...e master board Done Setting the slave board Slot 1 Set next configuration file successful 2 In IRF mode Specify a startup configuration file Sysname startup saved configuration testcfg cfg Please wait Setting the master board Done Setting the slave board Chassis 2 Slot 1 Set next configuration file successfully ...

Page 125: ...uffix slot slot number Specifies the slot number of a card In standalone mode all Specifies a file as the system software image at the next boot for all member switches of an IRF fabric slot number Specifies a file as the system software image at the next boot for a member switch The slot number argument is the ID of a member switch of the current IRF fabric chassis chassis number slot slot number...

Page 126: ...name such as flash If the storage media is on the standby MPU of the IRF fabric any MPUs except the active MPU of the IRF fabric specify the storage media by giving its device ID and the slot number of the card in the format of chassischassis number slotslot number such as chassis2 slot1 flash When you specify the system software image for the next boot of the active MPU of the IRF fabric the file...

Page 127: ...storage media of card Otherwise the system prompts error and the execution of the command fails In IRF mode Sysname boot loader file chassis1 slot1 flash test app chassis 1 slot 1 main This command will set the boot file of the specified board Continue Y N y The specified file will be used as the main boot file at the next reboot on chassis 1 slot 1 bootrom Syntax In standalone mode bootrom backup...

Page 128: ...estore back up or upgrade Boot ROM on a specified card To upgrade Boot ROM for an MPU first save the corresponding Boot ROM image under the root directory of the storage media on the MPU To upgrade Boot ROM for a line processing unit LPU first save the Boot ROM image under the root directory of the storage media on the active MPU When you upgrade Boot ROM for the active MPU or an LPU the file url ...

Page 129: ...slot 1 Use the a btw file to upgrade Boot ROM on the global active MPU in slot 0 of the device with member ID of 2 The output of this command varies with devices In IRF mode Sysname bootrom update file a btw chassis 1 slot 0 This command will update bootrom file on the specified board s Continue Y N y Now updating bootrom please wait Start accessing bootflash chip Attention don t power down device...

Page 130: ... member switch The chassis number argument is the ID of a member switch of the current IRF fabric If you do not provide this argument all the member switches are specified In IRF mode slot slot number Specifies the slot number of the card If you do not provide the argument all the MPUs are specified In IRF mode Filters command output by specifying a regular expression For more information about re...

Page 131: ... file adopted for the current and next boot of the device In IRF mode Sysname display boot loader The primary app to boot of chassis 1 board 0 at this time is flash test app The primary app to boot of chassis 1 board 0 at next time is flash test app The slave app to boot of chassis 1 board 0 at next time is flash test app The primary app to boot of chassis 2 board 0 at this time is flash test app ...

Page 132: ...output of this command varies with devices in standalone mode Sysname display patch The following patch packages are loaded flash patch package app Package Version 001 loaded on slot s 0 1 2 3 4 5 Display the installed patch files and the versions of their corresponding patch packages The output of this command varies with devices in IRF mode Sysname display patch The following patch packages are ...

Page 133: ...0a68e1c 4 LPU 0 0 0 0 0 0x8568c8f8 5 LPU 0 0 0 0 0 0x8568c8f8 In standalone mode display hotfix information Sysname display patch information The location of patches flash Chassis Slot Version Temporary Common Current Active Running Start Address 1 0 MPU 0 0 0 0 0 0x84c94e60 1 3 LPU 0 0 0 0 0 0x8568c8f8 1 3 1 LPO 0 0 0 0 0 0x80a68e1c 1 4 LPU 0 0 0 0 0 0x8568c8f8 1 5 LPU 0 0 0 0 0 0x8568c8f8 Table ...

Page 134: ...tandalone mode chassis chassis number slot slot number Specifies a card on an IRF member switch The chassis number argument refers to the ID of the IRF member switch and the slot number argument refers to the number of the slot where the card resides in IRF mode Description Use the patch active command to activate patches The system will temporarily run the loaded patches If you execute the comman...

Page 135: ...ch number chassis chassis number slot slot number View System view Default level 3 Manage level Parameters patch number Sequence number of a patch with values depending on the patch file used slot slot number Specifies a card by its slot number In standalone mode chassis chassis number slot slot number Specifies a card on an IRF member switch The chassis number argument refers to the ID of the IRF...

