background image

9 - 1

9

Interface Keys

Keyboard Function Relationships

The following Keyboard Function Code, Hex/ASCII Value, and Full ASCII “CTRL”+  relationships apply to all terminals that can 
be used with the scanner.  Refer to 

page 2-16

 enable C X (C ASCII) Mode.

The last five characters in the Full ASCII “CTRL”+ column  ( [ \ ] 6 - ), apply to US only.  The following chart indicates the equiva-
lents of these five characters for different countries.

Function Code

HEX/ASCII Value

Full ASCII (CTRL + X Mode)

NUL

00

@

SOH

01

A

STX

02

B

ETX

03

C

EOT

04

D

ENQ

05

E

ACK

06

F

BEL

07

G

BS

08

H

HT

09

I

LF

0A

J

VT

0B

K

FF

0C

L

CR

0D

M

SO

0E

N

SI

0F

O

DLE

10

P

DC1

11

Q

DC2

12

R

DC3

13

S

DC4

14

T

NAK

15

U

SYN

16

V

ETB

17

W

CAN

18

X

EM

19

Y

SUB

1A

Z

ESC

1B

[

FS

1C

\

GS

1D

]

RS

1E

^

US

1F

_

Country

Codes

United States

[

\

]

6

-

Belgium

[

<

]

6

-

Scandinavia

8

<

9

6

-

France

^

8

$

6

=

Germany

Ã

+

6

-

Italy

\

+

6

-

Switzerland

<

. .

6

-

United Kingdom

[

¢

]

6

-

Summary of Contents for Vuquest 3330g

Page 1: ...Vuquest 3330g Area Imaging Scanner User s Guide ...

Page 2: ...lity for the selection and use of software and or hardware to achieve intended results This document contains proprietary information that is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated into another language without the prior written consent of HII Copyright 2015 Honeywell International Inc All rights reserved Web Address www ...

Page 3: ...2 1 Programming the Interface Plug and Play 2 1 Keyboard Wedge 2 1 Laptop Direct Connect 2 1 RS232 Serial Port 2 1 USB IBM SurePos 2 2 USB PC or Macintosh Keyboard 2 2 USB HID 2 2 USB Serial 2 3 Remote MasterMind for USB 2 3 Verifone Ruby Terminal Default Settings 2 4 Gilbarco Terminal Default Settings 2 4 Honeywell Bioptic Aux Port Configuration 2 4 Datalogic Magellan Aux Port Configuration 2 5 N...

Page 4: ...ror 3 3 Beeper Duration Good Read 3 3 LED Good Read 3 3 Number of Beeps Good Read 3 4 Number of Beeps Error 3 4 Good Read Delay 3 4 User Specified Good Read Delay 3 4 Manual Trigger Modes 3 5 LED Illumination Manual Trigger 3 5 Serial Trigger Mode 3 5 Read Time Out 3 5 Presentation Mode 3 6 LED Illumination Presentation Mode 3 6 Presentation LED Behavior after Decode 3 6 Presentation Sensitivity 3...

Page 5: ...re Output Sequence 3 19 Multiple Symbols 3 19 No Read 3 19 Video Reverse 3 20 Working Orientation 3 21 Chapter 4 Data Editing Prefix Suffix Overview 4 1 To Add a Prefix or Suffix 4 1 Example Add a Tab Suffix to All Symbologies 4 2 To Clear One or All Prefixes or Suffixes 4 2 To Add a Carriage Return Suffix to All Symbologies 4 2 Prefix Selections 4 2 Suffix Selections 4 2 Function Code Transmit 4 ...

Page 6: ...External Illumination Parameters 6 3 External Illumination Schematic 6 4 Chapter 7 Symbologies All Symbologies 7 1 Message Length Description 7 1 Codabar 7 2 Codabar Concatenation 7 3 Code 39 7 4 Code 32 Pharmaceutical PARAF 7 5 Full ASCII 7 6 Code 39 Code Page 7 6 Interleaved 2 of 5 7 7 NEC 2 of 5 7 8 Code 93 7 9 Code 93 Code Page 7 10 Straight 2 of 5 Industrial three bar start stop 7 11 Straight...

