background image

4 - 1

4

Data Editing

Prefix/Suffix Overview

When a bar code is scanned, additional information is sent to the host computer along with the bar code data.  This group of bar 
code data and additional, user-defined data is called a “message string.”  The selections in this section are used to build the 
user-defined data into the message string.

Prefix and Suffix characters are data characters that can be sent before and after scanned data.  You can specify if they should 
be sent with all symbologies, or only with specific symbologies.  The following illustration shows the breakdown of a message 
string:

Points to Keep In Mind

It is not necessary to build a message string.  The selections in this chapter are only used if you wish to alter the default 
settings.  

Default prefix = None.  Default suffix = None

.

A prefix or suffix may be added or cleared from one symbology or all symbologies.

You can add any prefix or suffix from the 

ASCII Conversion Chart (Code Page 1252),

 beginning on page A-3, plus Code 

I.D. and AIM I.D.

You can string together several entries for several symbologies at one time.

Enter prefixes and suffixes in the order in which you want them to appear on the output.

When setting up for specific symbologies (as opposed to all symbologies), the specific symbology ID value counts as an 
added prefix or suffix character.

The maximum size of a prefix or suffix configuration is 200 characters, which includes header information.

To Add a Prefix or Suffix:

Step 1.

Scan the 

Add Prefix

 or 

Add Suffix

 symbol (

page 4-2

).

Step 2.

Determine the 2 digit Hex value from the Symbology Chart (included in the 

Symbology Charts,

 beginning on page 

A-1) for the symbology to which you want to apply the prefix or suffix.  For example, for Code 128, Code ID is “j” and 
Hex ID is “6A”.

Step 3.

Scan the 2 hex digits from the 

Programming Chart

 inside the back cover of this manual or scan 

9

9

 for all 

symbologies.

Step 4.

Determine the hex value from the 

ASCII Conversion Chart (Code Page 1252),

 beginning on page A-3, for the prefix 

or suffix you wish to enter. 

Note: To add the Code I.D., scan 

5

C

8

0

.

To add AIM I.D., scan 

5

,

 C

,

 8

,

 1

.

To add a backslash (\), scan 

5

C

5

C

.

To add a backslash (\), you must scan 5C twice – once to create the leading backslash and then to create the 
backslash itself.

Step 5.

Scan the 2 digit hex value from the 

Programming Chart

 inside the back cover of this manual.

Step 6.

Repeat Steps 4 and 5 for every prefix or suffix character.

Step 7.

Scan 

Save

 to exit and save, or scan 

Discard

 to exit without saving.

Repeat Steps 1-6 to add a prefix or suffix for another symbology.

Prefix

S

c

a

nned D

a

t

a

Su

ffix

1-11
alpha numeric &
control characters

variable length

1-11
alpha numeric &
control characters

Summary of Contents for Youjie HH660

Page 1: ...Youjie HH660 Area Imaging Scanner User s Guide ...

Page 2: ...l HII disclaims all responsibility for the selection and use of software and or hardware to achieve intended results This document contains proprietary information that is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated into another language without the prior written consent of HII Copyright 2016 Honeywell International Inc All ri...

Page 3: ... Plug and Play 2 1 Keyboard Wedge 2 1 Laptop Direct Connect 2 1 RS232 Serial Port 2 1 RS485 2 2 RS485 Packet Mode 2 2 USB IBM SurePos 2 3 USB PC or Macintosh Keyboard 2 3 USB HID 2 4 USB Serial 2 4 CTS RTS Emulation 2 4 ACK NAK Mode 2 4 Remote MasterMind for USB 2 4 Verifone Ruby Terminal Default Settings 2 5 Gilbarco Terminal Default Settings 2 5 Honeywell Bioptic Aux Port Configuration 2 5 Datal...

Page 4: ...d Read 3 2 Beeper Volume Good Read 3 2 Beeper Pitch Good Read 3 2 Beeper Pitch Error 3 3 Beeper Duration Good Read 3 3 LED Good Read 3 3 Number of Beeps Good Read 3 4 Number of Beeps Error 3 4 Good Read Delay 3 4 User Specified Good Read Delay 3 4 Manual Trigger Mode 3 5 LED Illumination Manual Trigger 3 5 Serial Trigger Mode 3 5 Read Time Out 3 5 Presentation Mode 3 5 Idle Illumination Presentati...

Page 5: ...ge Return Suffix to All Symbologies 4 2 Prefix Selections 4 2 Suffix Selections 4 2 Function Code Transmit 4 3 Intercharacter Interfunction and Intermessage Delays 4 3 Intercharacter Delay 4 3 User Specified Intercharacter Delay 4 3 Interfunction Delay 4 4 Intermessage Delay 4 4 Chapter 5 Data Formatting Data Format Editor Introduction 5 1 Add a Data Format 5 1 Other Programming Selections 5 2 Ter...

Page 6: ...ith Extended Coupon Code 6 19 Coupon GS1 DataBar Output 6 20 UPC E0 6 20 UPC E1 6 22 EAN JAN 13 6 23 Convert UPC A to EAN 13 6 23 ISBN Translate 6 25 EAN JAN 8 6 25 MSI 6 27 GS1 DataBar Omnidirectional 6 29 GS1 DataBar Limited 6 29 GS1 DataBar Expanded 6 30 Codablock A 6 30 Codablock F 6 31 PDF417 6 32 MacroPDF417 6 32 MicroPDF417 6 33 GS1 Composite Codes 6 33 UPC EAN Version 6 34 GS1 Emulation 6 ...

Page 7: ... from the Web 7 2 Resetting the Factory Defaults 7 3 Chapter 8 Serial Programming Commands Conventions 8 1 Menu Command Syntax 8 1 Query Commands 8 1 Responses 8 2 Trigger Commands 8 3 Resetting the Custom Defaults 8 3 Menu Commands 8 3 Chapter 9 Product Specifications Youjie HH660 Scanner Product Specifications 9 1 Standard Cable Pinouts 9 2 USB 9 2 Chapter 10 Maintenance and Troubleshooting Repa...

Page 8: ...arts A 1 Linear Symbologies A 1 2D Symbologies A 2 Postal Symbologies A 2 ASCII Conversion Chart Code Page 1252 A 3 Lower ASCII Reference Table A 4 ISO 2022 ISO 646 Character Replacements A 7 Unicode Key Maps A 9 Sample Symbols Programming Chart ...

Page 9: ...rld To obtain warranty or non warranty service please visit www honeywellaidc com and select the Support tab to see your region s instructions on how to obtain a Return Material Authorization number RMA You should do this prior to returning the product Limited Warranty Refer to www honeywellaidc com warranty_information for your product s warranty information Send Feedback Your feedback is crucial...

Page 10: ...viii ...

Page 11: ...n containing the product take the following steps Check for damage during shipment Report damage immediately to the carrier who delivered the carton Make sure the items in the carton match your order Save the shipping container for later storage or shipping Connecting the Device Connecting with USB A scanner can be connected to the USB port of a computer 1 Connect the appropriate interface cable t...

Page 12: ...k on The scanner beeps 4 Verify the scanner operation by scanning a bar code from the Sample Symbols in the back of this manual The scanner beeps once The unit defaults to an IBM PC AT and compatibles keyboard wedge interface with a USA keyboard A carriage return CR suffix is added to bar code data Connecting with RS232 Serial Port 1 Turn off power to the terminal computer 2 Connect the appropriat...

Page 13: ...nner can be connected for an IBM POS terminal interface 1 Connect the appropriate interface cable to the device then to the computer 2 Turn the terminal computer power back on The scanner beeps 3 Verify the scanner operation by scanning a bar code from the Sample Symbols in the back of this manual The scanner beeps once For further RS485 settings refer to RS485 page 2 2 ...