Page 136: ...r slot slot number View System view Default level 3 Manage level Parameters patch number Sequence number of a patch with values depending on the patch file used slot slot number Specifies a card by its slot number In standalone mode chassis chassis number slot slot number Specifies on an IRF member switch The chassis number argument refers to the ID of the IRF member switch and the slot number arg...

Page 137: ...s It specifies the directory where the patch file locates and must be a root directory of a storage media Provide this argument when you install a patch file which is not packaged in a patch package file The provided patch file name must be valid Otherwise the system cannot locate the patch file and the hotfixing operation fails file filename Filename of a patch package Provide this option when yo...

Page 138: ...nd varies with devices Sysname system view Sysname patch install flash Patches will be installed Continue Y N y Do you want to run patches after reboot Y N y Installing patches Install the specified patch package The output of this command varies with devices Sysname system view Sysname patch install file patch_packeg bin Patches will be installed Continue Y N y Do you want to run patches after re...

Page 139: ...tch packages to any directory on the active MPU of the IRF fabric In IRF mode if you load patches form patch files save the patch files to root directories of the member switches storage media save the patch files for the active MPU or LPUs of each member switch to the root directory of the Flash on the local active MPU and save the patch files for the standby MPUs of each member switch to the Fla...

Page 140: ...t slot number Specifies a card by its slot number In standalone mode chassis chassis number slot slot number Specifies a card on an IRF member switch The chassis number argument refers to the ID of the IRF member switch and the slot number argument refers to the number of the slot where the card resides In IRF mode Description Use the patch run command to confirm the running of ACTIVE patches If y...

Page 141: ... Examples In standalone mode confirm the running of patch 3 and all the ACTIVE patches before patch 3 on the standby MPU in slot 1 Sysname system view Sysname patch run 3 slot 1 In standalone mode confirm the running of all the ACTIVE patches on the standby MPU in slot 1 Sysname system view Sysname patch run slot 1 In IRF mode confirm the running of patch 3 and all the ACTIVE patches before patch ...

Page 142: ...f 1 to 256 characters Description Use the display issu rollback timer command to display information about the rollback timer NOTE Since the rollback timer takes effect in the next ISSU upgrade process The remaining time of the rollback timer may be greater than the rollback timer value Related commands issu rollback timer Examples Display the current setting and remaining time of the rollback tim...

Page 143: ...fied regular expression regular expression Specifies a regular expression a case sensitive string of 1 to 256 characters Description Use the display issu state command to display the ISSU state NOTE The ISSU upgrade process executes commands in a specific sequence With the display issu state command you can view the current ISSU state upgrade version old version version compatibility state and upg...

Page 144: ... are available in the system and at least one standby MPU has not been upgraded to the new version In this state neither manual nor auto rollback will be performed Compatibility Version compatibility check results Compatible The fundamental modules that support the operation of the switch and the service modules are compatible The ISSU upgrade between the two versions can proceed Incompatible The ...

Page 145: ...th a string of 1 to 63 characters If you enter a relative path the system automatically converts it to an absolute path The absolute path can contain no more than 63 characters Filters command output by specifying a regular expression For more information about regular expressions see Fundamentals Configuration Guide begin Displays the first line that matches the specified regular expression and a...

Page 146: ...tware version and A7500 app after executing the issu load command Sysname display version comp matrix file A7500 app Number of Matrices in Table 1 Matrix for HP A7503 Running Version 6606L07 Version Compatibility List 6606L07 Compatible chassis 0 slot 2 Hotfix chassis 0 slot 5 Hotfix chassis 0 slot 6 Hotfix In IRF mode view the version compatibility information between the current software version...

Page 147: ...ng the corresponding hotfix and the ISSU upgrade will not interrupt the services on the LPU issu accept Syntax In standalone mode issu accept slot slot number In IRF mode issu accept chassis chassis number issu accept chassis chassis number slot slot number View System view Default level 2 System level Parameters slot slot number Specifies the slot number of an upgraded MPU The value must be the s...

Page 148: ...m deletes the rollback timer and does not perform the auto rollback operation in this upgrade process However you can execute a manual rollback at the Command Line Interface CLI Execution of the issu accept command is the third step in the ISSU upgrade process You can use this command as an option Use the issu commit command to complete the upgrade process Related commands issu load and issu commi...

