Hoymiles HMS-2000/1800-4T Quick Installation Manual Download Page 1

Region: Global   AP040390   REV1.1        © 2020 Hoymiles Power Electronics Inc. All rights reserved.

01

2. Installation Steps

1. Accessories

Step 1. Plan and install the Microinverter

All accessories above are not included by the package, will need to be purchased separately. Please contact our sales representative for 

the price (M8 screws will need to be prepared by installer-self).

Note:

1. Install the microinverter and all DC connections under the PV module to avoiding direct sunlight, rain exposure, snow layup, UV etc. 

2. Allow a minimum of 2 cm of space around the microinverter enclosure to ensure ventilation and heat dissipation.

3. Mounting torque of the 8 mm screws: 9 N·m, do not over torque.

The order of Step 1 and Step 2 can be reversed according to your planned needs.

Item

Description

A

AC Trunk Cable, 12/10 AWG Cable

B

M8*25 screws

C

AC Trunk Connector

D

AC Trunk Port Cap

E

AC Trunk Port Disconnect Tool

F

AC Trunk End Cap

G

AC Trunk Connector Unlock Tool

- Uses the AC Trunk Connector Unlock Tool to 

unlock the connector upper cover;

1 )

  Disassemble the AC Trunk Connector and remove the cable

2 )

  Install the AC Trunk End Cap at one side of AC Trunk Cable (The end of AC Trunk Cable)

3 )

  Install AC end cable on the other side of AC Trunk Cable (connected to the distribution box)

- Loose the three screws with the screwdriver. 

Untighten the cap, and remove the cable;

*Note: 

HMS-2000/1800-4T  Quick Installation Guide

I

A

B

C

D

H

E

F

G

F

A

B

C

E

G

D

A )

  Mark the position of each microinverter on the rail, according to the PV module layout.

Step 2. Plan and build the AC Bus Cable

AC Trunk Cable is used to connect the microinverter to distribution box.

A )

  Select the appropriate AC Trunk Cable according to the spacing between microinverters. The connector spacing of 

the AC Trunk Cable should be close to spacing between microinverters to ensure that they can matched. (Hoymiles 

provides AC Trunk Cable with different AC Trunk Connector spacing)

B )

  Determine the number of microinverters in each AC branch, then plan the AC Trunk Cable with the corresponding       

number of AC Trunk Connectors.

C )

  Take the required length from the whole box AC Trunk Cable and make each AC Trunk Cable.

B )  

Fix the screw on the rail.

C )  

Hang the microinverter on the 

screws, and tighten the screws. The silver 

cover side of the microinverter should be 

facing to the panel.

- Insert the AC Trunk End cap and screw the 

cap back to port, then tighten the cap.

- Unlock the port upper cover, loose the screws 

with the screwdriver and remove the extra cable. 

(If there is no cable at this side, skip the cable 

removal)

- Plug the upper cover back to the Trunk 

connector.

4.0±0.5N·m

Mounting Torque : 9 N·m

click

Reviews: