HR400-IND
User Manual
Cover
50mm
50mm
Remove the cover from the unit.
Attach the mounting template with its bottom edge parallel to
the same position as the bottom edge of the engine cover.
English
Green
Standby.
Green blinking
Doorway Learning (When dip switch Y 8 is ON).
Red
Inner Rows Detecting.
Blue Outer Rows Detecting.
Orange
Detection row “ROW1”(“ROW2” when “Doorway
Learn” is turned ON) is detecting door movement.
Orange blinking
Indicates a change of dip switch settings or sensitivity volume.
Green/Red blinking
Internal Sensor Error.
Installation
Instruction
Accessories
Mounting Template
Cable
[8.0m (26.2ft)]
1. DESCRIPTION
3 Rows ON
2 Rows ON
4 Rows ON
5 Rows ON
Door
OFF
ON
☆
= Default Setting
Doorway
Learn
2. DIMENSIONS
3. LED INDICATORS
5. TECHNICAL SPECIFICATIONS
6. MOUNTING & WIRING INFORMATION
7. DIP SWITCH SETTINGS
Description
The sensor will detect a stationary object for the period of time of
the presence timer set.
Applies to Rows 1,2 when Doorway Learn is "OFF" and Rows 1,2,3
when Doorway Learn in "ON".
Possible Setting Options
Function
Presence
Timer
Detection
Rows
The number of rows of detection can be selected by setting to 5, 4, 3,
2 depending on detection area requirements.
Frequency
“Doorway Learn” allows the 1
st
row of detection to be focused inside
the door close area without detecting the door movement.
Dip Switch Y
Dip Switch X
Dip Switch X
R5
☆
3
4
Disregarding this
symbol may result in
serious injury or death.
Note
Special attention is required when this symbol is shown.
Drill h oles for mounting [3.5mm ( 0.14 ") φ ] and for wiring
[10mm (0.39") φ] .
Drilling may cause electric shock.
Be careful of hidden wires inside the door engine cover.
Fasten the unit with 2 mounting
screws.
Connect wire.
1
2
3 4 5 6
7 8
Note
To maximize the effectiveness of doorway detection, install the HR400-IND outside and inside as shown below.
Side View
WARNING
!
CAUTION
!
Disregarding this symbol may
result in injury or damage to
equipment.
A
B
Mounting height
is 4.7m (15.4ft)
or lower.
Mount within 50mm(1.97")
from the bottom of the door
engine cover.
Ensure there are no
moving objects in the
detection zone.
Use different frequency
settings for sensors in
close proximity.
Ensure the minimum of
reflected sunlight from
the floor.
4. MOUNTING PRECAUTIONS
Ensure no condensation
gets onto the sensor.
If possible , ensure no
accumulation of snow
or water on the floor.
If the sensor is exposed
to excessive rain install
with a Hotron weather
cover.
WARNING
!
Replace Cover.
House connectors in the receptacle.
A
B
Moving Door Leaf
Moving Door Leaf
Plan View
R4
3
4
R3
3
4
R2
3
4
2s
☆
1
2
60s
1
2
1
2
1
2
10m
∞
A
☆
5
6
B
5
6
5
6
5
6
C
D
8
8
☆
When “Doorway Learn” is turned ON, the sensitivity level
of the 1
s t
row of detection is at maximum o n l y when the
outer rows of detection are activated.
Monitor
Mode
When set to ON, pedestrians moving away from the sensor will not be
detected.
Note
☆
2s
1
2
R5
☆
3
4
A
☆
5
6
OFF
8
☆
Direction
Detection
Description
Possible Setting Options
Function
For pedestrian's safety when “Doorway Learn” is set
to ON the 1
st
and 2
nd
row of detection will detect pedestrians
regardless of direction of movement.
ON
7
7
OFF
☆
7
OFF
☆
Normal
☆
Cable {8.0[m] (26.2[ft])}, Mounting Template, Installation Instruction
-20 to +60 [Deg.C],(-4 to 140 Deg.F)
Below 80%
Model Name
HR400-IND
Active Infrared Reflection
Installation Height
Detection Method
Approx. 0.5s
Output Holding Time
Presence Timer
0.1s
Output
Weight
Accessories
Black, Silver
Operating Temperature
Operating Humidity
Response Time
Supply Voltage
AC/DC 12 to 24 [V] ±10% 50/60Hz
Power Consumption
AC12V-2.5 [VA] (Max)
AC24V-2.5 [VA] (Max)
DC12V-140 [mA] (Max)
DC24V-65 [mA] (Max)
Color
IP Rate
IP54 (With Base)
Notice: Specification may be changed without prior notice.