Page 149: ...s number command to upgrade the MPU that is not upgraded Use this command when you apply the member switch based ISSU upgrade method Use the issu commit chassis chassis number slot slot number command to upgrade the MPU that is not upgraded Use this command when you apply the MPU based ISSU upgrade method NOTE Executing of the issu commit command is the fourth step in the ISSU upgrade process Exec...

Page 150: ...it to an absolute path The absolute path can contain no more than 63 characters The file name is in the format of drive file name where the following conditions apply The items in square brackets are optional drive specifies the storage medium of the file The value is the name of the storage medium If a switch has only one storage media execute this command without providing this argument file nam...

Page 151: ...tandby MPU is in a real time backup state which you can display with the display switchover state command With incompatible versions save the configuration to the active MPU and standby MPU with the save command To avoid upgrade failure do not modify the configuration reboot a card perform an active and standby switchover delete or modify the system software image or load or unload a hotfix during...

Page 152: ... or unload a hotfix during the ISSU upgrade Examples In the ISSU upgrade process in standalone mode upgrade the standby MPU in slot 1 with upgrade file new app which is basic level compatible with the current running system software image Sysname system view Sysname issu load file new app slot 1 This command will begin ISSU and the specified board will reboot and be upgraded Please save the curren...

Page 153: ... the issu rollback command to cancel the ISSU upgrade and the configuration will automatically roll back to the previous version NOTE During the execution of any issu command you cannot perform the roll back operation Before executing the issu load command or after executing the issu commit command you cannot perform the roll back operation Related commands issu load Examples Suppose that the slot...

Page 154: ...ates that the version rollback function is disabled and the rollback timer is not created when you execute the issu load command Description Use the issu rollback timer command to set the rollback timer value Use the undo issu rollback timer command to restore the default By default the rollback timer value is 45 minutes NOTE With the issu load command executed the system automatically creates a v...

Page 155: ...ions executing the issu run switchover command is the second step in the ISSU upgrade process After you execute the issu run switchover command these are the results The active MPU reboots with the previous version The upgraded standby MPU that is specified at the CLI becomes the active MPU The system upgrades all LPUs by installing hotfixes For LPUs that have no upgrade hotfixes or do not support...

Page 156: ...mmand the master reboots with the new version and the ISSU upgrade process is completed after that If you do not execute the issu accept or issu commit command before the specified rollback timer expires the system automatically stops the ISSU process and reverts to the previous software version Avoid configuring the system performing an active and standby switchover and plugging unplugging a card...

Page 157: ...150 Sysname issu run switchover chassis 1 slot 1 Master will reboot switch the specified board to master and update the line card Continue Y N y ...

Page 158: ...Use the clock datetime command to set the current time and date of the device You can leave the SS field when you specify the time parameters Related commands display clock clock summer time one off clock summer time repeating and clock timezone Examples Set the current system time to 14 10 20 08 01 201 1 Sysname clock datetime 14 10 20 8 1 2011 Set the current system time to 00 06 00 01 01 201 1 ...

Page 159: ... time value automatically adds to the system time To verify the setting use the display clock command The timestamps in system messages are adjusted in reference to the time zone and daylight saving schedule Related commands display clock clock datetime clock summer time repeating and clock timezone Examples Set the system time ahead one hour for the period between 06 00 00 on 08 01 201 1 and 06 0...

Page 160: ...et a recurring daylight saving schedule Use the undo clock summer time command to cancel the configuration of daylight saving time By default daylight saving time is disabled and UTC time zone applies The interval between start time start date and end time end date must be longer than one day and shorter than one year If the current system time is in the specified daylight saving days the add time...

Page 161: ...e and daylight saving schedule Related commands display clock clock datetime clock summer time one off and clock summer time repeating Examples Set the local time zone to add five hours to UTC time Sysname system view Sysname clock timezone z5 add 5 copyright info enable Syntax copyright info enable undo copyright info enable View System view Default level 3 Manage level Parameters None Descriptio...

Page 162: ...ble Please press ENTER Disable displaying the copyright statement Sysname system view Sysname undo copyright info enable When a Telnet user logs in the user view prompt appears Sysname When a console user quits user view the following message appears User interface aux0 is available Please press ENTER display alarm Syntax In standalone mode display alarm slot slot number begin exclude include regu...

