3.
Access the product rear panel (
on page 38).
4.
Remove the power supply.
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the power supply or power supply blank
to cool before touching it.
To replace the component, reverse the removal procedure.
Removing the air baffle
CAUTION:
Do not detach the cable that connects the battery pack to the cache module. Detaching the cable
causes any unsaved data in the cache module to be lost.
CAUTION:
For proper cooling, do not operate the server without the access panel, baffles, expansion slot covers,
or blanks installed. If the server supports hot-plug components, minimize the amount of time the access
panel is open.
Procedure
1.
Power down the server (
on page 36).
2.
Remove all power:
a.
Disconnect each power cord from the power source.
b.
Disconnect each power cord from the server.
3.
Do one of the following:
• Extend the server from the rack (
Extend the server from the rack
on page 37).
• Remove the server from the rack (
Remove the server from the rack
on page 37).
4.
Remove the access panel (
on page 39).
5.
Remove the air baffle.
44