Dip Switch Y
Mounting Screw(2pcs.)
Potentiometer
(Sensitivity Volume)
Connector
Indicator LED
Depth Adjustment Screw
Detection
Window
Dip Switch
Width Adjustment Knob
61
mm
(2.
40
")
37.5mm
(1.47")
265mm(10.43")
178mm(7.00")
75mm(2.95")
4.7m
(15.4ft)
4.7[m] (15.4 [ft]) MAX
2s, 60s, 10m or ∞
0.64 [lb.](0.29[kg])
Connector
of the unit.
Wiring
Cable
Red & Black (Power)
White
(Common)
Yellow
(N.O.)
Green
(N.C.)
Form 1C Relay DC 50 [V], 0.1[A] Resistor Load
1 2
3 4
5 6
7 8
Set to Snow1, Snow2 or Snow3 in case false door activations occur
from blowing snow, leaves or rubbish in the door close area.
Snow1
Normal
☆
7
8
7
8
7
8
Snow2
7
8
Snow3
7
8
Detection
Rows
:
Left Side
R6
☆
1
2
Left side detection area width can be set to 6, 4 or 2 rows.
R6
☆
1
2
R4
1
2
1
2
1
2
R2
3
4
3
4
3
4
3
4
☆
5
6
5
6
5
6
5
6
2.0m(6.6ft)~
2.5m(8.2ft)
☆
☆
3
4
☆
5
6
Installation
Height
Settings
R6
Right side detection area width can be set to 6, 4 or 2 rows.
Set to installation height required.
2.5m(8.2ft)~
3.0m(9.8ft)
3.0m(9.8ft)~
3.5m(11.5ft)
3.5m(11.5ft)~
4.7m(15.4ft)
R2
Y 8
Y 8
“Doorway Learn” is ON
Ref section 7, Dip Switch Settings.
Green LED blinks for 37s (MAX.) while the “Doorway Learn”
process is carried out. Door opens/closes.
Presence Detection:
During the “Doorway Learn” process the HR400-IND switches from motion to presence
detection 10s after power ON. The inner “Doorway Learn” row of detection will switch from motion
to presence detection after the “Doorway Learn” process is completed.
Upon power ON, the Red LED
indicates a door open relay output to
begin the “Doorway Learn” process.
After the “Doorway Learn”
process is completed, sensor
is in a standby mode.
“Doorway Learn” is OFF
Ref section 7, Dip Switch Settings.
Upon power ON, the solid Green LED turns on indicating
that the sensor is in a standby mode and ready to detect.
Presence Detection:
It takes 10s after sensor
power up for presence detection to be initiated.
If before 10s has elapsed someone walks into the
detection area, all rows of detection on HR400-IND
switch from motion detection to presence detection
5s after the person leaves the detection area.
8. APPLYING POWER AND THE “DOORWAY LEARN” SETTING
When carrying out the following work, turn off sensor power.
※
When the floor condition is changed by placing a mat on the floor etc.
※
When the detection area pattern or sensor sensitivity is adjusted.
Red solid LED
Green blinking LED
Green blinking LED
Green solid LED
Green solid LED
CAUTION
!
“Doorway Learn” Failure & Recovery:
If a person enters the detection area during the “Doorway Learn” process
it may not be successfully completed. In this case the sensor will carry out the “Doorway Learn” process on door
activation caused by a person in order to create an accurate image of opening and closing of the door.
When more than two sensors are installed in close proximity to each
other select different frequency settings for each sensor to prevent
cross interference.
6 Rows ON
4 Rows ON
2 Rows ON
6 Rows ON
4 Rows ON
2 Rows ON
A
B
R6
R4
R2
R2
Door
2.0m(6.6ft)~
2.5m(8.2ft)
After setting the Installation Height, refer to
(10. VERIFICATION OF OPERATION) to set the correct
corresponding sensor sensitivity.
Note
Snow1(Weak) / Snow2(Middle) / Snow3(Strong)
Note
When “Doorway Learn” is turned ON, the sensitivity level of the inner row of detection is at maximum only
when the outer rows of detection are activated.
Note
If you change dip switch settings or sensitivity volume, the sensor will reset itself. During resetting, an orange LED will blink.
CAUTION
!
(1.97")
(1.97")
(1.97")
General Caution:
Max 50mm
Detection
Rows
:
Right Side
Note:
Inner rows refer to Rows 1,2,3 when Doorway Learn is turned "ON" and rows 1,2 when
Doorway Learn is turned "OFF".
Outer rows refer to Rows 4,5 when Doorway Learn is turned "ON" and rows 3,4,5 when
Doorway Learn is turned "OFF".