Page 7: ...Page 7 39 Data Matrix 7 40 Data Matrix Code Page 7 40 MaxiCode 7 41 Aztec Code 7 42 Aztec Code Page 7 42 Chinese Sensible Han Xin Code 7 43 Postal Codes 2D 7 44 Single 2D Postal Codes 7 44 Combination 2D Postal Codes 7 45 Postal Codes Linear 7 48 China Post Hong Kong 2 of 5 7 48 Korea Post 7 49 Chapter 8 Imaging Commands Single Use Basis 8 1 Command Syntax 8 1 Image Snap IMGSNP 8 1 IMGSNP Modifier...

Page 8: ...1 1 Menu Command Syntax 11 1 Query Commands 11 1 Responses 11 2 Trigger Commands 11 3 Resetting the Custom Defaults 11 3 Menu Commands 11 4 Chapter 12 Product Specifications 3330 Scanner Product Specifications 12 1 Depth of Field 12 2 Typical Performance 12 2 Guaranteed Performance 12 2 Mounting General Guidelines 12 3 Standard Cable Pinouts 12 4 Keyboard Wedge 12 4 Serial Output 12 5 USB 12 5 Cha...

Page 9: ...arts A 1 Linear Symbologies A 1 2D Symbologies A 3 Postal Symbologies A 3 ASCII Conversion Chart Code Page 1252 A 3 Lower ASCII Reference Table A 4 ISO 2022 ISO 646 Character Replacements A 8 Unicode Key Maps A 10 Sample Symbols Programming Chart ...

Page 10: ...viii ...

Page 11: ...ain warranty or non warranty service please visit www honeywellaidc com and select Support Contact Service and Repair to see your region s instructions on how to obtain a Return Material Authorization number RMA You should do this prior to returning the product Limited Warranty Refer to www honeywellaidc com warranty_information for your product s warranty information Send Feedback Your feedback i...

Page 12: ...x ...

Page 13: ...rton match your order Save the shipping container for later storage or shipping Connecting the Device Connecting with USB A scanner can be connected to the USB port of a computer 1 Connect the appropriate interface cable to the device first then to the computer 2 The scanner beeps 3 Verify the scanner operation by scanning a bar code from the Sample Symbols in the back of this manual The unit defa...

Page 14: ...l computer 2 Connect the appropriate interface cable to the scanner Note For the scanner to work properly you must have the correct cable for your type of terminal computer 3 Plug the serial connector into the serial port on your computer Tighten the two screws to secure the connector to the port 4 Once the scanner has been fully connected power up the computer This interface programs 115 200 baud...

Page 15: ... may be necessary to tilt the code up 15 to 18 to prevent unwanted reflection Menu Bar Code Security Settings Honeywell scanners are programmed by scanning menu bar codes or by sending serial commands to the scanner If you want to restrict the ability to scan menu codes you can use the Menu Bar Code Security settings Please contact the nearest techni cal support office see Technical Assistance on ...

Page 16: ... Custom Defaults The rest of the custom defaults will remain but the beeper volume setting will be updated Resetting the Custom Defaults If you want the custom default settings restored to your scanner scan the Activate Custom Defaults bar code below This is the recommended default bar code for most users It resets the scanner to the custom default settings If there are no custom defaults it will ...

Page 17: ...e return CR suffix Laptop Direct Connect For most laptops scanning the Laptop Direct Connect bar code allows operation of the scanner in parallel with the inte gral keyboard The following Laptop Direct Connect bar code also programs a carriage return CR suffix and turns on Emulate External Keyboard page 2 15 RS232 Serial Port The RS232 Interface bar code is used when connecting to the serial port ...

