KABUTO
User Manual
English
Installation
Instruction
Accessories
Mounting Screws
(3 pcs.)
1. DESCRIPTION
2. DIMENSIONS
3. LED INDICATORS (Operation LED)
Disregarding this
symbol may result in
serious injury or death
Note
Special attention is required when this symbol is shown
WARNING
!
CAUTION
!
6.5m
(23.1ft)
A
B
Mounting height of
6.5m (21.3ft) or lower
Adjust the sensor body
so that the sensor does
not detect the door.
Ensure there are no
moving objects in the
detection zone
Use different frequency
settings for sensors in
close proximity
Ensure the minimum of
reflected sunlight from
the floor
4. MOUNTING PRECAUTIONS
Ensure no condensation
gets onto the sensor.
If possible ensure no
accumulation of snow or
water on the floor.
Green
Standby
Green blinking
Sensor Initializing
Red
Infrared Detecting / RADAR and Infrared Detecting
Red blinking
RADAR Detecting
Yellow
Inner detection "ROW 1" is detecting door movement
Green/Red blinking (Fast)
Internal Sensor Error
5. TECHNICAL SPECIFICATIONS
2.87 [lb.] (1.3 [kg])
Mounting Screw 3pcs.,
Installation Instruction
Remote Control "KABUTO-RC" sold separately
-20 to +60 [Deg.C],(-4 to 140 Deg.F)
Below 80%
Model Name
KABUTO
Installation Height
3.5-6.5[m] (11.5-21.3 [ft])
Weight
Accessories
Black
Operating Temperature
Operating humidity
Supply Voltage
AC/DC 12 to 24 [V] ±10% 50/60Hz
Power Consumption
AC12V-2.5 [VA] (Max)
AC24V-3.3 [VA] (Max)
DC12V-150 [mA] (Max)
DC24V-80 [mA] (Max)
Color
IP Rate
IP65
Common Specification
Specifications of Reflection Sensor
Opto Relay Non Pole
Voltage: 48 [VDC] Max.
Current : 300 [mA] Max. (Resistance load)
Output
Output1
(IR.Output)
Output2
(Radar Output)
Active Infrared Reflective
Detection Method
Output Holding Time
Presence Timer
30 [seconds], 1,2,5,10,20[minutes],1,2 [hours] or
∞
0.25 [seconds] App.
Response Time
Specifications of Redar Sensor
Detection Method
0.5 [seconds] App.
Output Holding Time
0.1 [seconds] App.
Response Time
Transmit frequency
24.15 [GHz]
Doppler method: ( moving body detection)
Notice: Specification may be changed without prior notice.
The Radar part of the
KABUTO sensor may
be negatively influenced
by metal close to or in
the detection field
Opto Relay Non Pole
Voltage: 48 [VDC] Max.
Current : 300 [mA] Max. (Resistance load)
Sensor body
6. MOUNTING & WIRING INFORMATION
②
Drill a hole to match the mounting hole
in the mounting bracket. (3.5mm
φ
)
Drilling may cause electric shock.
Be careful of hidden wires inside the door engine cover.
⑤
Wiring to the door controller.
WARNING
!
Radar sensor unit
Infrared sensor unit
Radar sensor detection
area adjustment
③
Attach the mounting bracket with the
mounting screws provided.
④
Attach the sensor body to its mounting bracket.
Route the cable around the mounting bracket.
Cable
(
Radar Output
)
Mounting Bracket
①
Remove the sensor body from its mounting
bracket.
0.5 [seconds] App.
Remote control
confirmation LED
(Blue, Yellow &
Red)
Operation LED
(
Red, Green)
Remote control
receiver
Cable
10[m] ※Directly from the sensor.
68.5mm(2.69")
14
0m
m
(
5.
51
")
(7
0m
m
(2
.76
")
)
165mm(6.49") = Standard Mounting Pitch
(82
.5m
m (3
.24
"))
10
°
10
°
230mm(9.06")
Disregarding this symbol may
result in injury or damage to
equipment
Side View
Recommended screw tightening torque :
5.2N
・
m
Sensor
’
s
Cable
Red
Black
White
Green
Yellow
Gray(+)
Blue
Brown(-)
(
IR. Output
)
AC/DC
12 to 24 [V]
±10%
Opto
Relay
Power
(
Non Pole
)
do not connect
do not connect
Opto
Relay
Output1
Output2
MP-10332
'19.12
-1-
-1-
-1-
-1-