16
CHAPTER 5:TROUBLESHOOTING
5.5 RESISTANCE ISSUE
B)
If the ECB motor/tension control can move,
the resistance can be adjusted. If the resistance is
still too heavy, check the gap between orange block and the bottom. It should be within 1-2 mm.
If the gap is larger than 1-2 mm, the resistance will be heavier than normal. Adjust the cable to the correct
gap range.
3. If all above conditions are OK, and the resistance is still too heavy, inside magnet is defective. Replace
the ECB controller (056539-AX).