Page 18: ...d Scan one of the following codes to program the scanner for USB PC Keyboard or USB Macintosh Keyboard Scanning these codes also adds a CR and LF USB HID Scan the following code to program the scanner for USB HID bar code scanners Symbology Suffix Symbology Suffix EAN 8 0C Code 39 00 0A 0B EAN 13 16 Interleaved 2 of 5 00 0D 0B UPC A 0D Code 128 00 18 0B UPC E 0A Code 39 00 0A 0B USB IBM SurePos US...

Page 19: ... scanner as a USB CDC class device and automatically use a class driver Note No extra configuration e g baud rate is necessary CTS RTS Emulation ACK NAK Mode Remote MasterMind for USB When using a USB interface you may wish to configure your scanner to communicate with Remote MasterMind Scanner Management Software ReM Scan the ReM On bar code to communicate with ReM To disable this capability scan...

Page 20: ...ata bits even parity 2 stop bits It also adds a carriage return CR suffix and programs the following prefixes for each symbology Note If you are having unexpected results with this programming code scan the Activate Defaults bar code on page 1 4 first then scan the programming code above Honeywell Bioptic Aux Port Configuration Scan the following Plug and Play code to program the scanner for a Hon...

Page 21: ... prefixes are programmed for each symbology Note If you are having unexpected results with this programming code scan the Activate Defaults bar code on page 1 4 first then scan the programming code above Wincor Nixdorf Terminal Default Settings Scan the following Plug and Play code to program the scanner for a Wincor Nixdorf terminal This bar code sets the baud rate to 9600 bps and the data format...

Page 22: ...rd To change this layout refer to the chart below for your keyboard country Scan the appropriate bar code below to change the layout By default national character replacements are used for the following characters See ISO 2022 ISO 646 Character Replacements on page A 8 to view the character replacements for each country Symbology Prefix Symbology Prefix Aztec Code V Interleaved 2 of 5 I Codabar N ...

Page 23: ...2 7 Keyboard Countries Continued Belgium Bosnia Brazil Brazil MS Bulgaria Cyrillic Bulgaria Latin Canada French legacy Canada French Canada Multilingual Croatia Czech ...

Page 24: ...2 8 Keyboard Countries Continued Czech Programmers Czech QWERTY Czech QWERTZ Denmark Dutch Netherlands Estonia Faroese Finland France Gaelic Germany ...

Page 25: ...2 9 Keyboard Countries Continued Greek Greek 220 Latin Greek 220 Greek 319 Latin Greek 319 Greek Latin Greek MS Greek Polytonic Hebrew Hungarian 101 key Hungary ...

Page 26: ...2 10 Keyboard Countries Continued Iceland Irish Italian 142 Italy Japan ASCII Kazakh Kyrgyz Cyrillic Latin America Latvia Latvia QWERTY Lithuania ...

Page 27: ...2 11 Keyboard Countries Continued Lithuania IBM Macedonia Malta Mongolian Cyrillic Norway Poland Polish 214 Polish Programmers Portugal Romania Russia ...

Page 28: ...2 12 Keyboard Countries Continued Russian MS Russian Typewriter SCS Serbia Cyrillic Serbia Latin Slovakia Slovakia QWERTY Slovakia QWERTZ Slovenia Spain Spanish variation ...

Page 29: ...2 13 Keyboard Countries Continued Sweden Switzerland French Switzerland German Tatar Turkey F Turkey Q Ukrainian United Kingdom United States Dvorak United States Dvorak left United Stated Dvorak right ...

Page 30: ... Lock is used if you change the Caps Lock key on and off The software tracks and reflects if you have Caps Lock on or off This selection can only be used with systems that have an LED that notes the Caps Lock status AT keyboards Autocaps via NumLock bar code should be scanned in countries e g Germany France where the Caps Lock key cannot be used to toggle Caps Lock The NumLock option works similar...

