![Hoshizaki KMD-901MAH Service Manual Download Page 7](http://html1.mh-extra.com/html/hoshizaki/kmd-901mah/kmd-901mah_service-manual_2164793007.webp)
7
3. KMD-901MRH (remote air-cooled)
Note: We reserve the right to make changes in specifications and design without prior
notice.
AC SUPPLY VOLTAGE
208-230/60/1 (3 wire with netrual for 115V)
AMPERAGE
10.0A ( 5 Min. Freeze AT 104°F / WT 80°F)
MINIMUM CIRCUIT AMPACITY
20 A
MAXIMUM FUSE SIZE
20 A
APPROXIMATE ICE PRODUCTION
Ambient
WATER TEMP. (°F)
PER 24 HR.
Temp.(°F)
50
70
90
lbs./day ( kg/day )
70
*848 (385)
827 (375)
768 (348)
Reference without *marks
80
832 (377)
798 (362)
723 (328)
90
827 (375)
*775 (352)
705 (320)
100
805 (365)
759 (344)
641 (291)
SHAPE OF ICE
Crescent Cube
ICE PRODUCTION PER CYCLE
12 lbs. (5.4 kg) 624pcs.
APPROXIMATE STORAGE CAPACITY
N/A
ELECTRIC & WATER CONSUMPTION
90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
1710(5.3)
1600(4.5)
WATER gal./24HR (gal./100 lbs.)
155(20.0)
383(45.2)
EXTERIOR DIMENSIONS (WxDxH)
30" x 24-5/8" x 28" (762 x 625 x 713 mm)
EXTERIOR FINISH
Stainless Steel, Galvanized Steel (Rear)
WEIGHT
Net 226 lbs. (103 kg), Shipping 258 lbs. (117 kg)
CONNECTIONS - ELECTRIC
Permanent - Connection
- WATER SUPPLY
Inlet
1/2" FPT
- DRAIN
Outlet
3/4" FPT
5/8" OD Tube
CUBE CONTROL SYSTEM
Float Switch
HARVESTING CONTROL SYSTEM
Hot Gas and Water, Thermistor and Timer
ICE MAKING WATER CONTROL
Timer Controlled. Overflow Pipe
COOLING WATER CONTROL
N/A
BIN CONTROL SYSTEM
Mechanical Lever Switch and Timer
COMPRESSOR
Hermetic, Model CS10K6E-PFV-279
CONDENSER
Air-Cooled Remote, Condenser Unit URC-9F
EVAPORATOR
Vertical type, Stainless Steel and Copper
REFRIGERANT CONTROL
Thermostatic Expansion Valve
Condensing Pressure Regulator on URC-9F
REFRIGERANT CHARGE
R404A, 9 lbs. 14.7 oz. (4500g)
(Icemaker 5 lbs. 15.9 oz. Cond. Unit 3 lbs. 14.8 oz.)
DESIGN PRESSURE
High 467PSIG, Low 230PSIG
P.C. BOARD CIRCUIT PROTECTION
High Voltage Cut-out ( Internal )
COMPRESSOR PROTECTION
Auto-reset Overload Protector ( Internal )
REFRIGERANT CIRCUIT PROTECTION
Auto-reset High Pressure Control Switch
LOW WATER PROTECTION
Float Switch
ACCESSORIES -SUPPLIED
N/A
-REQUIRED
Ice Dispenser or Ice Storage Bin, Remote Condenser Unit
OPERATING CONDITIONS
VOLTAGE RANGE
187 - 253 V
AMBIENT TEMP.
45 -100° F
WATER SUPPLY TEMP.
45 - 90° F
WATER SUPPLY PRESSURE
10 - 113 PSIG