VI. Preparing the Appliance for Periods of Non-Use
NOTICE
• When storing the appliance for an extended time or in sub-freezing temperatures,
follow the instructions below to prevent damage.
• To prevent damage to the water pump, do not operate the appliance with the
control switch in the "SERVICE" position when the water tank is empty.
When the appliance is not used for two or three days under normal conditions, it is
sufficient to move the control switch to the "OFF" position. When storing the appliance for
an extended time or in sub-freezing temperatures, follow the instructions below.
1. Remove the water from the icemaker water line:
1) Remove the louver, then move the control switch to the "OFF" position. Wait 3 min.
2) Close the icemaker water supply line shut-off valve and open the icemaker water supply
line drain valve.
3) Allow the line to drain by gravity.
4) Attach a compressed air or carbon dioxide supply to the icemaker water supply line
drain valve.
5) Make sure at least 3 min. have elapsed. Move the control switch to the "ICE" position.
6) Blow the icemaker water supply line out using the compressed air or carbon dioxide
supply.
7) Close the icemaker water supply line drain valve.
2. Remove the water from the water tank:
1) Move the service switch to the "DRAIN" position, then move the control switch to the
"SERVICE" position. Allow the water tank to drain completely.
2) After all of the water has drained, move the control switch to the "OFF" position, then
unplug the icemaker from the electrical outlet.
3) Remove all ice from the ice storage bin. Clean the storage bin liner using a neutral
cleaner. Rinse thoroughly after cleaning.
3. On water-cooled model, remove the water from the water-cooled condenser:
1) Make sure the appliance is unplugged and the control switch is in the "OFF" position.
2) Close the condenser water supply line shut-off valve. If connected to a closed loop
system, also close the condenser return line shut-off valve.
3) Open the condenser water supply line drain valve. If connected to a closed loop system,
also open the condenser return line drain valve.
4) Attach a compressed air or carbon dioxide supply to the condenser water supply line
drain valve.