Page 14: ...ility to scan menu codes you can use the Menu Bar Code Security settings Please contact the nearest techni cal support office see Customer Support on page vii for further information Setting Custom Defaults You have the ability to create a set of menu commands as your own custom defaults To do so scan the Set Custom Defaults bar code below before scanning the menu commands for your custom defaults...

Page 15: ...ow This is the recommended default bar code for most users It resets the scanner to the custom default settings If there are no custom defaults it will reset the scanner to the factory default settings Any settings that have not been specified through the custom defaults will be defaulted to the factory default settings Activate Custom Defaults ...

Page 16: ...1 6 ...

Page 17: ...ge return CR suffix Laptop Direct Connect For most laptops scanning the Laptop Direct Connect bar code allows operation of the scanner in parallel with the integral keyboard The following Laptop Direct Connect bar code also programs a carriage return CR suffix and turns on Emulate External Keyboard page 2 16 RS232 Serial Port The RS232 Interface bar code is used when connecting to the serial port ...

Page 18: ... RS485 Packet Mode The following selection allows you to break up large bar code data into smaller packets on an IBM POS terminal To break up large bar codes into small packets scan the Packet Mode On bar code below Scan the Packet Mode Off bar code if you want large bar code data to be sent to the host in a single chunk Default Packet Mode Off Symbology Suffix Symbology Suffix EAN 8 0C Code 39 00...

Page 19: ...ce Note After scanning one of these codes you must power cycle the cash register Each bar code above also programs the following suffixes for each symbology USB PC or Macintosh Keyboard Scan one of the following codes to program the scanner for USB PC Keyboard or USB Macintosh Keyboard Scanning these codes also adds a CR and LF Symbology Suffix Symbology Suffix EAN 8 0C Code 39 00 0A 0B EAN 13 16 ...

Page 20: ...acintosh computers recognize the scanner as a USB CDC class device and automatically uses a class driver Note No extra configuration e g baud rate is necessary CTS RTS Emulation ACK NAK Mode Remote MasterMind for USB When using a USB interface you may wish to configure your scanner to communicate with Remote MasterMind Scanner Man agement Software ReM Scan the ReM On bar code to communicate with R...

Page 21: ...inal This bar code sets the baud rate to 2400 bps and the data format to 7 data bits even parity 2 stop bits It also adds a carriage return CR suffix and programs the follow ing prefixes for each symbology Honeywell Bioptic Aux Port Configuration Scan the following Plug and Play code to program the scanner for a Honeywell bioptic scanner auxiliary port configuration This bar code sets the baud rat...

Page 22: ...uxiliary port configuration The fol lowing prefixes are programmed for each symbology Wincor Nixdorf Terminal Default Settings Scan the following Plug and Play code to program the scanner for a Wincor Nixdorf terminal This bar code sets the baud rate to 9600 bps and the data format to 8 data bits no parity 1 stop bit Symbology Prefix Symbology Prefix UPC A A Interleaved 2 of 5 b UPC E E0 Code 128 ...

Page 23: ...e baud rate to 9600 bps and the data format to 8 data bits odd parity 1 stop bit The following prefixes are programmed for each symbology Symbology Prefix Symbology Prefix Aztec Code V Interleaved 2 of 5 I Codabar N MaxiCode T Code 93 L MicroPDF417 S Code 128 K PDF417 Q Data Matrix R QR Code U EAN 8 B Straight 2 of 5 IATA H EAN 13 A UPC A A0 GS1 DataBar E UPC E C GS1 128 P All other bar codes M Sy...

Page 24: ...yboard country Scan the appropriate bar code below to change the layout By default national character replacements are used for the following characters See ISO 2022 ISO 646 Character Replacements on page A 7 to view the character replacements for each country Keyboard Countries United States Albania Azeri Cyrillic Azeri Latin Belarus Belgium Bosnia Brazil Brazil MS Bulgaria Cyrillic ...

Page 25: ...2 9 Keyboard Countries Continued Bulgaria Latin Canada French legacy Canada French Canada Multilingual Croatia Czech Czech Programmers Czech QWERTY Czech QWERTZ Denmark Dutch Netherlands ...

Page 26: ...2 10 Keyboard Countries Continued Estonia Faroese Finland France Gaelic Germany Greek Greek 220 Latin Greek 220 Greek 319 Latin Greek 319 ...

Page 27: ...2 11 Keyboard Countries Continued Greek Latin Greek MS Greek Polytonic Hebrew Hungarian 101 key Hungary Iceland Irish Italian 142 Italy Japan ASCII ...

Page 28: ...2 12 Keyboard Countries Continued Kazakh Kyrgyz Cyrillic Latin America Latvia Latvia QWERTY Lithuania Lithuania IBM Macedonia Malta Mongolian Cyrillic Norway ...

Page 29: ...2 13 Keyboard Countries Continued Poland Polish 214 Polish Programmers Portugal Romania Russia Russian MS Russian Typewriter SCS Serbia Cyrillic Serbia Latin ...

Page 30: ...2 14 Keyboard Countries Continued Slovakia Slovakia QWERTY Slovakia QWERTZ Slovenia Spain Spanish variation Sweden Switzerland French Switzerland German Tatar Turkey F ...

Page 31: ...wing Keyboard Style settings Default Regular Regular is used when you normally have the Caps Lock key off Caps Lock is used when you normally have the Caps Lock key on Keyboard Countries Continued Turkey Q Ukrainian United Kingdom United States Dvorak United States Dvorak left United Stated Dvorak right United States International Uzbek Cyrillic Regular Caps Lock ...

Page 32: ...if you do not have an external keyboard IBM AT or equivalent Note After scanning the Emulate External Keyboard bar code you must power cycle your computer Keyboard Conversion Alphabetic keyboard characters can be forced to be all upper case or all lowercase So if you have the following bar code abc569GK you can make the output ABC569GK by scanning Convert All Characters to Upper Case or to abc569g...

Page 33: ...CII Mode On The scanner sends key combinations for ASCII control characters for values 00 1F Windows is the preferred mode All keyboard country codes are supported DOS mode is a legacy mode and it does not support all key board country codes New users should use the Windows mode Refer to ASCII Conversion Chart Code Page 1252 page A 3 for CTRL ASCII Values Windows Mode Prefix Suffix Off The scanner...

Page 34: ...his selection can be used if you have an IBM AT style terminal and the system is dropping characters Default Off RS232 Modifiers RS232 Baud Rate Baud Rate sends the data from the scanner to the terminal at the specified rate The host terminal must be set for the same baud rate as the scanner Default 115200 Turbo Mode On Turbo Mode Off Numeric Keypad Mode On Numeric Keypad Mode Off Automatic Direct...

Page 35: ...s 0 through 7F decimal text digits and punctuation select 7 data bits For applications that require use of the full ASCII set select 8 data bits per character Default 8 Stop Bits sets the stop bits at 1 or 2 Default 1 Parity provides a means of checking character bit patterns for validity Default None 1200 2400 4800 9600 19200 38400 57 600 115 200 7 Data 1 Stop Parity Even ...

Page 36: ...de back cover of this manual then scanning Save The range is 0 to 300 seconds Default 0 seconds no time out always on RS232 Handshaking RS232 Handshaking allows control of data transmission from the scanner using software commands from the host device When RTS CTS is turned Off no data flow control is used Flow Control No Timeout The scanner asserts RTS when it has data to send and will wait indef...

Page 37: ...you want to wait for CTS from the host Set the length in milliseconds for a timeout by scanning the bar code below then setting the timeout from 1 5100 millisec onds by scanning digits from the inside back cover then scanning Save XON XOFF Standard ASCII control characters can be used to tell the scanner to start sending data XON XOFF On or to stop sending data XON XOFF Off When the host sends the...

