Safety Warning

 

The  design

manufacture  and  test  are  all  up  to  the  safety 

standard IEC61010(safety demand of the electronic products), this 

manual  includes  the  safe  using  of  the  instrument  and  the  safety 

state of instrument, the warning and the safety rules that the users 

must comply. Please read the manual before use.   

Warning 

Please  read  carefully  and  understand  this  manual  before  using 

the instrument. 

Please  comply  the  regulation  of  the  manual  all  the  time,  and 

keep the manual for consultation. 

When  using  the  instrument  for  testing,  wrong  operation  can 

result in accident and instrument damage. 

The Company reserves the right to modify the instructions, if the

instructions are to change without notice

pls understand. 

The symbols on the instrument mean that in order to operate 

the instrument safely, the users are supposed to refer to the relating 

description in this manual. 

Danger

  is  in  order  to  avoid  the  probably  serious  or  fatal 

damage in some state and operation. 

Warning

 is in order to avoid the danger of electric-shocking.

Notice

  means  avoiding  the  damage  to  the  instrument  and 

accurate measuring. 

Danger 

  Please  don't  take  measurement  in  the  flammability  place,  the 

spark maybe result in explosion. 

  Please don't operate the instrument if it is wet of the instrument 

surface or of the user's hand. 

  When  testing  voltage,  it  probably  result  in  person  injury 

because of the short circuit of the metal part and the testing lead.

  Please don't exceed the maximum scope of the allowable range.

  Don't open the battery cover when testing. 

  When taking the insulated measurement, please don't touch the 

circuitry under test. 

Warning 

  If  there  is  abnormity  from  the  instrument,  please  stop  using.

For example: the instrument dilapidation or metal part exposure.

  Please  don't  rotate  the  Function/Selection  switch  when  the 

testing  lead  is  inserted  into  the  instrument  and  connected  to  the 

circuitry for testing. 

  Please  don't  install  any  substituting  parts  to  the  instrument  or 

carry on any unauthorized modification, instruments are sent back 

to the Hongda Company when maintaining. 

  Please  don't  replace  the  battery  when  the  instrument  is  in  the 

state of humidity. 

  Please  sure  the  connection  is  fastness  of  all  the  testing 

interfaces between the testing lead and the instrument. 

  Please  sure  the  instrument  is  turned  off  when  opening  the 

battery cover. 

Notice 

  Before  test,  please  sure  the  voltage  selector  switch  is  on  the 

proper location. 

  After test, please set the function switch to the range "OFF". If 

it is available for a long time, please take out the battery for storage

  Please  don't  put  the  instrument  in  the  place  of  high 

temperature

humidity

dew and strong light for a long time. 

  Please use the humid cloth or detergent to clean the instrument 

case. Don't use the friction material or solvent. 

  If the instrument is wet, please make it dry then storage.

Symbol 

The probability of electric-shocking 

The instrument has double insulation or reinforcing insulation 

Important operation(referring to the manual) 

1.Preface 

1.1    Thanks for use our products, you will get the 

comprehensive technology support and service from our company. 

1.2This manual is used for HDT20A/HDT20B insulation 

resistance tester. 

1.3    Before using the product, please read the manual 

carefully and keep it well for reference. 

1.4    The product is for high-voltage electric equipment tester, 

please accord to the manual description to operate. And comply 

strictly to the Nation's related regulations. For inappropriate 

operation, it will probably result in equipment damage or person 

safety danger.

 

1.5  

Please consult our company when there is any question 

as you read the manual or use the instrument. 

2.Characteristics 

2.1    HDT20A  HDT20B  is  a  electron  controlled  minitype 

instrument,  thereinto,  the  high  voltage  insulation  resistance  tester 

has three insulation resistance for voltage test. 

2.2      The design is up to the following safety standard: 

IEC 1010 

89/336/EEC(electromagnetism compatibility, Nov, 1992, EMC)

P73/23/EEC(product  safety  regulation:  Nov,  6

th

,  1979, 

low-voltage regulation: Feb,19th, 1973) 

2.3      Automatically release voltage function: 

2.4      Be  used  for  the  insulation  resistance  of  all  kinds  of 

electron equipment and insulation material, such as transformer

generator

cable

switch

electric equipment and so on. Be used for 

the  maintenance

test  and  check  of  all  the  series  of  electric 

equipment. 

2.5    Rated voltage variable 

HDT20A-- Rated voltage can be switched among  250V, 500V, 

1000V by knob switch. 

HDT20B--  Rated  voltage  can  be  switched  among  1000V, 

2500V by knob switch. 

2.6    High voltage indication 

There is the LED in the instrument(HV ON) indicating the high 

voltage work state. 

2.7    Low battery indication. 

2.8    Battery  drive,  removing  the  operation  of  hand-cranked 

generator. 

2.9    3 

1

/

digital display, reading clearly. 

2.10 The measurement range for HDT20A is 0.1M

Ω~

1999M

Summary of Contents for HDT20A

Page 1: ... sure the instrument is turned off when opening the battery cover Notice Before test please sure the voltage selector switch is on the proper location After test please set the function switch to the range OFF If it is available for a long time please take out the battery for storage Please don t put the instrument in the place of high temperature humidity dew and strong light for a long time Plea...

Page 2: ... 0 01GΩ 19 99GΩ 10 1000V 0 01GΩ 19 99GΩ 2500V 0 01GΩ 19 99GΩ ACV 750V 0 1 6 AC750V input impedance 1MΩ AC750V frequency response 50 200 Hz 4 Appearance 1 Line terminal L 2 Shield terminal G the end terminal of ACV measurement 3 The positive terminal of the ACV measurement 4 Earth terminal E 5 Backlight button 6 Range switch button 7 High volt startup button 8 External power jack 9 Instrument belt ...

Page 3: ...the instrument work normally If it is off it shows maybe the battery is low voltage or battery connection is abnormally When the measurement is begun there is reading on the meter header which is the insulation resistance value of the tested object under the current voltage For the HDT20A when the test value is less than 200M Ω suggest pressing the button using 200MΩ range can make the readings mo...

Page 4: ... Storage 10 1 Set the switch to the OFF position 10 2 When the instrument is available for a long time please take off the battery to avoid the electrolyte discharge resulting in rust 10 3 Please keep the case clean 10 4 instrument storage Storage temperature 10 50 Storage relative humidity 90 RH The place need no dust no causticity gas and well ventilated 11 Accessory HDT20A one plastic cover a p...