Hove ONE ver. 1 Manual 2021-03-01 Rev. 1.0 12 / 19
Start of manual dosing
Press the MANUAL START button.
-
The pump starts and the active fields turn
yellow.
-
The
dosed
amount of grease counts from
zero
and upwards in the “MANUAL (g)” field.
Pausing/aborting
When the MANUAL grease counter reaches
the required amount or if you want to pause
the pumping, press the MANUAL STOP button.
-
Pressing the MANUAL START button will
make the pump start and continue from
where it left off.
-
Pressing the MANUAL RESET button will
abort the current dosing and reset the
“MANUAL (g)” counter.
Empty detection
If the built-in flowmeter does not register any
grease flow for a predetermined amount of
time, either during manual or automatic
dosing, the pump stops, and the grease
counter turns red and flashes “EMPTY”
.
-
Pressing the AUTO/MANUAL START button
will start the pump again
-
Pressing the AUTO/MANUAL RESET button
will abort the dosing.