38
C. Settings and Adjustments
NOTICE
Dip switches are factory set. Failure to maintain factory settings may adversely
affect performance and warranty coverage. For more information, contact Hoshizaki
Technical Support at 1-800-233-1940.
1. Default Dip Switch Settings
The dip switches are factory-adjusted to the following positions:
S4 Dip Switch
Dip Switch No.
1
2
3
4
5
6
7
8
9
10
KMS-1122MLJ OFF OFF OFF OFF ON OFF ON OFF OFF OFF
S5 Dip Switch (Do Not Adjust)
Dip Switch No.
1
2
3
4
5
KMS-1122MLJ
OFF OFF OFF OFF ON
Freeze Timer (9 & 10)
Pump-Out Frequency Control (5)
Pump-Out Time/Harvest Time During Pump-Out (3 & 4)
Harvest Timer (1 & 2)
Factory Use (8)
Harvest Pump Time (Harvest Assist)/Freeze-Time Correction (7)
(Do Not Adjust)
1
2
3
4
5
6
7
8
9
10
ON
S4 Dip Switch
"J" Control Boards
Harvest Pump Time (Harvest Assist Duration) (6) (Do Not Adjust)
1
2
3
4
5
ON
Do Not Adjust
S5 Dip Switch
"J" Control Board Only
Refill Counter (2 and 3)
Float Switch Selector (1)
Minimum Harvest Time (4)
Anti-Slush (5)