Failure Diagnostic
Disorder
Possible Cause
Troubleshooting
No battery inserted
Insert battery
battery empty
Charge the battery
The device is locked
Unlock the device in the expert menu / tool lock
Standby time of the LED foot light set to Change the time setting in the general menu
Foot LED defective
Send the device to the HONSEL repair service
Force set too high or too low
Set up the blind rivet nut or screw again
Stroke set too high or too low
Spindle time too short
Set up the blind rivet nut or screw again
Unwinding time too short
Extend the unwinding time in the expert menu / spindle setting
Device switched off / battery empty
Set device / change battery
Unscrewing mode set incorrectly
Threaded mandrel / sleeve were blocked
Check in the expert menu / unscrewing mode
Release the handle once without a blind rivet nut / screw
Defective pusher
Send the device to the HONSEL repair service
Remove the battery and reinsert it after 2 seconds
Software malfunction
Make software update
Remove the battery and reinsert it after 2 seconds
Software malfunction
Make software update
The service is due - note the ad
Send the device to the HONSEL repair service for maintenance
A warning has been received
Read the warning message on the OLED and act accordingly
see chapter 10
Device is in emergency mode
Read the warning message on the OLED and act accordingly
see chapter 10
After switching on, the device does not
make a proper calibration run
The protruding threaded mandrel / screw
length is changing
After switching on you have to wait
before you can work with the riveting tool
RGB LED lights up red continuously
RGB LED flashes red
Riveting tool does not respond
LED foot light does not light up or goes out
again immediately
Blind rivet nut or screw is not set correctly
Blind rivet nut or screw is not screwed on
correctly
Blind rivet nut or screw is not spindled off
correctly
The trigger or threaded mandrel / sleeve
do not trigger the spindle