6844RC
-
F
UNCTIONALITY
System 6844(RC) - V03.00
129 / 157
hopf
Elektronik GmbH
Nottebohmstr. 41
• D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
7.1.1 RC-Pulses IMP 1-4 - Operating
In this setting the internal operating status is emitted at IMP 1-4.
The signal output can be inverted.
Imp 1-4
Operating
active
System 6844RC is ready
inactive
System 6844RC is not ready
7.1.2 RC-Pulses IMP 1-4 - Time Status
In this setting the internal synchronisation status is emitted at IMP 1-4.
The signal output can be inverted.
Imp 1-4
Sync.-Status
active
radio synchronous (R, r)
inactive
not radio synchronous (C, -)
7.1.3 RC-Pulses IMP 1-4 - Cyclical Pulse
In this mode cyclical pulses with adjustable pulse width are generated at IMP 1-4. Following
pulse intervals are possible::
every 1, 2, 3, 4, 6, 8, 12, 24 hours
every 1, 2, 3, 4, 5, 6 , 10, 12, 15, 20, 30 minutes
every 1, 2, 3, 4, 5, 6 , 10, 12, 15, 20, 30 seconds
The pulse length can be selected in the range
1 - 65,500 msec
. The pulse duration should
not exceed the cycle time, otherwise the output is switched through permanently.