Page 163: ...ression include Displays all lines that match the specified regular expression regular expression Specifies a regular expression a case sensitive string of 1 to 256 characters Description Use the display alarm command to display alarms present on cards Examples In standalone mode display alarms present on any card Sysname display alarm Slot Level Info 0 INFO Power 2 is absent 0 ERROR The board in ...

Page 164: ... current time and date Sysname display clock 09 41 23 UTC Thu 12 15 2010 display cpu usage Syntax In standalone mode display cpu usage slot slot number cpu cpu number begin exclude include regular expression display cpu usage entry number offset verbose slot slot number cpu cpu number begin exclude include regular expression In IRF mode display cpu usage chassis chassis number slot slot number cpu...

Page 165: ...by specifying a regular expression For more information about regular expressions see the Fundamentals Configuration Guide begin Displays the first line that matches the specified regular expression and all lines that follow exclude Displays all lines that do not match the specified regular expression include Displays all lines that match the specified regular expression regular expression Specifi...

Page 166: ...th and sixth CPU usage statistics records Sysname display cpu usage 2 4 CPU usage info no 0 idx 58 CPU Usage Stat Cycle 60 Second CPU Usage 3 CPU Usage Stat Time 2010 07 10 10 56 55 CPU Usage Stat Tick 0x1d9d CPU Tick High 0x3a659a70 CPU Tick Low Actual Stat Cycle 0x0 CPU Tick High 0x95030517 CPU Tick Low CPU usage info no 1 idx 57 CPU Usage Stat Cycle 60 Second CPU Usage 3 CPU Usage Stat Time 201...

Page 167: ...le CPU usage measurement interval in seconds For example if the value is 41 it indicates that the average CPU usage during the last 41 seconds is calculated The value range of this field is 1 to 60 CPU Usage Average CPU usage in a measurement interval in percentage CPU Usage Stat Time CPU usage statistics time in seconds that is the system time when the command is executed CPU Usage Stat Tick Syst...

Page 168: ...by specifying a regular expression For more information about regular expressions see Fundamentals Configuration Guide begin Displays the first line that matches the specified regular expression and all lines that follow exclude Displays all lines that do not match the specified regular expression include Displays all lines that match the specified regular expression regular expression Specifies a...

Page 169: ...STEM in the last 60 minutes 5 12 minutes ago 10 13 minutes ago 15 14 minutes ago 10 15 minutes ago 5 16 and 17 minutes ago 10 18 minutes ago 5 19 minutes ago 2 or lower than 2 other time Display the CPU usage statistics for task 6 Sysname display cpu usage history task 6 100 95 90 85 80 75 70 65 60 55 50 45 40 35 30 25 20 15 10 5 10 20 30 40 50 60 minutes ...

Page 170: ...etailed information Filters command output by specifying a regular expression For more information about regular expressions see the Fundamentals Configuration Guide begin Displays the first line that matches the specified regular expression and all lines that follow exclude Displays all lines that do not match the specified regular expression include Displays all lines that match the specified re...

Page 171: ...tch Ver 1 0 LSQ1SRP1CB Master 0 A7500 6626 None 1 1 NONE Absent 0 NONE None 1 2 LSQ1TGX2SD Normal 0 A7500 6626 None 1 3 NONE Absent 0 NONE None 1 4 LSQ1FV48SA Normal 0 A7500 6626 None 2 0 LSQ1SRP2XB Slave 0 A7500 6626 None 2 1 LSQ1SRP2XB Slave 0 A7500 6626 None 2 2 LSQ1FV48SA Normal 0 A7500 6626 None 2 3 LSQ1FV48SA Normal 0 A7500 6626 None 2 4 LSQ1TGX2SD Normal 0 A7500 6626 None 2 5 SRP2XBSLAVE No...

Page 172: ...label data for an IRF member switch The chassis number argument represents the IRF member ID of the switch If no member switch is specified the command displays the electronic label data for all member switches In IRF mode slot slot number Displays the electronic label data for a card The slot number argument represents the slot number of the card If no card is specified the command displays the e...