Page 38: ...nners and bioptic scanners Note The scanner s baud rate must be set to 38400 and the RS232 timeout must be set to 3000 in order to communicate with a bioptic scanner See RS232 Baud Rate on page 2 18 and RS232 Timeout on page 2 21 for further information Scanner Bioptic Packet Mode Packet Mode On must be scanned to set the scanner s format so it is compatible with a bioptic scanner Default Packet M...

Page 39: ...to set the length in milliseconds for a timeout for a bioptic scanner s ACK NAK response Scan the bar code below then set the timeout from 1 30 000 milliseconds by scanning digits from the inside back cover then scanning Save Default 5100 ACK NAK Timeout ...

Page 40: ...2 24 ...

Page 41: ... BEL On bar code below the scanner will beep every time a BEL character is received from the host Default Beep on BEL Off Trigger Click To hear an audible click every time the scanner trigger is pressed scan the Trigger Click On bar code below Scan the Trigger Click Off code if you don t wish to hear the click This feature has no effect on serial or automatic triggering Default Trigger Click Off P...

Page 42: ...rror and menu beeps are still audible Default Beeper Good Read On Beeper Volume Good Read The beeper volume codes modify the volume of the beep the scanner emits on a good read Default High Beeper Pitch Good Read The beeper pitch codes modify the pitch frequency of the beep the scanner emits on a good read Default Medium Beeper Good Read Off Beeper Good Read On Low Medium High Off Low 1600 Hz Medi...

Page 43: ...z Beeper Duration Good Read The beeper duration codes modify the length of the beep the scanner emits on a good read Default Normal LED Good Read The LED indicator can be programmed On or Off in response to a good read Default On High 4200 Hz Razz 250 Hz Medium 3250 Hz High 4200 Hz Normal Beep Short Beep Short Beep LED Good Read On LED Good Read Off ...

Page 44: ...rogrammed from 1 9 For example if you program this option to have five error beeps there will be five error beeps and five LED flashes in response to an error To change the number of error beeps scan the bar code below and then scan a digit 1 9 bar code and the Save bar code on the Programming Chart inside the back cover of this manual Default 1 Good Read Delay This sets the minimum amount of time...

Page 45: ...l the deactivate command is sent The scanner can also be set to turn itself off after a specified time has elapsed see Read Time Out which follows Read Time Out Use this selection to set a time out in milliseconds of the scanner s trigger when using serial commands to trigger the scanner Once the scanner has timed out you can activate the scanner either by pressing the trigger or using a serial tr...

Page 46: ...f sensitivity from 0 20 from the inside back cover and Save 0 is the most sensitive setting and 20 is the least sensitive Default 1 Presentation Centering Use Presentation Centering to narrow the scanner s field of view when it is in the stand to make sure the scanner reads only those bar codes intended by the user For instance if multiple codes are placed closely together Presentation Center ing ...

Page 47: ...s completely through the centering window Scan Presentation Centering On then scan one of the following bar codes to change the top bottom left or right of the centering window Then scan the percent you want to shift the centering window using digits on the inside back cover of this manual Scan Save Default Presentation Centering 40 for Top and Left 60 for Bottom and Right 0 Bar Code 1 Bar Code 2 ...

Page 48: ... Codes This setting improves the scanner s ability to read damaged or badly printed linear bar codes When Poor Quality 1D Reading On is scanned poor quality linear bar code reading is improved but the scanner s snappiness is decreased mak ing it less aggressive when reading good quality bar codes This setting does not affect 2D bar code reading Default Poor Quality 1D Reading Off Left of Presentat...

Page 49: ... system The scanner remains on scanning and decoding bar codes but the bar code data is not transmitted until the trigger is pressed When CodeGate is Off bar code data is transmitted when it is decoded Default CodeGate Off Out of Stand Mobile Phone Read Mode When this mode is selected your scanner is optimized to read bar codes from mobile phone or other LED displays However the speed of scanning ...

Page 50: ...ack cover and Save Default 5 000 ms Reread Delay This sets the time period before the scanner can read the same bar code a second time Setting a reread delay protects against accidental rereads of the same bar code Longer delays are effective in minimizing accidental rereads Use shorter delays in applications where repetitive bar code scanning is required Reread Delay only works when in Presentati...

Page 51: ...aracter sent from the host to trigger the scanner to begin scanning When the activation character is received the scanner continues scanning until either the Character Activation Timeout page 3 12 the deactivation character is received see Deactivation Character on page 3 13 or a bar code is transmitted Scan the following On bar code to use char acter activation then use Activation Character follo...

Page 52: ...imer remains on after a good read Default End Character Activation After Good Read Character Activation Timeout You can set a timeout for the length of time the aimer remains on and attempting to decode bar codes when using Charac ter Activation Mode Set the length in milliseconds for a timeout by scanning the following bar code then setting the time out from 1 65535 milliseconds by scanning digit...

Page 53: ...hese codes to set the time between when the trigger is pulled and when the picture is taken During the delay time the aiming light will appear but the LEDs won t turn on until the delay time is over Default Off User Specified Aimer Delay If you want to set your own length for the duration of the delay scan the bar code below then set the time out by scanning digits 0 4 000 ms from the Programming ...

Page 54: ...ht of Centering Window bar codes In the example below the white box is the centering window The centering window has been set to 20 left 30 right 8 top and 25 bottom Since Bar Code 1 passes through the centering window it will be read Bar Code 2 does not pass through the centering window so it will not be read Note A bar code needs only to be touched by the centering window in order to be read It ...

Page 55: ...erse is used to allow the scanner to read bar codes that are inverted The Video Reverse Off bar code below is an example of this type of bar code Scan Video Reverse Only to read only inverted bar codes Scan Video Reverse and Stan dard Bar Codes to read both types of codes Note After scanning Video Reverse Only menu bar codes cannot be read You must scan Video Reverse Off or Video Reverse and Stand...

Page 56: ...e down Use the working orientation settings if your direction sensitive codes will not usually be presented upright to the scanner Default Upright Video Reverse and Standard Bar Codes Video Reverse Off Upright Vertical Top to Bottom Rotate CW 90 Upside Down Vertical Bottom to Top Rotate CCW 90 Upright Vertical Bottom to Top Upside Down ...

Page 57: ...3 17 Vertical Top to Bottom ...

Page 58: ...3 18 ...

Page 59: ...ymbologies the specific symbology ID value counts as an added prefix or suffix character The maximum size of a prefix or suffix configuration is 200 characters which includes header information To Add a Prefix or Suffix Step 1 Scan the Add Prefix or Add Suffix symbol page 4 2 Step 2 Determine the 2 digit Hex value from the Symbology Chart included in the Symbology Charts beginning on page A 1 for ...

Page 60: ...c character from a symbology When you Clear All Prefixes Suffixes all the prefixes or suffixes for a symbology are deleted Step 1 Scan the Clear One Prefix or Clear One Suffix symbol Step 2 Determine the 2 digit Hex value from the Symbology Chart included in the Symbology Charts beginning on page A 1 for the symbology from which you want to clear the prefix or suffix Step 3 Scan the 2 digit hex va...

Page 61: ...ransmission of each character of scanned data Scan the Intercharacter Delay bar code below then scan the number of 5ms delays and the Save bar code using the Programming Chart inside the back cover of this manual To remove this delay scan the Intercharacter Delay bar code then set the number of delays to 0 Scan the Save bar code using the Programming Chart inside the back cover of this manual Note...

Page 62: ...ual To remove this delay scan the Interfunction Delay bar code then set the number of delays to 0 Scan the Save bar code using the Programming Chart inside the back cover of this manual Intermessage Delay An intermessage delay of up to 5000 milliseconds in 5ms increments may be placed between each scan transmission Scan the Intermessage Delay bar code below then scan the number of 5ms delays and t...

