Summary of Contents for HIS-ML15 Series

Page 1: ...15 PANEL MOUNT INDUSTRIAL MONITOR USER MANUAL Model No HIS ML15 _ _ _ H REVISION H...

Page 2: ...tep 2 Bench test Configuration 8 Install Cable Connections 8 Install Touch Screen Driver 10 Step 3 Install into Panel 12 Video Settings 14 Setting the Timing Mode 14 Control Panel Buttons 15 On Screen...

Page 3: ...installed near the equipment and shall be easily accessible DC Supplied Units only The HISML15 subject unit is to be powered by a Listed Power Supply suitable for the application with outputs at SELV...

Page 4: ...in Class I Division 2 Groups A B C and D Class II Division 2 Groups F and G Class III or non hazardous locations only Device is open type and is to be installed in an enclosure suitable for the envir...

Page 5: ...Front and Side Views Bottom View 7 1 mm 0 28 291 1 mm 11 46 353 6 mm 13 92 307 6 mm 12 11 437 8 mm 17 24 231 6 mm 9 12 348 0 mm 13 70 437 8 mm 17 24 7 1 mm 0 28 53 3 mm 2 10 Design to maximum depth of...

Page 6: ...Mechanical Drawings 6 ML15H User Manual 99141B September 2021 Rear View MENU SEL 100 mm VESA Mounting Pattern M4 screws provided 16 mm maximum depth of screw...

Page 7: ...C 122 F f Remember that heat rises the temperature at the top of the cabinet will be much hotter than at the bottom if air inside the enclosure is not actively circulating Even in a sealed enclosure...

Page 8: ...m issues while configuration changes may still be easily made Install Cable Connections All monitors are shipped with a standard VGA video cable AC powered displays are also shipped with a power mains...

Page 9: ...yPort connection this can be converted for use with the DVI video port using a simple adapter If the video source has a 5 wire analog RGB video output this can be converted for use with the VGA video...

Page 10: ...ope Industrial Systems if you require a CD ROM with documentation and drivers for touch screens For a full list of downloadable drivers please check the following Internet address https www HopeIndust...

Page 11: ...locks on the cable connectors to ensure adequate strain relief HAZ LOC NOTE If this step is not performed the product will not comply with Class I II III Division 2 Hazardous Location requirements 2...

Page 12: ...the panel Allow extra space 12 7 mm 0 5 behind and on each side for air ventilation Step 3 Install into Panel Once you have completed the full bench test configuration and confirmed that all component...

Page 13: ...elow 7 Insert the unit into the front of the panel and re attach the collar NOTE Contact Hope Industrial Systems if for any reason your application does not allow for installation of the collar 8 Tigh...

Page 14: ...setting the timing mode use the On Screen Display OSD controls to adjust the screen image TIP For the best picture quality set your computer graphics adapter timing mode to VESA 1024 x 768 60 Hz Pleas...

Page 15: ...tically after 60 seconds This is adjustable through the OSD Time out setting in the Setup menu 2 To navigate through the main OSD menu press the left or right button 3 To select a control to adjust pr...

Page 16: ...tment When the OSD menu IS displayed Navigates left in the main OSD menu Decreases adjustments for the selected control Right Up Input Source When the OSD menu IS NOT displayed Shortcut to select inpu...

Page 17: ...e Inputs OSD Info Reset to factory defaults Source scan and Advanced Setup functions Picture Menu The Picture menu includes the Contrast Brightness Sharpness and Color functions Picture Menu Descripti...

Page 18: ...tent white red blue green Please contact our support team for further details NOTE The Auto color function is only available when using the analog VGA connector Theme mode Allows the user to select fr...

Page 19: ...the screen for warmer white and richer red Normal is the factory default setting Cold adds blue to the screen image for cooler white VGA Settings Menu The VGA Settings menu includes the Timing Auto s...

Page 20: ...image up and down H position Horizontal Position Moves the screen image left and right Phase Adjusts the focus of the screen image Allows the user to remove any horizontal noise and sharpen the image...

Page 21: ...uage used in the menus and control screens Rotation allows the user to rotate the OSD by 0 90 180 or 270 A Mirrored setting is also available which is a horizontal reflection of the OSD OSD Position a...

Page 22: ...dvanced Setup submenu contains two additional settings Smart ISP flashes the video board firmware Do not activate without assistance from Hope Industrial technical support CVT Mode set to On will forc...

Page 23: ...TCH THE PROTECTIVE COATING ALWAYS USE A SOFT CLOTH PREFERABLY MADE OF COTTON All displays may be cleaned using any standard glass cleaner as long as there is no abrasive or oily content Vinegar or amm...

Page 24: ...oltage is 9 6 to 36 6 VDC No image on the screen and control s Power Indicator light is lit solid red Monitor is not powered on Press the Power button on the monitor for 1 2 seconds to turn the monito...

Page 25: ...unction may also be activated by pressing the Select SEL button outside of the OSD menu Fine tune the picture by manually adjusting the image using the settings in the OSD menu Analog signal is not a...

Page 26: ...the USB cable length exceed 5 meters USB cables have a 5 meter limitation and could cause no touch response if this is exceeded If using a Serial connection is the Serial cable plugged into the correc...

Page 27: ...ear collar compresses gasket against panel 5 16 maximum panel thickness held by 12 M5 studs Panel Rating with proper installation Built to IP65 IP66 standards NEMA UL Type 12 4 Black Powder Coated Fac...

Page 28: ...5 wire BNC adapter Input Signal Formats RGB Analog video 0 7 Vp p 75 Ohms Compatible sync modes Separate H V sync Composite sync Sync on Green DVI NOTE NTSC PAL composite input available call for det...

Page 29: ...tes a mouse Serial RS 232 and USB interface to host computer Electrical Monitor Input AC power models 100 to 240 VAC 1 5 0 75 A 60 50 Hz DC power models 9 6 to 36 6 VDC 2 5 to 0 65 A Class 2 or SELV L...

Page 30: ...E UKCA NOM Registration No NOM 019 SCFI 1998 Environmental IEC 60721 3 Reliability WEEE Registration No WEE DJ1859ZX for UK only Enclosure UL 50E File No E318630 Hazardous Location UL Rated for Hazard...

Page 31: ...ed we will give you a Return Material Authorization RMA number This RMA number must be conspicuously marked on the outside of the shipping box Hope Industrial Systems will not accept shipments not acc...

Page 32: ...44 0 20 7193 2618 HopeIndustrial fr Germany Phone 44 0 20 7193 2618 HopeIndustrial de Italy Phone 39 80 0740414 HopeIndustrial it Spain Phone 34 91 1438229 HopeIndustrial es EU Authorized Representati...