Page 173: ...MANUFACTURING_DATE 2010 11 10 VENDOR_NAME HP Slot 2 DEVICE_NAME HP A7500 48 port Gig T PoE upg SA Mod JD199C DEVICE_SERIAL_NUMBER CN12D4W789 MAC_ADDRESS NONE MANUFACTURING_DATE 2011 2 2 VENDOR_NAME HP In IRF mode display the electronic label data for all IRF member switches Sysname display device manuinfo Chassis 1 Slot 0 DEVICE_NAME HP A7500 384Gbps Fab MPU w 2p 10 GbE XFP JD193B DEVICE_SERIAL_NU...

Page 174: ... or troubleshooting you can use separate display commands to collect running status data module by module or use the display diagnostic information command to bulk collect running data for multiple modules The display diagnostic information command equals this set of commands display clock display version display device and display current configuration Examples Save each module s running status d...

Page 175: ...l lines that do not match the specified regular expression include Displays all lines that match the specified regular expression regular expression Specifies a regular expression a case sensitive string of 1 to 256 characters Description Use the display environment command to display temperature information including the current temperature and temperature thresholds In standalone mode if no card...

Page 176: ...or hotspot A hotspot sensor Temperature Current temperature Lower Temperature lower limit Warning Warning temperature threshold Alarm Alarming temperature threshold Shutdown Shut down temperature threshold When the sensor temperature reaches this limit the system automatically shuts down display fan Syntax In standalone mode display fan fan id begin exclude include regular expression In IRF mode d...

Page 177: ...ession a case sensitive string of 1 to 256 characters Description Use the display fan command to display the operating state of fan trays Examples In standalone mode display the operating state of all fan trays Sysname display fan Fan 1 State Normal In IRF mode display the operating state of all fan trays in the IRF fabric Sysname display fan Chassis 1 Fan 1 State Normal Chassis 2 Fan 1 State Norm...

Page 178: ...d commands job time and view Examples Display detailed information about the scheduled job saveconfig Sysname display job saveconfig Job name saveconfig Specified view monitor Time 1 Execute command save 1 cfg after 40 minutes The output shows that the current configuration will be automatically saved to the configuration file 1 cfg in 40 minutes Table 24 Output description Field Description Job n...

Page 179: ...exclude Displays all lines that do not match the specified regular expression include Displays all lines that match the specified regular expression regular expression Specifies a regular expression a case sensitive string of 1 to 256 characters Description Use the display memory command to display memory usage statistics 1 In standalone mode If no card is specified this command displays the memor...

Page 180: ...ay OEM information Sysname display oem Current OEMs Slot 1 H3C Slot 2 HP New OEMs Slot 1 HP Slot 2 HP In IRF mode display OEM information Sysname display oem Current OEMs Chassis 1 Slot 0 H3C Chassis 1 Slot 1 HP Chassis 2 Slot 0 HP Chassis 2 Slot 1 H3C New OEMs Chassis 1 Slot 0 HP Chassis 1 Slot 1 HP Chassis 2 Slot 0 HP Chassis 2 Slot 1 HP display power Syntax In standalone mode display power powe...

Page 181: ...ys the first line that matches the specified regular expression and all lines that follow exclude Displays all lines that do not match the specified regular expression include Displays all lines that match the specified regular expression regular expression Specifies a regular expression a case sensitive string of 1 to 256 characters Description Use the display power command to display power suppl...

Page 182: ...edule job command to display the job configured by using the schedule job command Related commands schedule job Examples Display the job configured by using the schedule job command Sysname display schedule job Specified command execute 1 bat Specified view system view Executed time at 12 00 10 31 2011 in 0 hours and 16 minutes If you change the system time within 16 minutes after you execute the ...

Page 183: ...es Display the reboot schedule Sysname display schedule reboot System will reboot at 16 00 00 03 10 2010 in 2 hours and 5 minutes display switch mode status Syntax In standalone mode display switch mode status begin exclude include regular expression In IRF mode display switch mode status chassis chassis number begin exclude include regular expression View Any view Default level 0 Visit level Para...

Page 184: ...ll cards on the member switch Sysname display switch mode status chassis 1 Slot No Switch Mode 0 STANDARD ROUTING 3 MIX BRIDGING ROUTING 4 MIX BRIDGING ROUTING Table 27 Output description Field Description Slot No Card slot number Switch Mode Operating mode of the card STANDARD Standard operating mode STANDARD ROUTING Standard operating mode with the route extension function STANDARD BRIDGING Stan...

