background image

EL-MF877-00   

Page  1 

Template Revision B 

PSG instructions for this template are available at 

EL-MF877-01

 

Product End-of-Life Disassembly Instructions

 

Product Category: Personal Computers

 

Marketing Name / Model 
[List multiple models if applicable.] 

HP 290 G1 PCI Microtower Business PC

Purpose: 

The document is intended for use by end-of-life recyclers or treatment facilities. It provides the basic instructions 

for the disassembly of HP products to remove components and materials requiring selective treatment, as defined by EU 
directive 2002/96/EC, Waste Electrical and Electronic Equipment (WEEE). 

1.0

 

Items Requiring Selective Treatment

 

1.1 Items listed below are classified as requiring selective treatment. 
1.2 Enter the quantity of items contained within the product which require selective treatment in the right column, as 
applicable. 

Item Description 

Notes 

Quantity 
of items 
included 
in product

 

Printed Circuit Boards (PCB) or Printed Circuit 
Assemblies (PCA) 

With a surface greater than 10 sq cm 
PCA, PSU 

Batteries 

All types including standard alkaline and lithium coin 
or button style batteries   PCA 

Mercury-containing components 

For example, mercury in lamps, display backlights, 
scanner lamps, switches, batteries  

   

Liquid Crystal Displays (LCD) with a surface greater 
than 100 sq cm 

Includes background illuminated displays with gas 
discharge lamps  

   

Cathode Ray Tubes (CRT) 

Capacitors / condensers (Containing PCB/PCT) 

Electrolytic Capacitors / Condensers measuring 
greater than 2.5 cm in diameter or height 

 PSU 

External electrical cables and cords 

 AC Power Cable 

Gas Discharge Lamps 

Plastics containing Brominated Flame Retardants 
weighing > 25 grams (not including PCBs or PCAs 
already listed as a separate item above) 

 System Fan 

Components and parts containing toner and ink, 
including liquids, semi-liquids (gel/paste) and toner 

Include the cartridges, print heads, tubes, vent 
chambers, and service stations.  

   

Components and waste containing asbestos 

Components, parts and materials containing 
refractory ceramic fibers 

Summary of Contents for 290 G1 PCI Microtower Business

Page 1: ...Circuit Boards PCB or Printed Circuit Assemblies PCA With a surface greater than 10 sq cm PCA PSU 2 Batteries All types including standard alkaline and lithium coin or button style batteries PCA 1 Mercury containing components For example mercury in lamps display backlights scanner lamps switches batteries Liquid Crystal Displays LCD with a surface greater than 100 sq cm Includes background illumi...

Page 2: ...ld typically be followed to remove components and materials requiring selective treatment 1 Remove access panel Step1 2 Disconnect ODD HDD power cable and ODD HDD SATA cable from ODD Step2 Step3 3 Remove ODD HDD from chassis Step4 Step7 4 Remove all cables and heat sink from MB Step8 Step11 5 Remove the Memory CPU Battery from MB Step12 Step14 6 Remove front panel from chassis Step15 7 Remove MB f...

Page 3: ...sion B PSG instructions for this template are available at EL MF877 01 Step2 Disconnect ODD power cable and ODD SATA cable from ODD Step3 Disconnect HDD power cable and HDD SATA cable from HDD Step4 Remove the driver cage from chassis ...

Page 4: ...evision B PSG instructions for this template are available at EL MF877 01 Step5 Press the ODD s latch on ODD cage Step6 Remove the ODD from ODD cage Step7 Use T 15 screwdriver to loose the screws of HDD and remove HDD from HDD cage ...

Page 5: ...te Revision B PSG instructions for this template are available at EL MF877 01 Step8 Disconnect all cables from MB Step9 Disconnect heat sink fan cable from MB Step10 Use T 15 screwdriver to loose the screws and remove heat sink ...

Page 6: ... B PSG instructions for this template are available at EL MF877 01 Step11 Use PH1 screwdriver to loose the screws and remove the heat sink fan Step12 Remove the Memory from MB Step13 Rotate the handle and open it up to remove CPU from MB ...

Page 7: ... Revision B PSG instructions for this template are available at EL MF877 01 Step14 Remove the battery from MB Step15 Remove front panel from chassis Step16 Use T 15 screwdriver to loose the screws of MB and remove MB from chassis ...

Page 8: ... instructions for this template are available at EL MF877 01 Step17 Use PH1 screwdriver to loose the screws of system fan and remove it Step18 Use T 15 screwdriver to loose the screws of PSU Step19 Press the PSU s latch on chassis and remove it ...

Page 9: ...ions for this template are available at EL MF877 01 Step20 Use PH1 screwdriver to loose screws from PSU Step21 Open the PSU cage and use PH1 screwdriver to loose the screw of PCBA cable Step22 Use PH1 screwdriver to loose screws and remove PCB from case ...

Page 10: ...EL MF877 00 Page 10 Template Revision B PSG instructions for this template are available at EL MF877 01 Step23 Use Electric Iron remove caps from PCB ...

Reviews: