background image

EL-MF877-00                                                                                                Page  2 
Template Revision A 

 

 

  

2.0 Tools Required

List the type and size of the tools that would typically be used to disassemble the product to a point where components 
and materials requiring selective treatment can be removed. 

Tool Description 

Tool Size (if 
applicable) 

Philips Head Screw Driver 

 # 2

           

          

           

              

         

            

           

          

3.0 Product Disassembly Process

3.1 List the basic steps that should typically be followed to remove components and materials requiring selective treatment:  

1.   Remove the screws securing the bulkhead to PCA using a Philips Head screw driver (16 per for J8729A). 
2.  Remove the EMI gasket from the top (1 per) and the side (2 per) of the bulkhead. Refer to Picture 1 for more details. 
3.  Remove the screws securing the clip to heat sink using a Philips Head screw driver (14 per for J8729A). Refer to 

Picture 2 for more details 

4.  Separate the clip (7 per for J8729A) & standoff (14per for J8729A) and the heat sink. 
5.  Remove the screws securing the guide pins to the PCA using a Philips Head screw driver(1 per for J8729A. Refer to  

Picture 3 for more details. Note the picture shown below is a 16slot fabric module for illustration purposes, you should 
only see 1 guide pin for a slot fabric module.   

6.  Separate the guide pins, heat sink, clip, standoff, EMI gasket, PCA and bulkhead 
7.  
8.              
9.  

10.   
11.  
12.              
13.              
14.              
15.              

3.2 Optional Graphic.  If the disassembly process is complex, insert a graphic illustration below to identify the items 