Page 185: ...ception handling method for MPUs Sysname display system failure System failure handling method reboot display transceiver Syntax display transceiver interface interface type interface number begin exclude include regular expression View Any view Default level 2 System level Parameters interface interface type interface number Displays the key parameters of all transceiver modules or the transceive...

Page 186: ...developed by NTT LC 1 25 mm RJ 45 fiber connector developed by Lucent RJ 45 CX 4 Wavelength nm Fiber transceiver central wavelength in nm of the transmit laser If the transceiver supports multiple wavelengths every two wavelength values are separated by a comma Copper transceiver displayed as N A Transfer distance xx Transfer distance with xx representing km for single mode transceiver modules and...

Page 187: ...ude Displays all lines that do not match the specified regular expression include Displays all lines that match the specified regular expression regular expression Specifies a regular expression a case sensitive string of 1 to 256 characters Description Use the display transceiver alarm command to display alarms present on transceiver modules If no error has occurred None is displayed Table 29 des...

Page 188: ...ias current is high TX bias low TX bias current is low TX power high TX power is high TX power low TX power is low Module not ready Module is not ready APD supply fault APD Avalanche Photo Diode supply fault TEC fault TEC Thermoelectric Cooler fault Wavelength unlocked Wavelength of optical signal exceeds the manufacturer s tolerance Temp high Temperature is high Temp low Temperature is low Voltag...

Page 189: ...ue of digital diagnosis parameters of transceivers in all the interfaces Filters command output by specifying a regular expression For more information about regular expressions see Fundamentals Configuration Guide begin Displays the first line that matches the specified regular expression and all lines that follow exclude Displays all lines that do not match the specified regular expression inclu...

Page 190: ...eters interface interface type interface number Displays the electronic label data for the transceiver module in the specified interface or all transceiver modules The interface type interface number arguments specify an interface by its type and number Filters command output by specifying a regular expression For more information about regular expressions see Fundamentals Configuration Guide begi...

Page 191: ...ion For more information about regular expressions see Fundamentals Configuration Guide begin Displays the first line that matches the specified regular expression and all lines that follow exclude Displays all lines that do not match the specified regular expression include Displays all lines that match the specified regular expression regular expression Specifies a regular expression a case sens...

Page 192: ... None Slot 3 Without Board Table 33 Output description Field Description HP Comware Platform Software The system software version of the switch including the software platform name platform version and product release version In the sample output the software platform name is Comware the platform version is 5 20 99 and the product release version is Release 0000 HP A7502 uptime is 0 week 0 day 7 h...

Page 193: ...de begin Displays the first line that matches the specified regular expression and all lines that follow exclude Displays all lines that do not match the specified regular expression include Displays all lines that match the specified regular expression regular expression Specifies a regular expression a case sensitive string of 1 to 256 characters Description Use the display version update record...

Page 194: ...es user view text Banner message which can be input in two formats For more information see Fundamentals Configuration Guide Description Use the header command to create a banner Use the undo header command to clear a banner Banners are greeting or alert messages that the system displays during the login process of a user Examples Configure banners Sysname system view Sysname header incoming Pleas...

Page 195: ...t the owner s prior written consent no decompiling or reverse engineering shall be allowed Welcome to legal header legal Press Y or ENTER to continue N to exit Welcome to motd header motd Welcome to login header login Login authentication Password Welcome to shell header shell Sysname job Syntax job job name undo job job name View System view Default level 3 Manage level Parameters job name Specif...

Page 196: ...ing inter card traffic between the active MPU and the standby MPU Use the undo loadsharing enable command to disable distributing inter card traffic between the active MPU and the standby MPU By default the active MPU and the standby MPU are not load shared and only the active MPU forwards traffic between LPUs NOTE Load sharing is applicable only to unicast traffic The A7502 switch is designed to ...

Page 197: ...he port down function is disabled Examples Enable the port down function globally Sysname system view System View return to User View with Ctrl Z Sysname monitor handshake timeout disable port Open port down function in slot 1 Open port down function in slot 2 Open port down function in slot 3 mmu monitor enable Syntax In standalone mode mmu monitor enable slot slot number undo mmu monitor enable ...

Page 198: ...o all IRF member switches In standalone mode chassis chassis number slot slot number Specifies a card in an IRF member switch The chassis number argument represents the IRF member ID of the switch and the slot number argument represents the slot number of the card If no card is specified the command applies to all IRF member switches In IRF mode Description Use the oem hp command to enable brand m...

Page 199: ... Default level 3 Manage level Parameters chassis chassis number Specifies an IRF member switch The chassis number argument represents the IRF member ID of the switch If no member switch is specified the command reboots all IRF member switches In IRF mode slot slot number Specifies the slot number of a card Description Use the reboot command to reboot a card a switch or an IRF fabric If you are per...

Page 200: ...vel Parameters None Description Use the reset unused porttag command to clear unused 16 bit indexes on every MPU The switch must maintain persistent 16 bit interface indexes and keep one interface index match one interface name for network management After deleting a logical interface the switch retains its 16 bit interface index so the same index can be assigned to the interface at interface re c...

Page 201: ... the system software update history of the active MPU 2 In IRF mode Use the reset version update record command to clear the system software update history of the active MPU on the master Related commands display version update record Examples Clear the system software update history Sysname system view Sysname reset version update record schedule job Syntax schedule job at time1 date delay time2 ...

Page 202: ...xecutes the command If a confirmation is required while the command is running the system automatically enters Y or Yes If characters are required the system automatically enters a default character string or an empty character string when no default character string is available Follow these guidelines when you schedule a job in the non modular approach You can schedule only one job and run only ...

Page 203: ... date Reboot date in the MM DD YYYY or YYYY MM DD format The YYYY value ranges from 2000 to 2035 the MM value ranges from 1 to 12 and the DD value ranges from 1 to 31 Description Use the schedule reboot at command to schedule a device reboot to occur at a specific time and date Use the undo schedule reboot command to disable the scheduled reboot function By default the scheduled reboot function is...

Page 204: ...l 3 Manage level Parameters hh mm Device reboot delay in the hh mm format The hh value ranges from 0 to 720 and the mm value ranges from 0 to 59 When the hh value is 720 the mm value cannot be more than 0 mm Device reboot delay in minutes which ranges from 0 to 43 200 Description Use the schedule reboot delay command to schedule a device reboot to occur after a delay Use the undo schedule reboot c...

Page 205: ...he default By default the detection interval is 30 seconds Some protocols might shut down ports under specific circumstances For example MSTP shuts down a BPDU guard enabled port when the port receives a BPDU Then the switch starts the detection timer If the port is still down when the detection timer expires the switch automatically brings up the port If you change the detection interval to T1 du...

Page 206: ...by is disabled and the network ports on both MPUs can forward traffic regardless of the active standby state of the MPUs If the standby MPU has a hardware failure the network ports on it might not be able to correctly forward data In strict standby mode only the network ports on the active MPU can forward traffic When an active standby switchover occurs between the MPUs the network ports on the or...

Page 207: ...PB LSQ1MPUA LSQ1CGP24TSC LSQ1CGV24PSC or LSQ1SRPD standard Enables standard operating mode standard bridging Enables MAC extended standard operating mode standard routing Enables route extended standard operating mode chassis chassis number Specifies an IRF member switch The chassis number argument represents the IRF member ID of the switch In IRF mode Description Use the switch mode command to se...

Page 208: ...l standard ipv6 chassis chassis number slot slot number undo switch mode chassis chassis number slot slot number View System view Default level 2 System level Parameters bridging Enables MAC extension mode routing Enables route extension mode mix bridging routing Enables mixed extension mode normal Enables normal mode standard ipv6 Enables IPv6 standard mode chassis chassis number Specifies an IRF...

Page 209: ...ysname undo switch mode slot 2 switch mode optional proxy board Syntax In standalone mode switch mode optional proxy board undo switch mode optional proxy board In IRF mode switch mode optional proxy board chassis chassis number undo switch mode optional proxy board chassis chassis number View System view Default level 2 System level Parameters chassis chassis number Specifies an IRF member switch...

Page 210: ...1 to 30 characters Description Use the sysname command to change the device name Use the undo sysname demand to restore the default device name The default device name is HP A device name identifies a device in a network and works as the user view prompt at the CLI For example if the device name is Sysname the user view prompt is Sysname Examples Set the device name to S2000 Sysname system view Sy...

