552
Chapter 8, Programming The Call Processing Subsystem
Programming The CALL BIT Screen
Data Spec
This field is used to determine how the contents of the signaling messages are
built.
•
Std
= Use the signaling formats defined in the applicable industry standard to build the
forward control channel and forward voice channel signaling messages. Use the
contents of the applicable fields on the CALL CONTROL screen and the CALL
CONFIGURE screen to obtain information necessary to build the messages. Whenever
a signaling message is used, update the contents of all fields in that message on the
CALL BIT screen.
•
Bits
= Use the bit patterns as set on the CALL BIT screen to build all forward control
channel and forward voice channel signaling messages. For any call processing
function (that is, setting the message stream on the active control channel, registering
the mobile station, paging the mobile station, handing off the mobile station or releasing
the mobile station) the user is responsible for setting the contents of all signaling
messages used in that function. The Call Processing Subsystem host firmware uses the
messaging protocol as defined in the applicable industry standard.
The contents of the applicable fields on the CALL CONTROL screen and the CALL
CONFIGURE screen are not updated to reflect any changes made while in the Bits mode.
There is no coupling between the Bits mode and the Test Set. For example: if a mobile sta-
tion was actively connected to the Test Set on a voice channel and the user changed the
CHAN
field on the forward voice channel mobile station control message (FVC V Mes)
and sent that message to the mobile station, the mobile station would change its voice
channel assignment. However, the Test Set will stay on the voice channel assignment
specified in the
Chan:
field on the CALL CONTROL screen. This situation will result in
a dropped call. The Bits mode should not be used to change any parameter that can be set
on any other Call Processing Subsystem screen.
The :DSPecifier command is used to control this field.
The query form of the command (that is, :DSPecifier?) can be used to determine
which method is currently being used to build the contents of the signaling
messages.
Summary of Contents for 8920B
Page 10: ...10 ...
Page 16: ...Contents 16 9 Error Messages Index 673 ...
Page 17: ...17 1 Using HP IB ...
Page 48: ...48 Chapter 1 Using HP IB Remote Local Modes ...
Page 49: ...49 2 Methods For Reading Measurement Results ...
Page 61: ...61 3 HP IB Command Guidelines ...
Page 84: ...84 Chapter 3 HP IB Command Guidelines Guidelines for Operation ...
Page 85: ...85 4 HP IB Commands ...
Page 90: ...90 Adjacent Channel Power ACP ...
Page 116: ...116 Configure I O Configure ...
Page 156: ...156 Call Processing ...
Page 185: ...185 System System SYSTem ERRor Returns integer value quoted string ...
Page 242: ...242 Common Command Descriptions ...
Page 251: ...251 5 Advanced Operations ...
Page 377: ...377 7 IBASIC Controller ...
Page 458: ...458 Chapter 7 IBASIC Controller The TESTS Subsystem ...
Page 640: ...640 Chapter 8 Programming The Call Processing Subsystem Example Programs 11280 SUBEND 11290 ...
Page 643: ...643 9 Error Messages ...
Page 672: ...672 ...
Page 682: ...Index 682 ...