Chapter
7
Commissioning a New System
New System Start-up Procedures
1. Ensure that the installation has been properly performed.
2. Ensure that the tube-shipping plug has been removed from the potable water outlet port of the
Water Control Manifold (Compact System) or from the RO Membrane/Vessel Product Water Port
(Modular System) and that all 1/4-inch and 3/8-inch product water tubes are connected.
3. Check the RO Membrane Element as described below.
Note: Some systems are shipped WITHOUT the RO Membrane Element. This is to
accommodate, for example, boat builders who install the system well in advance of
commissioning the boat and the Horizon Reverse Osmosis System.
If the RO Membrane Element has been installed, there will be an Element Serial Number tag
attached to the RO Membrane/Vessel Assembly. Find this serial number tag to ensure that the RO
Membrane Element has been installed.
If the RO Membrane Element Serial Number tag is missing or does not contain a serial number
and date, then immediately contact the company that sold the system to you or Horizon Reverse
Osmosis. Provide Horizon Reverse Osmosis with the system serial number and model number of
this Seafari Escape System.
Caution: DO NOT attempt to operate the system without a RO Membrane Element installed
in the system, as extensive damage will result.
4. Ensure that the manual bypass lever located on the side of the 3-Way Product Water Solenoid
Diversion Valve is positioned outward (away from the coil body).
5. Check each hose and tube connection to the system to ensure that the installer has properly
connected and routed each hose and tube. Ensure that there are no kinks or blockages in any of
the hoses or tubes leading to and from the Seafari Escape System. Improper routing and any
blockage in any line causes damage to the system. Do not rely on the installer’s word; check it
yourself.
6. Make sure that the electrical power source, the boat’s circuit breaker, to the system is switched
"OFF."
7. Open the front panel of the Main Power Enclosure. Check all electrical and electronic connections
for proper wiring and attachment.
8. Ensure that the installer has used the proper-sized power wire and Booster Pump wire.
9. Close the Main Power Enclosure front panel.
10. Open the Sea Cock Valve.
43
Summary of Contents for Seafari Escape 200
Page 2: ......
Page 6: ......
Page 10: ......
Page 28: ......
Page 73: ...3 8 1 9 2 7 5 4 3 6 Seafari Escape 200 600 74...
Page 75: ...2 5 7 6 3 4 8 1 6 4 8 3 Seafari Escape 200 600 76...
Page 77: ...8 4 1 5 3 7 3 2 6 9 4 10 11 Seafari Escape 200 600 78...
Page 89: ...7 8 6 4 1 3 1 2 4 9 5 Seafari Escape 200 600 90...
Page 91: ...9 3 6 7 8 10 4 1 1 4 5 5 2 Seafari Escape 200 600 92...
Page 93: ...13 3 10 11 14 12 8 4 6 7 9 5 1 7 9 2 Seafari Escape 200 600 94...
Page 95: ...10 18 9 6 15 5 8 16 17 7 14 3 1 20 2 4 11 13 Seafari Escape 200 600 96...
Page 103: ...5 6 2 3 2 6 7 9 9 8 1 10 5 Seafari Escape 200 600 104...
Page 113: ...12 8 9 2 10 13 1 3 5 4 14 11 6 15 7 Seafari Escape 200 600 114...
Page 116: ...1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 20 19 17 18 117 Exploded Parts View...
Page 122: ......
Page 123: ......
Page 124: ......
Page 125: ......
Page 126: ......