Page 211: ...warninglimit alarmlimit undo temperature limit slot slot number hotspot sensor number In IRF mode temperature limit chassis chassis number slot slot number hotspot sensor number lowerlimit warninglimit alarmlimit undo temperature limit chassis chassis number slot slot number hotspot sensor number View System view Default level 2 System level Parameters chassis chassis number Specifies an IRF membe...

Page 212: ... below the low temperature threshold or reaches the warning threshold the system logs the event and outputs a log message and a trap When the temperature of a sensor reaches the alarming threshold the system constantly outputs log and tap messages NOTE The warning and alarming thresholds must be higher than the low temperature threshold The alarming threshold must be higher than the warning thresh...

Page 213: ... remove an entry from the job schedule Use Table 35 when you add commands in a job Table 35 Command schedule options Command Description time timeid at time date command command Schedules a command to run at a specific time and date The time or date must be later than the current system time or date time timeid one off at time command command Schedules a command to run at a specific time on the cu...

Page 214: ...onfig Sysname job saveconfig view monitor Sysname job saveconfig time 1 one off at 8 00 month date 5 command save a cfg Schedule a job to save the configuration file a cfg at 8 00 every month Sysname system view Sysname job saveconfig Sysname job saveconfig view monitor Sysname job saveconfig time 1 repeating at 8 00 month date 5 command save a cfg Schedule a job to save the configuration file a c...

Page 215: ...um value of the delay timer is 30 days Changing a clock setting does not affect the schedule set by using the time delay command command command Command to run at a specified time Description Use the time delay command to configure a scheduled job to be executed after a delay time Use the undo time command to remove the configuration NOTE The commands in a scheduled job must be in the same view Ev...

Page 216: ...fied for a job Every job can have only one view If you specify multiple views the one specified the last takes effect Input a view name in its complete form and make sure that the view name is available on the switch Most commonly used view names include monitor for user view system for system view and Ethernetx x x GigabitEthernetx x x or Ten GigabitEthernetx x x for Ethernet interface view Examp...

Page 217: ...tabits 19 debugging 52 delete 79 delete 54 dir 54 dir 81 disconnect 55 display alarm 155 display archive configuration 103 display boot loader 123 display clipboard 3 display clock 156 display command alias 4 display cpu usage 157 display cpu usage history 160 display current configuration 104 display device 163 display device manuinfo 165 display diagnostic information 167 display environment 168...

Page 218: ...tp server acl 46 ftp server enable 47 ftp timeout 47 ftp update 48 G get 60 H header 187 history command max size 27 hotkey 7 I idle timeout 27 issu accept 140 issu commit 141 issu load 143 issu rollback 146 issu rollback timer 147 issu run switchover 148 J job 188 L lcd 61 loadsharing enable 189 lock 28 ls 61 M mkdir 62 mkdir 87 mmu monitor enable 190 modem 29 modem auto answer 30 modem timer ans...

Page 219: ...to update config 1 15 speed user interface view 36 startup saved configuration 1 16 stopbits 37 strict standby enable 199 super 9 super authentication mode 10 super password 1 1 switch mode for LPUs 201 switch mode for MPUs 199 switch mode optional proxy board 202 sysname 203 system failure 203 system view 12 T telnet 38 telnet client source 39 telnet ipv6 39 telnet server enable 40 temperature li...

Page 220: ...istering you will receive email notification of product enhancements new driver versions firmware updates and other product resources Related information Documents To find related documents browse to the Manuals page of the HP Business Support Center website http www hp com support manuals For related documentation navigate to the Networking section and select a networking category For a complete ...

Page 221: ...arated by vertical bars from which you select one choice multiple choices or none 1 n The argument or keyword and argument combination before the ampersand sign can be entered 1 to n times A line that starts with a pound sign is comments GUI conventions Convention Description Boldface Window names button names field names and menu items are in bold text For example the New User window appears clic...

Page 222: ...ng capable device such as a router or Layer 3 switch Represents a generic switch such as a Layer 2 or Layer 3 switch or a router that supports Layer 2 forwarding and other Layer 2 features Port numbering in examples The port numbers in this document are for illustration only and might be unavailable on your device ...