Page 63: ... have changed data format settings and wish to clear all formats and return to the factory defaults scan the Default Data Format code below Add a Data Format Step 1 Scan the Enter Data Format symbol page 5 2 Step 2 Select Primary Alternate Format Determine if this will be your primary data format or one of 3 alternate formats This allows you to save a total of 4 different data formats To program y...

Page 64: ...at for one symbology If you are clearing the primary format scan 0 from the Programming Chart inside the back cover of this manual If you are clearing an alternate format scan 1 2 or 3 depending on the format you are clearing Scan the Terminal Type and Code I D see Symbology Charts on page A 1 and the bar code data length for the specific data format that you want to delete All other formats remai...

Page 65: ...onversion Chart Code Page 1252 beginning on page A 3 for decimal hex and character codes F2 Example Send a number of characters Send the first 10 characters from the bar code above followed by a carriage return Command string F2100D F2 is the Send a number of characters command 10 is the number of characters to send 0D is the hex value for a CR The data is output as 1234567890 F2 and F1 Example Sp...

Page 66: ...rsor is moved forward to one position past the last input message character included Syntax E9nn where nn stands for the numeric value 00 99 for the number of characters that will not be sent at the end of the message Insert a character multiple times F4 Send xx character nn times in the output message leaving the cursor in the current position Syntax F4xxnn where xx stands for the insert characte...

Page 67: ...pulate bar codes that begin with a 1 Search for bar codes that begin with a 1 If a bar code matches move the cursor back to the beginning of the data and send 6 characters followed by a carriage return Using the bar code above Command string FE31F7F2060D FE is the Compare characters command 31 is the hex value for 1 F7 is the Move the cursor to the beginning command F2 is the Send a number of char...

Page 68: ... character Syntax E6xx where xx stands for the search character s hex value for its ASCII code Refer to the ASCII Conversion Chart Code Page 1252 beginning on page A 3 for decimal hex and character codes E6 Example Remove zeroes at the beginning of bar code data This example shows a bar code that has been zero filled You may want to ignore the zeroes and send all the data that follows E6 searches ...

Page 69: ...suppress filter and clear all suppressed characters Syntax FC Replace characters E4 Replaces up to 15 characters in the output message without moving the cursor Replacement continues until the E5 command is encountered Syntax E4nnxx1xx2yy1yy2 zz1zz2 where nn is the total count of the number of characters in the list characters to be replaced plus replacement characters xx1 defines characters to be...

Page 70: ...k for a number command F1 is the Send all characters command 0D is the hex value for a CR If this bar code is read the next data format if there is one will be used on the data If there is no other format the format fails and the raw data is output as AB1234 If this bar code is read the data is output as 1234AB CR Check for non numeric character ED Check to make sure there is a non numeric ASCII c...

Page 71: ...to your data format and prefixes and suffixes are transmitted Data Format Required Keep Prefix Suffix Scanned data is modified according to your data format and prefixes and suffixes are transmitted Any data that does not match your data format requirements generates an error tone and the data in that bar code is not transmitted Default Data Formatter On Not Required Keep Prefix Suffix Primary Alt...

Page 72: ...5 10 Data Format 3 ...

Page 73: ...f some of the bar code symbologies You may wish to set the same value for min imum and maximum length to force the scanner to read fixed length bar code data This helps reduce the chances of a misread All Symbologies Interleaved 2 of 5 Aztec Code Korea Post China Post Hong Kong 2 of 5 Matrix 2 of 5 Chinese Sensible Han Xin Code MaxiCode Codabar MicroPDF417 Codablock A MSI Codablock F NEC 2 of 5 Co...

Page 74: ...All Codabar Settings Codabar On Off Codabar Start Stop Characters Start Stop characters identify the leading and trailing ends of the bar code You may either transmit or not transmit Start Stop characters Default Don t Transmit Codabar Check Character Codabar check characters are created using different modulos You can program the scanner to read only Codabar bar codes with Modulo 16 check charact...

Page 75: ...e two messages are concatenated into one with the D characters omitted Select Require to prevent the scanner from decoding a single D Codabar symbol without its companion This selection has no effect on Codabar symbols without Stop Start D characters Codabar Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 1 for additional information ...

Page 76: ...smits bar code data with or without a check character When Check Character is set to Validate but Don t Transmit the unit only reads Code 39 bar codes printed with a check character but will not transmit the check character with the scanned data When Check Character is set to Validate and Transmit the scanner only reads Code 39 bar codes printed with a check character and will transmit this charac...

Page 77: ...o the host computer When the scanner encounters a Code 39 bar code with the append trigger character s it buffers Code 39 bar codes until it reads a Code 39 bar code that does not have the append trigger The data is then transmitted in the order in which the bar codes were read FIFO Default Off Code 32 Pharmaceutical PARAF Code 32 Pharmaceutical is a form of the Code 39 symbology used by Italian p...

Page 78: ...If this is the case scan the bar code below select the code page with which the bar codes were created see ISO 2022 ISO 646 Character Replacements on page A 7 and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual The data characters should then appear properly NUL U DLE P SP SPACE 0 0 V P P W p P SOH A DC1 Q A 1 1 A A Q Q a A q Q STX B DC2 ...

Page 79: ...eck digit with the scanned data When Check Digit is set to Validate and Transmit the scanner only reads Interleaved 2 of 5 bar codes printed with a check digit and will transmit this digit at the end of the scanned data Default No Check Digit Interleaved 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 1 for additional informati...

Page 80: ...ansmit the unit only reads NEC 2 of 5 bar codes printed with a check digit but will not transmit the check digit with the scanned data When Check Digit is set to Validate and Transmit the scanner only reads NEC 2 of 5 bar codes printed with a check digit and will transmit this digit at the end of the scanned data Default No Check Digit Maximum Message Length On Off No Check Digit Validate but Don ...

Page 81: ...Default 4 Maximum Default 80 Code 93 Default All Code 93 Settings Code 93 On Off Code 93 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 1 for additional information Minimum and Maximum lengths 0 80 Minimum Default 0 Maximum Default 80 Minimum Message Length Maximum Message Length On Off Minimum Message Length Maximum Message Length ...

Page 82: ...ode 93 bar code that starts with a character other than a space Default Off Code 93 Code Page Code pages define the mapping of character codes to characters If the data received does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code belo...

Page 83: ...of 5 Industrial On Off Straight 2 of 5 Industrial Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 1 for additional information Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 On Off Minimum Message Length Maximum Message Length ...

Page 84: ...f 5 IATA On Off Straight 2 of 5 IATA Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 1 for additional information Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 On Off Minimum Message Length Maximum Message Length ...

Page 85: ...Matrix 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 1 for additional information Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 On Off Minimum Message Length Maximum Message Length ...

Page 86: ...de 11 bar codes Default Two Check Digits Code 11 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 1 for additional information Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 On Off One Check Digit Two Check Digits Minimum Message Length Maximum Message Length ...

Page 87: ...rent recommendation to use Code 128 due to its high degree of security and its space efficient design 3 a variation of Code 128 that supports concatenation of neigh boring symbols and 4 the standard layout for bar codes on a blood product label Use the bar codes below to turn concat enation on or off Default Off Code 128 Message Length Scan the bar codes below to change the message length Refer to...

Page 88: ...lt On Code 128 Code Page Code pages define the mapping of character codes to characters If the data received does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see ISO ...

Page 89: ...th Refer to Message Length Description page 6 1 for additional information Minimum and Maximum lengths 1 80 Minimum Default 1 Maximum Default 80 UPC A Default All UPC A Settings UPC A On Off Note To convert UPC A bar codes to EAN 13 see Convert UPC A to EAN 13 on page 6 23 On Off Minimum Message Length Maximum Message Length On Off ...

