XNX Universal Transmitter
Installation and Operation
36
Single Transmitter Distances
For installations that have dedicated wiring between the
transmitter and the power supply, use the following chart. These
distances assume stranded wire is used. If multiple transmitters
are using the same power supply, make sure the power
supply wattage rating is high enough to power all transmitters
simultaneously.
Power Supply
Power Supply
OR
Figure 30. Single transmitter distances
Single Transmitter Distances
Configuration
18 AWG
[1.0 mm2]
16 AWG
[1.5 mm2]
14 AWG
[2.0 mm2]
12 AWG
[3.5 mm2]
transmitter mV or EC
with sensor
1140 feet
[347 meters]
1810 feet
[551 meters]
2890 feet
[880 meters]
4620 feet
[1408
meters]
transmitter IR with
Searchpoint Optima Plus
660 feet
[201 meters]
1060 feet
[323 meters]
1690 feet
[515 meters]
2690 feet
[820 meters]
transmitter IR with
Searchline Excel
550 feet
[168 meters]
890 feet
[270 meters]
1410 feet
[430 meters]
2260 feet
[690 meters]
Daisy-Chained Transmitter Distances
It is difficult to calculate distances for this configuration. There
are many factors to be considered: distance from control room
to first transmitter, distance between transmitters, sensor types,
etc. A few scenarios are presented here to provide a base to
work from.
Power Supply
“d”
“d”
“d”
“d”
“d”
Transmitter 1
Transmitter 2
Transmitter 3
Transmitter 4
Transmitter 5
Figure 31. Daisy-chained transmitter distances
1. Several transmitters equally spaced from themselves and
the power source.
2 Transmitters - Distance “d”
Configuration
18 AWG
[1.0 mm2]
16 AWG
[1.5 mm2]
14 AWG
[2.0 mm2]
12 AWG
[3.5 mm2]
transmitter mV or EC
with sensor
380 feet
[115 meters]
600 feet
[183 meters]
960 feet
[292 meters]
1540 feet
[469 meters]
transmitter IR with
Searchpoint Optima Plus
220 feet
[67 meters]
350 feet
[106 meters]
560 feet
[170 meters]
900 feet
[274 meters]
transmitter IR with
Searchline Excel
185 feet
[56 meters]
295 feet
[90 meters]
470 feet
[143 meters]
750 feet
[229 meters]
Summary of Contents for XNX-AM Series
Page 2: ...This page is intentionally left blank ...
Page 7: ...XNX Universal Transmitter Safety and Information 5 Safety and Information ...
Page 12: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 10 Introduction ...
Page 27: ...XNX Universal Transmitter Introduction 25 Menu Navigation ...
Page 102: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 100 Calibration ...
Page 118: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 116 Maintenance ...
Page 122: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 120 Warnings and Faults ...
Page 139: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 137 Specifications ...
Page 174: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 172 Control Drawings ...
Page 177: ...XNX Universal Transmitter Control Drawings 175 ...
Page 179: ...XNX Universal Transmitter Control Drawings 177 Remote Sensor Mount ...
Page 180: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 178 HART Protocol ...
Page 193: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 191 Modbus Protocol ...
Page 200: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 198 Warranty ...
Page 202: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 200 Index ...