A
B
C
D
E
F
G
01
Region: Global AP040210 REV1.2 © 2020 Hoymiles Power Electronics Inc. All rights reserved.
1. Accessories
Item
Description
AC Trunk Cable, 12/10 AWG Cable
DC Extension Cable, 1 m
M8 × 25 Screws
AC Trunk Port Disconnect Tool
AC Trunk Connector Unlock Tool
AC Trunk Port Cap
AC Trunk End Cap, IP67
- Use the AC Trunk Connector Unlock Tool to
unlock the port upper cover.
*Note: All accessories listed above are not included in the package, and need to be purchased separately. Please contact our sales representative
for pricing information. (M8 screws need to be prepared by the installer.)
2. Installation Steps
Ensure the microinverter is installed in the required environment. (Refer to product user manual for more details.)
2.1 Pre-installation
A)
Plan the cable length to make the bus cable aligned with each PV module.
B)
Install the AC Trunk End Cap:
*Note: Please install the microinverter at least 50 cm above the ground/roof for better communication with the Hoymiles DTU.
2.2 Installation Steps
Step 1. Attach Microinverter on Rail
A)
Mark the center of each panel on the frame.
B)
Fix the screw on the rail.
HM-800T Series Quick Installation Guide
C)
Hang the microinverter on the screw (as
shown in the picture), and tighten the
screw. The silver cover side of the
microinverter should be facing the panel.
- Loosen the three screws with a screwdriver.
Untighten the cap as circled below, and
remove the extra cable.
- Screw the cap back into the port, and insert
the AC Trunk End Cap.
- Plug the upper cover back to the bus
connector.
*Applicable to HM-600T/700T/800T microinverters