Page 90: ... system digit of a U P C symbol is normally transmitted at the beginning of the scanned data but the unit can be programmed so it will not transmit it Default On UPC A Addenda This selection adds 2 or 5 digits to the end of all scanned UPC A data Default Off for both 2 Digit and 5 Digit Addenda On Off On Off 2 Digit Addenda On 2 Digit Addenda Off 5 Digit Addenda On 5 Digit Addenda Off ...

Page 91: ...le UPC A and EAN 13 with Extended Coupon Code When left on the default setting Off the scanner treats Coupon Codes and Extended Coupon Codes as single bar codes If you scan the Allow Concatenation code when the scanner sees the coupon code and the extended coupon code in a single scan it transmits both as one symbology Otherwise it transmits the first coupon code it reads If you scan the Require C...

Page 92: ... DataBar code data Default GS1 Out put Off UPC E0 Default All UPC E Settings UPC E0 On Off Most U P C bar codes lead with the 0 number system To read these codes use the UPC E0 On selection If you need to read codes that lead with the 1 number system use UPC E1 page 6 22 Default On UPC E0 Expand UPC E Expand expands the UPC E code to the 12 digit UPC A format Default Off GS1 Output Off GS1 Output ...

Page 93: ...om the bar code and the data from the addenda When turned Off there is no space Default On UPC E0 Check Digit Check Digit specifies whether the check digit should be transmitted at the end of the scanned data or not Default On UPC E0 Leading Zero This feature allows the transmission of a leading zero 0 at the beginning of scanned data To prevent transmission scan Off Default On Required Not Requir...

Page 94: ...git and 5 Digit Addenda UPC E1 Most U P C bar codes lead with the 0 number system For these codes use UPC E0 page 6 20 If you need to read codes that lead with the 1 number system use the UPC E1 On selection Default Off 2 Digit Addenda On 2 Digit Addenda Off 5 Digit Addenda On 5 Digit Addenda Off UPC E1 On UPC E1 Off ...

Page 95: ...e converted to 13 digit EAN 13 codes by adding a zero to the front When Do not Convert UPC A is selected UPC A codes are read as UPC A EAN JAN 13 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not Default On On Off UPC A Converted to EAN 13 Do not Convert UPC A On Off ...

Page 96: ...hat have addenda Default Not Required EAN JAN 13 Addenda Separator When this feature is On there is a space between the data from the bar code and the data from the addenda When turned Off there is no space Default On Note If you want to enable or disable EAN13 with Extended Coupon Code refer to UPC A EAN 13 with Extended Coupon Code page 6 19 2 Digit Addenda On 2 Digit Addenda Off 5 Digit Addenda...

Page 97: ...o their equivalent ISBN number format Default Off EAN JAN 8 Default All EAN JAN 8 Settings EAN JAN 8 On Off EAN JAN 8 Check Digit This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not Default On On Off On Off On Off ...

Page 98: ...red is scanned the scanner will only read EAN JAN 8 bar codes that have addenda Default Not Required EAN JAN 8 Addenda Separator When this feature is On there is a space between the data from the bar code and the data from the addenda When turned Off there is no space Default On 2 Digit Addenda On 2 Digit Addenda Off 5 Digit Addenda On 5 Digit Addenda Off Required Not Required On Off ...

Page 99: ...rinted with the specified type check character s and will transmit the character s at the end of the scanned data When Check Character is set to Validate Type 10 11 but Don t Transmit the unit will only read MSI bar codes printed with the specified type check character s but will not transmit the check character s with the scanned data On Off Validate Type 10 but Don t Transmit Validate Type 10 an...

Page 100: ...ngth Refer to Message Length Description page 6 1 for additional information Minimum and Maximum lengths 4 48 Minimum Default 4 Maximum Default 48 Validate Type 11 then Type 10 Character and Transmit Disable MSI Check Characters Minimum Message Length Maximum Message Length ...

Page 101: ... DataBar Omnidirectional Default All GS1 DataBar Omnidirectional Settings GS1 DataBar Omnidirectional On Off GS1 DataBar Limited Default All GS1 DataBar Limited Settings GS1 DataBar Limited On Off On Off On Off ...

Page 102: ...Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 1 for additional information Minimum and Maximum lengths 4 74 Minimum Default 4 Maximum Default 74 Codablock A Default All Codablock A Settings Codablock A On Off On Off Minimum Message Length Maximum Message Length On Off ...

Page 103: ... Maximum Default 600 Codablock F Default All Codablock F Settings Codablock F On Off Codablock F Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 1 for additional information Minimum and Maximum lengths 1 2048 Minimum Default 1 Maximum Default 2048 Minimum Message Length Maximum Message Length On Off Minimum Message Length Maximum Mess...

Page 104: ...al information Minimum and Maximum lengths 1 2750 Minimum Default 1 Maximum Default 2750 MacroPDF417 MacroPDF417 is an implementation of PDF417 capable of encoding very large amounts of data into multiple PDF417 bar codes When this selection is enabled these multiple bar codes are assembled into a single data string Default On On Off Minimum Message Length Maximum Message Length On Off ...

Page 105: ... 6 1 for additional information Minimum and Maximum lengths 1 366 Minimum Default 1 Maximum Default 366 GS1 Composite Codes Linear codes are combined with a unique 2D composite component to form a new class called GS1 Composite symbology GS1 Composite symbologies allow for the co existence of symbologies already in use Default Off On Off Minimum Message Length Maximum Message Length On Off ...

Page 106: ...nclude UPC A and UPC E EAN 13 and EAN 8 ITF 14 GS1 128 and GS1 128 DataBar and GS1 Composites Any application that accepts GS1 data can be simplified since it only needs to recog nize one data carrier type If GS1 128 Emulation is scanned all retail codes U P C UPC E EAN8 EAN13 are expanded out to 16 digits If the AIM ID is enabled the value will be the GS1 128 AIM ID C1 see Symbology Charts on pag...

Page 107: ...he Code 39 linear component The MicroPDF417 component can only be decoded if TLC39 On is selected The linear component may be decoded as Code 39 even if TLC39 is off Default Off QR Code Default All QR Code Settings QR Code On Off This selection applies to both QR Code and Micro QR Code GS1 DataBar Emulation GS1 Code Expansion Off EAN8 to EAN13 Conversion GS1 Emulation Off On Off On Off ...

Page 108: ...e proper number of codes is reached the data is output in the order specified in the bar codes Default On QR Code Page QR Code pages define the mapping of character codes to characters If the data received does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the...

Page 109: ... bar code with the append trigger character s it buf fers the number of Data Matrix bar codes determined by information encoded in those bar codes Once the proper number of codes is reached the data is output in the order specified in the bar codes Default On Data Matrix Code Page Data Matrix Code pages define the mapping of character codes to characters If the data received does not display with ...

Page 110: ... data characters should then appear properly MaxiCode Default All MaxiCode Settings MaxiCode On Off MaxiCode Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 1 for additional information Minimum and Maximum lengths 1 150 Minimum Default 1 Maximum Default 150 Data Matrix Code Page On Off Minimum Message Length Maximum Message Length ...

Page 111: ...ar code with the append trigger character s it buffers the number of Aztec bar codes determined by information encoded in those bar codes Once the proper number of codes is reached the data is output in the order specified in the bar codes Default On Aztec Code Page Aztec Code pages define the mapping of character codes to characters If the data received does not display with the proper characters...

