XNX Universal Transmitter
Introduction
13
Patents
Patents Applicable to the XNX Universal Transmitter
Patent
Number
Description
Application
6,123,818
Reflex patent
Implemented in XNX
6,251,232
Reflex patent
Implemented in XNX
6,351,982
Flammable sensor housing
XNX accepts this sensor
6,395,230
Pellistor
Sensor used in XNX
7,225,661
Gas calibration adapter
Applicable to XNX
7,716,962
Method of gas calibration
Used to calibrate XNX ECC cartridges
Glossary
Term
Description
bump test
a brief exposure to a gas to verify that a detector is working;
also known as a functional test
ferrite bead
a device that suppresses noise in a circuit
FOUNDATION Fieldbus
an open architecture, digital, serial communication system
administered by the Fieldbus Foundation
HART Protocol
Highway Addressable Remote Transducer Protocol; a bi-
directional analog communication system developed by the
HART Communication Foundation
intrinsic safety
design parameters for the safe operation of electrical equip-
ment in hazardous environments; commonly abbreviated IS
IP rating
Ingress Protection; a system for describing a device’s protec-
tion against dry materials and liquids (e.g., IP66/67)
latching alarm
an alarm that, once activated, must be manually reset
magnetic wand
a small device used to change the transmitter’s settings
Modbus
a digital communications protocol based on RS-485 topology
non-latching alarm
an alarm that automatically resets when the cause of the
alarm is removed
pellistor/bead
an electronic device used to detect combustible gases
personality board
a component of the transmitter that allows its operation to
focus on different sensing technologies
POD
Personality, Options, and Display; the group of components
including an XNX transmitter’s personality board, display, com-
munication board, etc.
span calibration
adjustment of a detector so that its scale corresponds to a gas
concentration range from 0% to 100%
sticky gases
gases that tend to coat the surfaces they contact
toxic gases
gases that are poisonous to humans (refer to the gas’s Safety
Data Sheet for details)
zero calibration
adjustment of a detector so that its zero reading corresponds
to a test gas concentration of 0%
Summary of Contents for XNX-AM Series
Page 2: ...This page is intentionally left blank ...
Page 7: ...XNX Universal Transmitter Safety and Information 5 Safety and Information ...
Page 12: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 10 Introduction ...
Page 27: ...XNX Universal Transmitter Introduction 25 Menu Navigation ...
Page 102: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 100 Calibration ...
Page 118: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 116 Maintenance ...
Page 122: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 120 Warnings and Faults ...
Page 139: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 137 Specifications ...
Page 174: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 172 Control Drawings ...
Page 177: ...XNX Universal Transmitter Control Drawings 175 ...
Page 179: ...XNX Universal Transmitter Control Drawings 177 Remote Sensor Mount ...
Page 180: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 178 HART Protocol ...
Page 193: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 191 Modbus Protocol ...
Page 200: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 198 Warranty ...
Page 202: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 200 Index ...