XLW PRIME QUICK REFERENCE GUIDE

page 1 of 4

XLW Prime Overview

General Specifications

Primary Power Port Pins

PIN

SIGNAL

DESCRIPTION

1

Ground

Frame Ground

2

DC-

Input Power Supply Ground

3

DC+

Input Power Supply Voltage

DC Input / Frame
Solid/Stranded Wire:

 12-24 awg (2.5-0.2mm). 

Strip length

: 0.28” (7mm).

Torque, Terminal Hold-Down Screws

:  4.5 – 7 in-lbs (0.50 – 0.78 N-m).

DC- is internally connected to I/O V-, but is isolated from CAN V-.
A Class 2 power supply must be used.

POWER UP

1. OPTION: Attach ferrite core with a minimum of 
two turns of the DC+ and DC- signals from the DC 
supply that is powering the controllers. 
2. Connect to earth ground. 
3. Apply recommended power. 

Power Wiring

Required Power 
(Inrush) 

25A for 

< 1

ms @ 24VDC, DC switched

Primary Power Range

10 - 30VDC

Relative Humidity

5 to 95% non-condensing

Clock Accuracy

 + / - 20 ppm maximum at 25°C  
(+/- 1 min/month)

Real Time Clock

Battery Backed, Lithium Coin

Operating Air Temp

-10°C to +60°C 

Storage Temp

-20°C to +60°C

Weight

3.9375 lbs (1786g)

Altitude

Up to 2000m

Rated Pollution Degree

Evaluated for Pollution Degree 2 Rating

Certifications  
(UL/CE)

North America

 

Europe

XLW

Prime

NOTE:

 See Precaution #12 on page 4 about USB and grounding. 

1

Built-in I/O

  

2

3

4

5

8

7

6

10

9

1. Touchscreen
2.  USB 2.0 “A”: Flash Drive
3.  LAN Port
4.  PWR: 10-30VDC In
5.  CAN Port

6.   MJ3: RS-232/485
7.    Dip Switches
8.  MJ1/MJ2: RJ45 Serial Port
9.    microSD: Data Storage
10.  USB mini “B”: Programming

Summary of Contents for XLW PRIME

Page 1: ...s 2 power supply must be used POWER UP 1 OPTION Attach ferrite core with a minimum of two turns of the DC and DC signals from the DC supply that is powering the controllers 2 Connect to earth ground 3 Apply recommended power Power Wiring Required Power Inrush 25A for 1ms 24VDC DC switched Primary Power Range 10 30VDC Relative Humidity 5 to 95 non condensing Clock Accuracy 20 ppm maximum at 25 C 1 ...

Page 2: ...4 Digital In 4 I5 I5 Digital In 5 I6 I6 Digital In 6 I7 I7 Digital In 7 I8 I8 Digital In 8 H1 I9 HSC1 Dig In 9 H2 I10 HSC2 Dig In 10 H3 I11 HSC3 Dig In 11 H4 I12 HSC4 Dig In 12 A1 AI1 Analog In 1 A2 AI2 Analog In 2 0V Common J2 Black Name 0V Common V V NC No Connect Q12 Q12 Digital Out 12 Q11 Q11 Digital Out 11 Q10 Q10 Digital Out 10 Q9 Q9 Digital Out 9 Q8 Q8 Digital Out 8 Q7 Q7 Digital Out 7 Q6 Q...

Page 3: ...ig Out2 PWM2 Q1 Q1 Dig Out1 PWM1 OV V NC Q12 Q11 Q10 Q9 Q8 Q7 Q6 Q5 Q4 Q3 Q2 Q1 LOAD LOAD LOAD LOAD LOAD LOAD LOAD LOAD LOAD LOAD LOAD LOAD 10 30VDC J1 Orange Green Name J1A I1 I1 IN1 I2 I2 IN2 I3 I3 IN3 I4 I4 IN4 I5 I5 IN5 I6 I6 IN6 I7 I7 IN7 I8 I8 IN8 H1 I9 HSC1 V Dig In 9 H2 I10 HSC2 V Dig In 10 H3 I11 HSC3 V Dig In 11 H4 I12 HSC4 V Dig In 12 J1B 0V Common A1A AI33 Univ AI 1 Pin 1 A1B AI33 Univ...

Page 4: ...ECOMPOSANTS PEUT RENDRECE MATE RIEL INACCEPTABLE POUR LES EMPLACEMENTS DE CLASSE I DIVISION 2 3 WARNING EXPLOSION HAZARD DO NOT DISCONNECT EQUIPMENT UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE NON HAZARDOUS AND FREE OF IGNITABLE CONCENTRATIONS ATTENTION RISQUE D EXPLOSION NE DECONNECTEZ PAS L EQUIPEMENT A MOINS DE L AVOIR MIS HORS TENSION OU QUE LA ZONE EST CONNUE NON DANGEUREUSE...

Reviews: