INSTALLATION LOCATION
Figure 5
Figure 6
Figure 7
Location - All Models
Select a location near the center of the space to be heated.
The heat will circulate through doorways into adjacent rooms.
Install the furnace on an outside wall. Locate wall studs so
that wall opening will be located between wall studs. One
wall stud can be used for attachment of inside wall plate. The
wall opening required as shown in Figure 4 is a minimum
diameter of 6-1/4in (158.8mm). The wall mounting plate will
cover a maximum wall opening of 7in (177.8mm) diameter.
A template is provided in furnace carton for positioning furnace
on the wall. Also, refer to Figure 4 for positioning the furnace
on wall and for locating gas line connection.
Figure 4
For large homes or spread-out floor plans, two or more
furnaces are recommended.
Do not
locate furnace where a door could block the heated
air flow.
See Figure 5.
Do not
install in a closet, alcove or small hallway where the
furnace could be isolated by closing doors to the heated
space.
See Figures 6 and 7.
Do not
block air circulation of furnace.
When location is selected, check the walls to make sure there
are no obstructions such as pipes, electric wiring, etc., which
would interfere with the installation of the furnace or vent pipe.