7
3. F-1001M_J(-C)
Single Phase
Model Number
F-1001MAJ(-C)
F-1001MWJ(-C)
F-1001MRJ(-C)
F-1001MLJ(-C)
AC Supply Voltage
115/60/1
115/60/1
115/60/1
115/60/1
Compressor
115V 12RLA 93LRA 115V 12RLA 93LRA 115V 11.2RLA 93LRA --- --- ---
Gear Motor
115V 3.0FLA 200W 115V 3.0FLA 200W 115V 3.0FLA 200W
115V 3.0FLA 200W
Fan Motor
115V 1.0FLA 1/15HP --- --- ---
REMOTE 115V 1.0FLA
1/12HP
--- --- ---
Other
120V 0.03A
120V 0.03A
120V 0.53A
120V 0.53A
Maximum Fuse Size 20 AMPS
20 AMPS
20 AMPS
15 AMPS
Max. HACR Breaker
(USA Only)
20 AMPS
20 AMPS
20 AMPS
15 AMPS
Max. Circuit Breaker
(Canada Only)
20 AMPS
20 AMPS
20 AMPS
15 AMPS
Minimum Circuit
Ampacity
20 AMPS
20 AMPS
20 AMPS
15 AMPS
Design Pressure
HI - 427PSI
LO - 230PSI
HI - 427PSI
LO - 230PSI
HI - 427PSI
LO - 230PSI
HI - 427PSI
LO - 230PSI
Refrigerant
404A 2 LB. 4.1 OZ.
404A 12.3 OZ.
404A
Total Refrigerant
Charge with Hoshizaki
Remote Condenser
Unit URC-5F:
4 LB. 1.2 OZ.
404A