background image

HTDP120GD – Hotpoint

®

 6.8 cu. ft. capacity DuraDrum

 gas dryer

Dryer Dimensions (in inches)

Specification Created 1/12

470163

Exhaust Options: 

3-way via rear, left and bottom. Dryer is shipped exhausted to the rear. Alternate exhausting 

knockouts are supplied. 

Circuit Requirements: 

An individual properly-grounded branch circuit, with a three-prong grounding-type receptacle, 

protected by a 15- or 20-amp circuit breaker or a time-delay fuse is required.

Gas Dryer Electric Rating:  

120V, 60Hz, 6 Amp

Gas (BTU/HR): 

22,000. Factory-equipped for natural gas. Tested for LP gas. LP gas supply 

requires an optional conversion kit. Check installation instructions for  correct kit and have a 

qualified gas technician install a conversion kit. See dryer ducting information for proper 

installation.

Installation Information: 

For complete information, see installation  

instructions packed with product for current dimensional data.

Special Installation Requirements
Alcove or Closet Installation: 

•  If your dryer is approved for installation in an alcove or closet, it will be stated on a 

label on the dryer back.

• The dryer MUST be exhausted to the outside.

•  Minimum clearances between dryer cabinet and adjacent walls or other surfaces are: 

       0" either side 

       3" front and rear

• Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52". 

•  Closet doors must be louvered or otherwise ventilated and must contain a minimum of 

60 sq. in. of open area equally distributed. If this closet contains both a washer and a 

dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.

• No other fuel-burning appliance shall be installed in the same closet with a gas dryer.

Bathroom or Bedroom Installation:

• The dryer MUST be exhausted to the outdoors. 

•  The installation must conform with the local codes, or in the absence of local codes, 

with the National Electric Code and National Fuel Gas Code, ANSI Z223 for gas dryers.

Minimum Clearances other than Alcove or Closet Installation:

•  Minimum clearances to combustible surfaces 

       0" both sides 

       3" rear

36

24

42-3/4

51

Side View

24

Rear View

36

42

27

2

5-1/2

2-1/2

25-1/2*

Side View

Rear View

4-3/4

25-3/4

23-1/2

11-3/4

HTPWasher/Dryess LC QSart

* 24-1/2” from the edge of the side panel to the front.  

25-1/2” from front to edge of end caps.

Reviews: