Hotpoint RB797BBBB Manual Download Page 1

Specification Created 7/99

RB797BBBB - Hotpoint 30" Free-Standing Self-Clean Electric Convection Oven

Dimensions (in inches)

R

Listed by
Underwriters
Laboratories

All Hotpoint ranges are equipped
with an Anti-Tip device. The 
installation of this device is 
an important, required step in 
the installation of the range.

25-7/16

46-1/8

1/4

29-7/8

45-1/8

Note: 

Check local codes for required breaker size.

A properly grounded branch circuit with a 3 prong grounding type 
receptacle is required for Hotpoint ranges.

Note: 

30" Electric Ranges conform to U.L. requirements for 0" spacing

from walls below countertops. However some kitchen cabinet 
finishes can be damaged by heat from the range heating elements. It 
is recommended that a clearance of at least 1-1/2 inches be maintained
to walls. Where varnished wood or plastic film finishes are used, a 
minimum clearance of 6 inches should be maintained.

Receptacle Locations: 

Locally approved flexible service cord or conduit

must be used because terminals are not accessible after range
installation. See shaded area in drawing for location of electrical outlet
box. Recommended outlet locations allow range to be installed directly
against rear wall.

Installation Information:

Before installing, consult installation 

instructions packed with product for current dimensional data. 

CENTER LINE

2-1/4

7-1/2

7-1/2

7

5

2-1/4

3-1/2

REAR
WALL

The range may be placed with

0" clearance (flush) at the back
wall and side walls if the range
side trims extend beyond the
cabinet fronts at least 1/4".
Self-Clean models only

KW Rating

240V

10.6

208V

8.0

Breaker Size

40 Amps

Reviews: