Process monitoring learning phase Mode 1
In the standard view:
In the first line of the zone display, the
display
PmL
- process monitoring learn-
ing phase (see chapter
Alarms, Status, Functions (page 73) al-
ternates with the display of the current
value (here: 100°C).
Wait for end of function.
In the standard view:
In the first line of the zone display, the
display of the current value (here: 100
°C) is shown.
The monitoring starts automatically following the learning phase.
The process monitoring is active and supervises the status of the zones in the hot runner.
In the first line of the zone display, the
display
Pm
- process alarm (see chapter
Messages - Alarms, Status, Functions
(page 73)) alternates with the display of
the current value (here: 100 °C), when
the tolerance limit is exceeded at activat-
ed monitoring. The alarm can be output
on an output and be used for further pro-
cessing e.g. as „Stop Machine“. The
alarm message (see chapter
es - Alarms, Status, Functions (page
73)) can be acknowledged, as soon as
the control characteristic returns to nor-
mal (error fixed), otherwise the alarm is
activated immediately again.