Page 112: ...ters should then appear properly Chinese Sensible Han Xin Code Default All Han Xin Settings Han Xin Code On Off Han Xin Code Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 1 for additional information Minimum and Maximum lengths 1 7833 Minimum Default 1 Maximum Default 7833 Aztec Code Page On Off Minimum Message Length Maximum Messag...

Page 113: ...an be active at a time If you scan a second 2D postal code selection the first selection is overwritten Default 2D Postal Codes Off Single 2D Postal Codes 2D Postal Codes Off Australian Post On British Post On Canadian Post On Intelligent Mail Bar Code On Japanese Post On KIX Post On Planet Code On Also see Planet Code Check Digit page 6 44 Postal 4i On ...

Page 114: ... and B Fields On InfoMail On InfoMail and British Post On Intelligent Mail Bar Code and Postnet with B and B Fields On Postnet and Postal 4i On Postnet and Intelligent Mail Bar Code On Postal 4i and Intelligent Mail Bar Code On Postal 4i and Postnet with B and B Fields On Planet Code and Postnet On ...

Page 115: ...On Planet Code Postnet and Intelligent Mail Bar Code On Planet Code Postal 4i and Intelligent Mail Bar Code On Postnet Postal 4i and Intelligent Mail Bar Code On Planet Code Postal 4i and Postnet with B and B Fields On Planet Code Intelligent Mail Bar Code and Postnet with B and B Fields On Postal 4i Intelligent Mail Bar Code and Postnet with B and B Fields On ...

Page 116: ...ation is applied to customer fields in Australian 4 State symbols Bar Output lists the bar patterns in 0123 format Numeric N Table causes that field to be interpreted as numeric data using the N Table Alphanumeric C Table causes the field to be interpreted as alphanumeric data using the C Table Refer to the Australian Post Specification Tables Planet Code Postal 4i Intelligent Mail Bar Code and Po...

Page 117: ...ong Kong 2 of 5 Default All China Post Hong Kong 2 of 5 Settings China Post Hong Kong 2 of 5 On Off China Post Hong Kong 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 6 1 for addi tional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 80 Bar Output Numeric N Table Alphanumeric C Table Combination ...

Page 118: ...cription page 6 1 for addi tional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 48 Korea Post Check Digit This selection allows you to specify whether the check digit should be transmitted Default Don t Transmit Maximum Message Length On Off Minimum Message Length Maximum Message Length Transmit Check Digit Don t Transmit Check Digit ...

Page 119: ...hen the unit is power cycled Show Decoder Revision Scan the bar code below to output the decoder revision Show Scan Driver Revision Scan the bar code below to output the scan driver revision The scan driver controls image capture Show Software Revision Scan the bar code below to output the current software revision unit serial number and other product information for both the scanner and the base ...

Page 120: ... be seen in the Scan Data window The data dis played in the Scan Data window can either be saved in a file or printed Configure Configure displays the programming and configuration data of the scanner The scanner s programming and configu ration data is grouped into different categories Each category is displayed as a tree item under the Configure tree node in the application explorer When one of ...

Page 121: ...gramming options are in your scanner or you ve changed some options and want to restore the scan ner to factory default settings first scan the Remove Custom Defaults bar code then scan Activate Defaults This resets the scanner to the factory default settings The Menu Commands beginning on page 8 3 list the factory default settings for each of the commands indicated by an aster isk on the programm...

Page 122: ...7 4 ...

Page 123: ...xample the SubTag for the RS232 baud rate is BAD Data The new value for a menu setting identified by the Tag and SubTag Storage A single character that specifies the storage table to which the command is applied An exclamation point performs the command s operation on the device s volatile menu configuration table A period performs the command s operation on the device s non volatile menu configur...

Page 124: ...vice echoes back the command sequence with the status character inserted directly before each of the punctuation marks the period exclamation point comma or semicolon in the command Examples of Query Commands In the following examples a bracketed notation depicts a non displayable response Example What is the range of possible values for Codabar Coding Enable Enter cbrena Response CBRENA0 1 ACK Th...

Page 125: ...defaults it will reset the scanner to the factory default settings Any settings that have not been specified through the custom defaults will be defaulted to the factory default settings The charts on the following pages list the factory default settings for each of the commands indicated by an asterisk on the programming pages Menu Commands Selection Setting Indicates default Serial Command Indic...

Page 126: ...rf Terminal PAPWNX 2 6 Wincor Nixdorf Beetle PAPBTL 2 7 Wincor Nixdorf RS232 Mode A PAPWMA 2 7 Program Keyboard Country U S A KBDCTY0 2 8 Albania KBDCTY35 2 8 Azeri Cyrillic KBDCTY81 2 8 Azeri Latin KBDCTY80 2 8 Belarus KBDCTY82 2 8 Belgium KBDCTY1 2 8 Bosnia KBDCTY33 2 8 Brazil KBDCTY16 2 8 Brazil MS KBDCTY59 2 8 Bulgaria Cyrillic KBDCTY52 2 8 Bulgaria Latin KBDCTY53 2 9 Canada French legacy KBDC...

Page 127: ...DCTY28 2 11 Kazakh KBDCTY78 2 12 Kyrgyz Cyrillic KBDCTY79 2 12 Latin America KBDCTY14 2 12 Latvia KBDCTY42 2 12 Latvia QWERTY KBDCTY43 2 12 Lithuania KBDCTY44 2 12 Lithuania IBM KBDCTY45 2 12 Macedonia KBDCTY34 2 12 Malta KBDCTY74 2 12 Mongolian Cyrillic KBDCTY86 2 12 Norway KBDCTY9 2 12 Poland KBDCTY20 2 13 Polish 214 KBDCTY57 2 13 Polish Programmers KBDCTY58 2 13 Portugal KBDCTY13 2 13 Romania K...

Page 128: ...t all Characters to Lower Case KBDCNV1 2 16 Keyboard Style Regular KBDSTY0 2 15 Caps Lock KBDSTY1 2 15 Shift Lock KBDSTY2 2 16 Automatic Caps Lock KBDSTY6 2 16 Emulate External Keyboard KBDSTY5 2 16 Control Character Output Control Character Output Off KBDNPE0 2 17 Control Character Output On KBDNPE1 2 17 Keyboard Modifiers Control ASCII Off KBDCAS0 2 17 DOS Mode Control ASCII KBDCAS1 2 17 Windows...

Page 129: ... Direction Flow Control 232CTS2 2 21 Flow Control with Timeout 232CTS3 2 21 RS232 Timeout 232DEL 2 21 XON XOFF Off 232XON0 2 21 XON XOFF On 232XON1 2 21 ACK NAK Off 232ACK0 2 22 ACK NAK On 232ACK1 2 22 Scanner Bioptic Packet Mode Packet Mode Off 232PKT0 2 22 Packet Mode On 232PKT2 2 22 Scanner Bioptic ACK NAK Mode Bioptic ACK NAK Off 232NAK0 2 22 Bioptic ACK NAK On 232NAK1 2 22 Scanner Bioptic ACK...

Page 130: ... ms DLYGRD 3 4 Manual Trigger Mode Manual Trigger Normal PAPHHF 3 5 LED Illumination Manual Trigger Low PWRNOL7 3 5 Medium PWRNOL15 3 5 Medium High PWRNOL50 3 5 High PWRNOL150 3 5 Serial Trigger Mode Read Time Out range 0 300 000 30 000 TRGSTO 3 5 Presentation Presentation Mode PAPPST 3 6 Idle Illumination Presentation Mode Low PWRIDL7 3 6 Medium PWRIDL15 3 6 High PWRIDL50 3 6 Presentation Sensiti...

