© 2003 Directed Electronics, Inc. Vista, CA
13
H1/2 WHITE (-/+) SELECTABLE LIGHT FLASH OUTPUT
As shipped, with the light flash polarity jumper inside the unit in its default position (see the
Internal
Programming Jumpers
section of this guide), this wire supplies a (-) 200 mA output, which is suitable for driving
a negative (-) parking light relay.
If the light flash polarity jumper inside the unit is moved to the opposite positive (+) position (see the
Internal
Programming Jumpers
section of this guide), this wire supplies a (+) 200 mA output, which is suitable for driving
(+) parking light wires.
H1/3 WHITE/BLUE (+) TRUNK RELEASE, SENSOR SHUNT INPUT
This input is used to bypass sensor inputs when the trunk is opened using the factory transmitter. Connect this
wire to the (+) trunk release output of the factory keyless entry system or trunk release relay. When the system
receives a (+) input on this wire, Zones 2 and 4 are bypassed for three seconds. If ground is applied to the H1/6
BLUE wire during that three-second period, Zones 2 and 4 will remain bypassed until the ground input is removed.
This means that when the trunk is opened with the factory transmitter, the only triggers that remain active while
the trunk is open are the doors. Five seconds after the trunk is closed, the bypassed zones will become active again.
NOTE:
This connection is not required with most Class II databus systems.
H1/4 BROWN/BLACK (-) 200 mA HORN HONK OUTPUT
This wire supplies a (-) 200 mA output that can be used to honk the vehicle’s horn. It provides a pulsed output
when the security system is in the triggered sequence or in Panic Mode. In most vehicles with (-) horn circuits,
this wire can control the vehicle’s horn without adding a relay. If the vehicle has a (+) horn circuit, an optional
relay must be used to interface with the horn circuit.