pH detector for pure water measurement
HP-8A

Instruction Manual

CODE:GZ0000406259A

Summary of Contents for HP-8A

Page 1: ...pH detector for pure water measurement HP 8A Instruction Manual CODE GZ0000406259A...

Page 2: ...he following cases none of the warranties set forth herein shall be extended Any malfunction or damage attributable to improper operation Any malfunction attributable to repair or modification by any...

Page 3: ...esult in death or serious injury This is to be limited to the most extreme situations This indicates a potentially hazardous situation which if not avoided could result in death or serious injury This...

Page 4: ...to prevent injury and damage The terms of DANGER WARNING and CAUTION indicate the degree of imminency and hazardous situation Read the precautions carefully as it contains important safety messages W...

Page 5: ...ation of the cable is weakened Use this product in an environment free from corrosive gas Avoid using this product in a location close to equipment using strong electric power such as an electric furn...

Page 6: ...s manual Note This interprets the necessary points for correct operation and notifies the important points for handling the product Reference This indicates the part where to refer for information Tip...

Page 7: ...w cell 2 Installation 3 Mounting of pH detector for pure water measurement 3 Installation on a pole 3 Installation on a wall 3 Wiring 4 Attaching a pH electrode 5 Piping 6 Selector valve operation 7 M...

Page 8: ......

Page 9: ...pH meters Refer to the instruction manuals for the key operation or setting of each transmitter Unpacking Upon delivery of this product unpack the packing immediately and check the contents of the pac...

Page 10: ...flow cell KCl tank Case Funnel Sample outlet Temperature sensor 6 8 k pH flow cell Funnel cover Hose Tank bracket Sample inlet pH electrode Selector valve knob O ring P6 O ring P8 O ring P6 O ring P45...

Page 11: ...ture sensor cable L 6 m 60 5 50 A pole 40 41 5 113 167 202 15 6 24 58 93 296 236 35 83 70 size is approximate Unit mm 4 10 pH electrode cable L 6 m 20 360 557 330 93 25 202 557 330 35 20 360 4 10 83 7...

Page 12: ...ectrode terminal T T Temperature compensation terminals E Shield wire G R T Temperature sensor pH electrode EL 6121 Ground resistance of 100 or less Load resistance 600 24 V DC pH detector for pure wa...

Page 13: ...p nut E and lead the pH electrode cable through the cap nut E 7 Lead the pH electrode into the electrode holder and fasten the cap nut E 8 Screw the skirt HP to fasten the liquid junction 9 Insert the...

Page 14: ...h a suitable joint 2 There is Rc1 4 screw on the sample outlet For the plumbing attach a suitable joint The plumbing should be atmosphere opening which the tip does not rise KCl tank 1 Fill the KCl ta...

Page 15: ...n Image MEAS Sample comes to the cell and overflows for measuring pH of sample at MEAS position DRAIN DRAIN position drains all the liquid out of the cell CAL CAL position shuts the sample line and le...

Page 16: ...e 7 2 Perform measurement referring to the instruction manual of the transmitter Note The consumption of the KCl solution is 400 mL from 200 mL in one month Replenish the KCl solution every 2 weeks or...

Page 17: ...re water washing 1 Switch the valve from MEAS to DRAIN position to drain sample 2 Turn the valve to CAL position and pour pure water into the funnel to clean up the cell 3 Switch the valve from CAL to...

Page 18: ...4 standard solution 3 Pour the pH9 standard solution or the pH4 standard solution into the funnel and turn the valve to CAL position and wait a few minute for calibration 4 Make calibration with the p...

Page 19: ...wiring to the transmitter disconnected YES YES NO Keep the sample temperature within the mea suring condition NO Drift of reading Contact us YES NO Confirm the electrode wirings to the transmitter and...

Page 20: ...condition Temperature 0 C to 50 C Pressure 0 MPa to 0 05 MPa Sample outlet should be open to atmospheric pressure Flow rate 50 mL min to 250 mL min Conductivity 0 1 S cm or more Model Specification P...

Page 21: ...materials pH detector for pure water measurement No Part name Material No Part name Material 1 KCl tank PC 9 Funnel cover PVC 2 Sample outlet SUS316 10 Funnel PE 3 Drain PVC 11 Open air PP 4 Case SUS...

Page 22: ...d junction 23 Spacer PTFE 8 Skirt HP PVC 24 Cock holder PVC 9 Temperature sensor 25 Ball SUS304 10 Hose joint SUS316 26 Spring SUS304 11 O ring P8 CR 27 Clamping screw SUS304 12 Hose joint PVC 28 O ri...

Page 23: ...yanohigashi Kisshoin Minami ku Kyoto 601 8510 Japan http www horiba com Headquarters 31 Miyanonishi cho Kisshoin Minami ku Kyoto 601 8306 Japan TEL 81 75 321 7184 FAX 81 75 321 7291 http www horiba ad...