Page 131: ...R3000 3 11 Extra Long 4000ms DLY2RR4000 3 11 Character Activation Mode Off HSTCEN0 3 11 On HSTCEN1 3 11 Activation Character HSTACH 3 12 Do Not End Character Activation After Good Read HSTCGD0 3 12 End Character Activation After Good Read HSTCGD1 3 12 Character Activation Timeout Range 1 65525 5000 ms HSTCDT 3 12 Character Deactivation Mode Off HSTDEN0 3 12 On HSTDEN1 3 12 Deactivation Character H...

Page 132: ...CHR 4 3 User Specified Intercharacter Delay Delay Length 0 1000 5ms increments DLYCRX 4 4 Character to Trigger Delay DLY_XX 4 4 Interfunction Delay Range 0 1000 5ms increments DLYFNC 4 4 Intermessage Delay Range 0 1000 5ms increments DLYMSG 4 4 Data Formatter Selections Data Format Editor Default Data Format None DFMDF3 5 1 Enter Data Format DFMBK3 5 2 Clear One Data Format DFMCL3 5 2 Clear All Da...

Page 133: ...A1 6 4 Code 39 Start Stop Char Don t Transmit C39SSX0 6 4 Transmit C39SSX1 6 4 Code 39 Check Char No Check Char C39CK20 6 4 Validate But Don t Transmit C39CK21 6 5 Validate and Transmit C39CK22 6 5 Code 39 Message Length Minimum 0 48 0 C39MIN 6 5 Maximum 0 48 48 C39MAX 6 5 Code 39 Append Off C39APP0 6 5 On C39APP1 6 5 Code 32 Pharmaceutical PARAF Off C39B320 6 5 On C39B321 6 5 Code 39 Full ASCII O...

Page 134: ...On C93APP1 6 10 Off C93APP0 6 10 Code 93 Code Page Code 93 Code Page C93DCP 6 10 Straight 2 of 5 Industrial Default All Straight 2 of 5 Industrial Settings R25DFT 6 11 Off R25ENA0 6 11 On R25ENA1 6 11 Straight 2 of 5 Industrial Message Length Minimum 1 48 4 R25MIN 6 11 Maximum 1 48 48 R25MAX 6 11 Straight 2 of 5 IATA Default All Straight 2 of 5 IATA Settings A25DFT 6 12 Straight 2 of 5 IATA Off A2...

Page 135: ...A0 6 17 GS1 128 Message Length Minimum 1 80 1 GS1MIN 6 17 Maximum 0 80 80 GS1MAX 6 17 UPC A Default All UPC A Settings UPADFT 6 17 Off UPAENA0 6 18 On UPAENA1 6 18 UPC A Check Digit Off UPACKX0 6 17 On UPACKX1 6 18 UPC A Number System Off UPANSX0 6 18 On UPANSX1 6 18 UPC A 2 Digit Addenda Off UPAAD20 6 18 On UPAAD21 6 18 UPC A 5 Digit Addenda Off UPAAD50 6 18 On UPAAD51 6 18 UPC A Addenda Required...

Page 136: ...N JAN 13 Default All EAN JAN Settings E13DFT 6 23 Off E13ENA0 6 23 On E13ENA1 6 23 EAN JAN 13 Check Digit Off E13CKX0 6 23 On E13CKX1 6 23 EAN JAN 13 2 Digit Addenda 2 Digit Addenda On E13AD21 6 24 2 Digit Addenda Off E13AD20 6 24 5 Digit Addenda On E13AD51 6 24 5 Digit Addenda Off E13AD50 6 24 EAN JAN 13 Addenda Required Not Required E13ARQ0 6 24 Required E13ARQ1 6 24 EAN JAN 13 Addenda Separator...

Page 137: ...I Check Characters MSICHK6 6 28 MSI Message Length Minimum 4 48 4 MSIMIN 6 28 Maximum 4 48 48 MSIMAX 6 28 GS1 DataBar Omnidirectional Default All GS1 DataBar Omnidirectional Settings RSSDFT 6 29 Off RSSENA0 6 29 On RSSENA1 6 29 GS1 DataBar Limited Default All GS1 DataBar Limited Settings RSLDFT 6 29 Off RSLENA0 6 29 On RSLENA1 6 29 GS1 DataBar Expanded Default All GS1 DataBar Expanded Settings RSE...

Page 138: ...34 GS1 Emulation GS1 128 Emulation EANEMU1 6 34 GS1 DataBar Emulation EANEMU2 6 35 GS1 Code Expansion Off EANEMU3 6 35 EAN8 to EAN13 Conversion EANEMU4 6 35 GS1 Emulation Off EANEMU0 6 35 TCIF Linked Code 39 On T39ENA1 6 35 Off T39ENA0 6 35 QR Code Default All QR Code Settings QRCDFT 6 40 On QRCENA1 6 35 Off QRCENA0 6 35 QR Code Msg Length Minimum 1 7089 1 QRCMIN 6 36 Maximum 1 7089 7089 QRCMAX 6 ...

Page 139: ...ng 2 of 5 Default All China Post Hong Kong 2 of 5 Settings CPCDFT 6 45 Off CPCENA0 6 45 On CPCENA1 6 45 China Post Hong Kong 2 of 5 Msg Length Minimum 2 80 4 CPCMIN 6 45 Maximum 2 80 80 CPCMAX 6 46 Korea Post Default All Korea Post Settings KPCDFT 6 46 Off KPCENA0 6 46 On KPCENA1 6 46 Korea Post Msg Length Minimum 2 80 4 KPCMIN 6 46 Maximum 2 80 48 KPCMAX 6 46 Korea Post Check Digit Transmit Check...

Page 140: ...ail Bar Code On POSTAL24 6 43 Planet Postal 4i and Postnet with B and B Fields On POSTAL25 6 43 Planet Intelligent Mail Bar Code and Postnet with B and B Fields On POSTAL26 6 43 Postal 4i Intelligent Mail Bar Code and Postnet with B and B Fields On POSTAL27 6 43 Planet Postal 4i Intelligent Mail Bar Code and Postnet On POSTAL28 6 44 Planet Postal 4i Intelligent Mail Bar Code and Postnet with B and...

Page 141: ...8 19 Resetting the Factory Defaults Remove Custom Defaults DEFOVR 7 3 Activate Defaults DEFALT 7 3 Selection Setting Indicates default Serial Command Indicates a numeric entry Page ...

Page 142: ...8 20 ...

Page 143: ... Light Levels 0 to 100 000 lux 9 290 foot candles ESD 15kV Air 8kV contact Image Image Size 1280 x 800 pixels Scan Performance Pitch Skew 60 70 Motion Tolerance Presentation Mode up to 10cm per second for 13 mil UPC Symbol Contrast 35 Depth of Field Typical Performance 5 mil Code 39 58 190mm 2 3 7 5 in 13 mil UPC A 15 320mm 0 6 13 in 20 mil Code 39 28 254mm 1 1 10 in 6 7 mil PDF417 38 160mm 1 5 6 ...

Page 144: ... legacy products Use of a cable with improper pin assignments may lead to damage to the unit Use of any cables not provided by the manufacturer may result in damage not covered by your warranty USB 10 Pin Modular Plug 1 Cable shield 2 Cable select 3 Supply ground 4 5 6 7 5V power 8 9 Data 10 Data ...

Page 145: ...9 3 Required Safety Labels Part Number Serial Number Label and Revision Information location Youjie HH660 Scanner ...

Page 146: ...9 4 ...

Page 147: ...ting Cords and Connectors Inspect the interface cable and connector for wear or other signs of damage A badly worn cable or damaged connector may interfere with scanner operation Contact your distributor for information about cable replacement Cable replacement instructions are on page 10 1 Replacing Cables in Corded Scanners The standard interface cable is attached to the scanner with an 10 pin m...

