background image

AT2150/B Automotive Tester

User’s Guide

Introduction

AT2150/B series digital multimeter is a 3½ digital with precise

design, convenient for operation, stable performance and with
multi-functions measuring instrument. It was designed with new
style guarantees protective covering, large screen liquid crystal
display. It uniquely incorporate with back light valve features, so it
is suitable to be used in the obscure ray environment operation.
The ”VΩ” is equipped with PTC heat sensitive element at the input
terminal.

Therefore, the Function/Range switch has efficient

protection.

AT2150/B series digital multimeter can measure DC Current

and Voltage, Current, AC Current and Voltage, Resistor, Capacitor,
Temperature, Diode and Transistor, Open Circuit and Short Circuit.
In addition, AT2150/B digital multimeter is also suitable for vehicles.

Safety Precautions and Procedures

for your own safety, you must read and follow the procedure in this
instruction

manual.

don’t try to use it if the battery cover is not closed properly,
otherwise you may have the danger of electric shock.
make sure the insulation layer has not any damages before use it.
never input signal electronic level exceeding the limited value to
avoid electronic shock or damaging the instrument.
don’t turn the function/range switch when taking measurement.
the potential difference between the measurement public terminal
COM and earth can’t exceed 1000V to avoid electric short.
pay attention if the tested voltage is over DC 60V and AC 42V to
avoid electric shock
if there have a symbol

on the LCD display, it indicates low

battery. replace the battery to ensure measurement accuracy.
For the fuse, it must be replaced with an identical model if necessary.

International Symbols

DC Current or Voltage

AC Current or Voltage

Diode

Buzzer

Low Battery

Cautions

Double Insulation

Danger High Voltage

Rotational Speed

Closed Angle

Characteristic

Low power consumption CMOS double integration, A/D transform
integrated circuit, auto zero calibration, auto polarity display, low
battery and over range indication.
DC basic accuracy : +0.5% (3 1/2 digits)
Capacitor measurement : 1pF~200uF
Temperature measurement : -40ºC~1000ºC
Full range over-load protection function.
Have back-light valve features, it is suitable to be used in the obscure
ray environment operation.
Auto power off function: the meter will shut off automatically about
15 seconds after no performance.
Maximum display : 1999 (3 1/2 digits)

LCD display : 70 x 48mm big screen, high contrast, Word height :
28mm
Power : one 9V battery (NEDA 1604, 6F22 model or identical)
Low battery indication: mark

on display

Size : 192x88x42mm
Weight : approximate 400g (including battery and cover)
Environment conditions :
Operation temperature : 0ºC~40ºC

Relative humidity <85%

Storage Temperature : -10ºC~50ºC

Relative humidity <85%

Keeping accuracy temperature : 23ºC+5ºC
Relative humidity <75%

Technical Specifications

Accuracy : + (% r digit) one year warranty.
Environmental humidity : 23ºC+5ºC
Relative humidity : <75%

Closed Angle Gauge

Range

Accuracy

Resolution

1CYL

0-180.0º

+(1.2%+2)

0.1º

3CYL

0-120.0º

4CYL

0-90.0º

5CYL

0-72.0º

6CYL

0-60.0º

8CYL

0-45.0º

Overload protection : 250V, DC or AC peak value

Rotational Speed

Range

Accuracy

Resolution

1CYL

500-10000
rotation / min.

+(1.2%+2)

10 rotation /
min.

3CYL
4CYL
5CYL
6CYL
8CYL
Overload protection : 250V, DC or AC peak value

Duty Ratio

Range

Accuracy

Resolution

0-100.0%

+(1.2%+2)

0.1%

Overload protection : 250V, DC or AC peak value

DC Voltage

Range

Accuracy

Resolution

2V

+(0.5%+3)

1mV

20V

10mV

200V

100mV

1000V

+(0.8%+3)

1V

Input impedance : 10MΩ
Overload protection : 1000V, DC or AC peak value
AC Voltage

AC Voltage

Range

Accuracy

Resolution

2V

+(0.5%+3)

1mV

20V

10mV

200V

100mV

700V

+(0.8%+3) 1V

Input impedance: 10MΩ
Frequency range : 40Hz-400Hz
Overload protection : 1000V, DC or AC peak value
Display : Average value (Sine RMS)

DC current

Range

Accuracy

Resolution

200mA

+(1.2%+3)

100uA

20A

+(2%+3)

10mA

Overload protection : 0.2A/250V fuse
Maximum input current : 20A/15 second
Voltage drop measurement : Full-scale voltage drop : 200mV

AC current

Range

Accuracy

Resolution

200mA

+(1.2%+3)

100uA

20A

+(2%+5)

10mA

Overload protection : 0.2A/250V fuse
Maximum input current : 20A/15 second
Voltage drop measurement : Full-scale voltage drop : 200mV
Frequency range : 40Hz-400Hz
Display : Average value (Sine RMS)

Resistance

Range

Accuracy

Resolution

200Ω

+(0.8%+3)

0.1Ω

2kΩ

+(0.8%+2)

20kΩ

10Ω

200kΩ

100Ω

2MΩ

1kΩ

20MΩ

+(1%+5)

10kΩ

200MΩ

+(5%+10)

100kΩ

Overload protection : 250V DC or AC peak value
Open circuit voltage : <1V (2.8V in the 200MΩ)
Note : It is normal if the test lead short-circuit displays approx. 10
digits in the 200M Ω .

Please deduct these 10 digits when

measuring.

Capacitance

Range

Accuracy

Resolution

20nF

+(3%+3)

10pF

2uF

1nF

200uF

+(5%+3)

100nF

Frequency measurement : approx. 400Hz
Voltage measurement : approx. 40mV

Reviews: