109
8.6.4 Emptying the solution tank
via the pressure outlet
c
d
2
1
Pressure outlet with ball valve (d)
Position (1): closed
Position (2): open
1. Connect a drain hose with 2" Camlock cou-
pling (c) to the male part of the pressure line.
2. Open the ball valve (2).
3. Set the suction side to solution tank.
4.
Switch to the pressure side. Switch off boom
circulation, injector, agitator and inside
cleaning.
5.
Close the quick filling valve.
6. Switch on the pump and set the pressure
manually to maximum.
8.7 Hand wash - fresh water
tank
Only fill clean water into the fresh
water tank (10).
10
(10)
Hand wash - fresh water tank
Capacity: 15 l
11
(11)
Drain valve for clear water
- to clean your hands or
- to clean the spraying nozzles
WARNING
Danger of poisoning by contami-
nated water in the fresh water tank!
Never use the water in the hand washing tank
as drinking water!
The materials of the hand washing tank are not
food compatible.