Page 148: ...ving trouble reading your symbols If the scanner isn t reading symbols well check that the scanner window is clean and that the symbols Aren t smeared rough scratched or exhibiting voids Aren t coated with frost or water droplets on the surface Are enabled in the scanner or in the decoder to which the scanner connects Is the bar code displayed but not entered The bar code is displayed on the host ...

Page 149: ...abar Fm 0 1 a 61 Code 11 H3 h 68 Code 128 Cm 0 1 2 4 j 6A Code 32 Pharmaceutical PARAF X0 3C Code 39 supports Full ASCII mode Am 0 1 3 4 5 7 b 62 TCIF Linked Code 39 TLC39 L2 T 54 Code 93 and 93i Gm 0 9 A Z a m i 69 EAN Em 0 1 3 4 d 64 EAN 13 including Bookland EAN E0 d 64 EAN 13 with Add On E3 d 64 EAN 13 with Extended Coupon Code E3 d 64 EAN 8 E4 D 44 EAN 8 with Add On E3 D 44 GS1 GS1 DataBar em...

Page 150: ...Code zm 0 9 A C z 7A Chinese Sensible Code Han Xin Code X0 H 48 Codablock A O6 0 1 4 5 6 V 56 Codablock F Om 0 1 4 5 6 q 71 Code 49 Tm 0 1 2 4 l 6C Data Matrix dm 0 6 w 77 GS1 em 0 3 y 79 GS1 Composite em 0 3 y 79 GS1 DataBar Omnidirectional em 0 3 y 79 MaxiCode Um 0 3 x 78 PDF417 Lm 0 2 r 72 MicroPDF417 Lm 0 5 R 52 QR Code Qm 0 6 s 73 Micro QR Code Qm s 73 AIM Honeywell Symbology ID Possible modi...

Page 151: ...CII CTRL X Mode Control X Mode Off KBDCAS0 Windows Mode Control X Mode On KBDCAS2 DEC HEX Char CTRL X CTRL X function 0 00 NUL Reserved CTRL 1 01 SOH NP Enter CTRL A Select all 2 02 STX Caps Lock CTRL B Bold 3 03 ETX ALT Make CTRL C Copy 4 04 EOT ALT Break CTRL D Bookmark 5 05 ENQ CTRL Make CTRL E Center 6 06 ACK CTRL Break CTRL F Find 7 07 BEL Enter Ret CTRL G 8 08 BS Apple Make CTRL H History 9 ...

Page 152: ...8 72 48 H 104 68 h 41 29 73 49 I 105 69 i 42 2A 74 4A J 106 6A j 43 2B 75 4B K 107 6B k 44 2C 76 4C L 108 6C l 45 2D 77 4D M 109 6D m 46 2E 78 4E N 110 6E n 47 2F 79 4F O 111 6F o 48 30 0 80 50 P 112 70 p 49 31 1 81 51 Q 113 71 q 50 32 2 82 52 R 114 72 r 51 33 3 83 53 S 115 73 s 52 34 4 84 54 T 116 74 t 53 35 5 85 55 U 117 75 u 54 36 6 86 56 V 118 76 v 55 37 7 87 57 W 119 77 w 56 38 8 88 58 X 120 ...

Page 153: ...C 146 92 Æ F3 0x3D 147 93 ô F4 0x3E 148 94 ö F5 0x3F 149 95 ò F6 0x40 150 96 û F7 0x41 151 97 ù F8 0x42 152 98 ÿ F9 0x43 153 99 Ö F10 0x44 154 9A š Ü F11 0x57 155 9B F12 0x58 156 9C œ Numeric Keypad 0x4E 157 9D Numeric Keypad 0x4A 158 9E ž Numeric Keypad 0x37 159 9F Ÿ ƒ Caps Lock 0x3A 160 A0 á Num Lock 0x45 161 A1 í Left Alt 0x38 162 A2 ó Left Ctrl 0x1D 163 A3 ú Left Shift 0x2A 164 A4 ñ Right Shif...

Page 154: ... C8 È 201 C9 É 202 CA Ê 203 CB Ë 204 CC Ì 205 CD Í 206 CE Î 207 CF Ï 208 D0 Ð 209 D1 Ñ 210 D2 Ò 211 D3 Ó 212 D4 Ô 213 D5 Õ 214 D6 Ö 215 D7 216 D8 Ø 217 D9 Ù 218 DA Ú 219 DB Û 220 DC Ü 221 DD Ý 222 DE Þ 223 DF ß 224 E0 à α 225 E1 á ß 226 E2 â Γ 227 E3 ã π 228 E4 ä Σ 229 E5 å σ 230 E6 æ µ Extended ASCII Characters Continued DEC HEX CP 1252 ASCII Alternate Extended PS2 Scan Code ...

Page 155: ...44 F4 ô 245 F5 õ 246 F6 ö 247 F7 248 F8 ø 249 F9 ù 250 FA ú 251 FB û 252 FC ü ⁿ 253 FD ý 254 FE þ 255 FF ÿ Code Page Selection Method Country Standard Keyboard Country Honeywell Code Page Option United States standard ASCII ISO IEC 646 IRV n a 1 Automatic National Character Replacement ISO IEC 2022 n a 2 default Binary Code page n a n a 3 Default Automatic National Character replacement will selec...

Page 156: ... Hex 23 24 40 5B 5C 5D 5E 60 7B 7C 7D 7E US 0 1 CA 54 95 à â ç ê î ô é ù è û CA 18 96 à â ç ê É ô é ù è û JP 28 98 CN 92 99 GB 7 87 FR 3 83 à ç µ é ù è DE 4 84 Ä Ö Ü ä ö ü ß CH 6 86 ù à é ç ê î ô ä ö ü û SE FI 2 82 É Ä Ö Å Ü é ä ö å ü DK 8 88 Æ Ø Å æ ø å NO 9 94 Æ Ø Å æ ø å IE 73 97 Ó É Í Ú Á ó é í ú á IT 5 85 ç é ù à ò è ì PT 13 92 Ã Ç Õ ã ç õ ES 10 90 Ñ ñ ç ES 51 91 Ñ Ç ñ ç COUNTRY Country Keybo...

Page 157: ...54 59 3A 3B 3C 3E 3F 38 40 3D 5A 5F 64 5B 60 65 5C 61 66 5D 62 67 63 68 69 6A 6C 104 Key U S Style Keyboard 6E 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 4B 50 55 4C 51 56 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1E 2C 1F 20 21 22 23 24 25 26 27 28 29 2B 39 2E 2F 30 31 32 33 34 35 36 37 53 4F 54 59 3A 3B 3C 3E 3F 38 40 3D 5A 5F 64 5B 60 65 5C 61 66 5D 62 6...

Page 158: ...A 10 ...

Page 159: ...Sample Symbols UPC A 0 123456 7890 Interleaved 2 of 5 1234567890 EAN 13 9 780330 290951 Code 128 Code 128 Code 39 BC321 Codabar A13579B Code 93 123456 9 Straight 2 of 5 Industrial 123456 ...

Page 160: ...6543210 Matrix 2 of 5 GS1 DataBar 01 00123456789012 PDF417 Car Registration Data Matrix Test Symbol QR Code Numbers Aztec Package Label MaxiCode Test Message Micro PDF417 Test Message Postnet Zip Code ...

Page 161: ...4 CB 4 State Customer Bar Code 01 234 567094 987654321 01234567891 ID tag UPU 4 State J18CUSA8E6N062315014880T ...

Page 162: ...Programming Chart 0 1 2 3 4 5 6 7 8 9 ...

Page 163: ...Programming Chart Note If you make an error while scanning the letters or digits before scanning Save scan Discard scan the correct letters or digits and Save again A B C D E F Save Discard Reset ...

Page 164: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com YJ HH660 UG Rev A 1 16 ...

Reviews: