XNX Universal Transmitter
Specifications
156
Certifications by Part Number Series
Contact Honeywell Analytics for information about XNX
®
Universal Transmitter approvals not shown in this section.
XNX Certifications XNX-UT Series
XNX Part Number Series
XNX
Transmitter IR
Personality
XNX Transmitter mV Personality
XNX Transmitter EC
Personality
Options
XNX-UTSI-*****
XNX-UTAI-*****
XNX-UTSV-***** / XNX-UTAV-*****
XNX-UTSE-***** /
XNX-UTAE-*****
W
ith Generic 20 mA
Input
W
ith Optima Plus
W
ith Searchline Excel
MPD-UTCB1 (Cat Bead)
MPD-UTIV1 (IR Methane)
MPD-UTIF1 (IR Flam)
MPD-UTIC1 (IR CO
2
)
with 705
with Sensepoint
with Sensepoint PPM
with Sensepoint HT
W
ith XNXXSO1FM O
2
Cartrdige
W
ith XNXXSH1FM H
2
S Cartridge
W
ith XNXXSC1FM CO Cartridge
SO
2
, NH
3
, Cl
2
, ClO
2
, NO, NO
2
, H
2
PPM, HCL, HF
, PH
3
HCN, F
2
, O
3
, EtO
Modbus
®
Relays
Local HART
®
FOUNDA
TION™ Fieldbus
UL Listed
For Hazardous Locations
UL 1203
T
T
T
T
T
T
T
T
N/A N/A N/A
T
T
T
T
T
T
T
T
T
UL 913-7th Edition
N/A
N/A
N/A N/A N/A N/A N/A N/A N/A N/A N/A
T
T
T
T
T
N/A N/A
T N/A
ISA 60079-29-1
N/A
T
N/A
T
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
CSA
Hazardous Location
CAN/CSA C22.2 No. 30 M-1986
T
T
T
T
N/A N/A
T
T
N/A N/A N/A
T
T
T
T
T
T
T
T N/A
CAN/CSA C22.2 No. 157-92
(Applies to Local HART Option and/or
EC Adaptors)
N/A
N/A
N/A N/A N/A N/A N/A N/A N/A N/A N/A
T
T
T
T
T
N/A N/A
T N/A
Performance
CSA C22.2 No. 152
N/A
T
N/A
T
N/A N/A N/A
T
N/A N/A N/A N/A N/A N/A N/A N/A
T
T
T
T
FM Listed
US Toxic Performance
Standard referenced in notes 1, 2, 3
N/A
N/A
N/A N/A N/A N/A
3
N/A N/A N/A N/A
1
2
3
N/A N/A
T
T
T
T
Flammable Performance
FM 6310 / 6320
N/A
T
N/A
T
N/A N/A N/A
T
N/A N/A N/A N/A N/A N/A N/A N/A
T
T
T
T
FM 6325
N/A
N/A
T
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
T
T
T
T
Toxic Gas Detector
FM 6340
N/A
N/A
N/A N/A N/A N/A
T
N/A N/A N/A N/A N/A N/A N/A N/A N/A
T
T
T
T
T = 3/4 NPT threaded Transmitters & Adapters
N/A = Not Applicable
1. ANSI/ISA 92.04.01, Part 1 2007
2. ISA 92.0.01, Part 3 1998
3. FM 6340
Summary of Contents for XNX-AM Series
Page 2: ...This page is intentionally left blank ...
Page 7: ...XNX Universal Transmitter Safety and Information 5 Safety and Information ...
Page 12: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 10 Introduction ...
Page 27: ...XNX Universal Transmitter Introduction 25 Menu Navigation ...
Page 102: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 100 Calibration ...
Page 118: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 116 Maintenance ...
Page 122: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 120 Warnings and Faults ...
Page 139: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 137 Specifications ...
Page 174: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 172 Control Drawings ...
Page 177: ...XNX Universal Transmitter Control Drawings 175 ...
Page 179: ...XNX Universal Transmitter Control Drawings 177 Remote Sensor Mount ...
Page 180: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 178 HART Protocol ...
Page 193: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 191 Modbus Protocol ...
Page 200: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 198 Warranty ...
Page 202: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 200 Index ...