![Hoshizaki KMD-901MAH Service Manual Download Page 30](http://html1.mh-extra.com/html/hoshizaki/kmd-901mah/kmd-901mah_service-manual_2164793030.webp)
30
C. Performance Data
1. KMD-901MAH (air-cooled)
Note:
1. Pressure data is recorded at 5 minutes into freezing cycle. The data not in
bold
should be used for reference only.
2. We reserve the right to make changes in specifications and design without prior
notice.
70/21
890
404
864
392
803
364
80/27
870
395
830
376
754
342
90/32
864
392
801
363
730
331
lbs./day kg./day
100/38
843
382
784
356
665
302
70/21
80/27
90/32
watts
100/38
70/21
372
1.41
310
1.17
280
1.06
80/27
325
1.23
228
0.86
230
0.87
90/32
310
1.17
160
0.61
148
0.56
gal./day m
3
/day
100/38
240
0.91
157
0.60
136
0.52
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
231
16.2
251
17.6
281
19.8
80/27
246
17.3
276
19.4
309
21.7
90/32
251
17.6
298
21.0
330
23.2
PSIG kg/cm
2
G
100/38
258
18.1
306
21.5
360
25.3
70/21
36
2.5
39
2.7
45
3.2
80/27
38
2.7
43
3.0
51
3.6
90/32
39
2.7
46
3.2
53
3.7
PSIG kg/cm
2
G
100/38
41
2.9
48
3.4
60
4.2
16,300 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
16
19
17
17
19
17
18
2.0
3.3
2.5
3.0
2.4
2.0
3.0
16
APPROXIMATE ICE
PRODUCTION PER 24 HR.
APPROXIMATE ELECTRIC
CONSUMPTION
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
WATER TEMP. (ºF/ºC)
AMBIENT TEMP.
(ºF/ºC)
50/10
70/21
90/32
1845
1848
1898
1940
1945
1810
1839
1848
18
20
21
23
1876
1913
1961
1980
HARVEST CYCLE TIME
HEAD PRESSURE
2.8
2.5
3.0
2.0
2.0
TOTAL HEAT OF REJECTION FROM CONDENSER
SUCTION PRESSURE