background image

 

FITTING AND OPERATING INSTRUCTIONS 

DOMINO 1100 RC 

DOMINO 1XXX, other versions

 

Radar motion sensors for the detection of objects for automatic gates. 

 

 

SAFETY INFORMATION 

The unit is only to be operated with voltages that comply with the  
Safety Extra-Low Voltage (SELV) requirements in safety 
standards based on IEC 60950. This unit is only to be installed  
and maintained by trained, qualified personnel.

 

 

 

1. FITTING 

 
1.1 

OPENING THE RADAR SENSOR UNIT   

 

 

 

1.2 DRILLING

 

 
     from the rear, prior to installation      

  

       

from the front, after installation

 

Stick the drilling template in place and drill 

  

  according to the instructions

 

 

 

 
 
 
 
 
 
 

 

1.3 

FASTENING AND CONNECTING-UP

 

 
Draw the cable through the opening provided

  

 

 

 

Connect the cable to the terminals

 

 

 
 
 
 

 
 
 

 
 

 
 

1 power supply AC/DC    brown 
2 power supply AC/DC    green 
3 Main relay  

white 

4 Main relay 

yellow 

 
   Vehicle relay 

  grey 

   Vehicle relay 

  pink

 

 
 
 
 
 
 
 
 

 

 

Fasten the base plate with the screws contained in the housing, 
to remove and insert the electronics, observe the instructions in point 2.3

 

 

 
1.4 

OTHER INSTALLATION OPTIONS

 

Optional accessory out of the 4tec accessory range. 

 
 

Ceiling-mounting with mounting bracket 

 

or  

 

Wall fastening with weather-cap set 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 

Summary of Contents for Domino 1100 RC

Page 1: ...or to installation from the front after installation Stick the drilling template in place and drill according to the instructions 1 3 FASTENING AND CONNECTING UP Draw the cable through the opening pro...

Page 2: ...L 2 1 2 IR receiver 3 IR transmitte 7 9 8 10 5 5 Terminal power supply 6 Vehicle relay 7 Terminal vehicle rela 8 Button Menu 9 Button Value 10 LED 2 3 2 3 CHOICE AND EXCHANGE OF ANTENNA 2 ettings Dete...

Page 3: ...ion w ross traffic fade out mit Richtungserkennung stereo forwards towards the radar sensor unit backwards away from the radar sensor unit forwards backwards The direction recognition can completely b...

Page 4: ...relay switches vehicle relay switches not LED fast flashing green red Gate remains closed gate opens person uses the pedestrian door main relays vehicle relays DOMINO 1100 RC GATE CONTROL UNIT Gate wi...

Page 5: ...4x red and 3x green output hold time VALUE 1 0 s push button VALUE 3x LED flashing 4x red and 6x green output hold time VALUE 3 0 s push button MENU approx 2s stop programming setting automatically s...

Page 6: ...the current setting can be read out and shown on display The required value can be selected with the arrow push buttons and confirmed and transmitted with pushing the select button The mark shows imme...

Page 7: ...ncluded self adhesive drilling template 7 TECHNICAL DATA Supply voltage 12 36 V DC 12 28 V AC Current consumption approx ca 50 mA 24 V DC 20 C Power 1 W Microwave module K band 24 05 GHz 24 25 GHz Tra...