• Loose the five screws with the screwdriver. 

Untighten the nut shown as picture and 

remove the extra cable.  

• Slightly screw the nut back to the body, 

plug in the 3P-AC bus end cap and tighten 

the nut.

• Plug the upper cover back to the 3P-AC 

bus connector.

2. Installation Steps

1. Accessories

2.1 Pre-installation

All accessories above are not included by the package, will 

need to be purchased separately. Please contact our sales 

representative for the price (M8 screws will need to be 

prepared by installer-self). 

Please make sure the microinverter install under the required environment. 

(Please refer to product user manual for more details).

A )

  Plan the cable length to allow the bus cable align with 

       each PV module.

B ) 

 Install the AC bus end cap:

• Use the 3P-Bus connector unlock tool to 

unlock the connector upper cover;

ITEM

DESCRIPTION

A

3P-AC Bus End Cap, IP67

B

3P-AC Bus Connector

C

3P-AC Connector Unlock Tool

D

3P-Bus Connector Unlock Tool

E

3P-AC Sub Cap

F

M8*25 screws

G

DC Extension Cable,1m

H

B C D E

F

G

H

3P-AC Bus Cable, 12/10 AWG Optional

2.2 Installation Steps

Step 1. Fix Microinverter on the Rail

A )

  Mark the approximate center of each panel on the frame.

B )

  Fix the screw on the rail.  

*Note: 