Page 31: ...interface is a keyboard wedge first scan the menu code for Automatic Caps Lock page 2 14 Otherwise your output may not be as expected Default Keyboard Conversion Off Control Character Output This selection sends a text string instead of a control character For example when the control character for a carriage return is expected the output would display CR instead of the ASCII code of 0D Refer to A...

Page 32: ...ionships page 9 1 for CTRL X Values Windows Mode Prefix Suffix Off The scanner sends key combinations for ASCII control characters for values 00 1F but it does not translate any prefix or suffix information Default Control X Mode Off Turbo Mode The scanner sends characters to a terminal faster If the terminal drops characters do not use Turbo Mode Default Off Numeric Keypad Mode Sends numeric char...

Page 33: ...tomatic Direct Connect Mode This selection can be used if you have an IBM AT style terminal and the system is dropping characters Default Off Automatic Direct Connect Mode On Automatic Direct Connect Mode Off ...

Page 34: ... Baud Rate Baud Rate sends the data from the scanner to the terminal at the specified rate The host terminal must be set for the same baud rate as the scanner Default 115 200 300 600 1200 2400 4800 9600 19200 38400 57600 115 200 ...

Page 35: ...If an application requires only ASCII Hex characters 0 through 7F decimal text digits and punctuation select 7 data bits For applications that require use of the full ASCII set select 8 data bits per character Default 8 Stop Bits sets the stop bits at 1 or 2 Default 1 300 600 1200 2400 4800 9600 19200 38400 57 600 115 200 ...

Page 36: ...dity Default None 7 Data 1 Stop Parity Even 7 Data 1 Stop Parity None 7 Data 1 Stop Parity Odd 7 Data 2 Stop Parity Even 7 Data 2 Stop Parity None 7 Data 2 Stop Parity Odd 8 Data 1 Stop Parity Even 8 Data 1 Stop Parity None 8 Data 1 Stop Parity Odd 8 Data 1 Stop Parity Mark ...

Page 37: ...out The scanner asserts RTS when it has data to send and will wait indefinitely for CTS to be asserted by the host Two Direction Flow Control The scanner asserts RTS when it is OK for the host to transmit The host asserts CTS when it is OK for the device to transmit Flow Control with Timeout The scanner asserts RTS when it has data to send and waits for a delay see RS232 Timeout on page 2 21 for C...

Page 38: ...s received the last set of bar code data is retransmitted and the scanner waits for ACK NAK again Turn on the ACK NAK protocol by scanning the ACK NAK On bar code below To turn off the protocol scan ACK NAK Off Default ACK NAK Off Scanner to Bioptic Communication The following settings are used to set up communication between Honeywell scanners and bioptic scanners Note The scanner s baud rate mus...

Page 39: ...ow long the scanner will wait for a response Default Bioptic ACK NAK Off Scanner Bioptic ACK NAK Timeout This allows you to set the length in milliseconds for a timeout for a bioptic scanner s ACK NAK response Scan the bar code below then set the timeout from 1 30 000 milliseconds by scanning digits from the inside back cover then scanning Save Default 5100 Bioptic ACK NAK Off Bioptic ACK NAK On A...

Page 40: ...2 24 ...

Page 41: ...n BEL On bar code below the scanner will beep every time a BEL character is received from the host Default Beep on BEL Off Trigger Click To hear an audible click every time the scanner button is pushed scan the Trigger Click On bar code below Scan the Trigger Click Off code if you don t wish to hear the click This feature has no effect on serial or automatic triggering Default Trigger Click Off Po...

Page 42: ...rror and menu beeps are still audible Default Beeper Good Read On Beeper Volume Good Read The beeper volume codes modify the volume of the beep the scanner emits on a good read Default High Beeper Pitch Good Read The beeper pitch codes modify the pitch frequency of the beep the scanner emits on a good read Default Medium Beeper Good Read Off Beeper Good Read On Low Medium High Off Low 1600 Hz Medi...

Page 43: ...z Beeper Duration Good Read The beeper duration codes modify the length of the beep the scanner emits on a good read Default Normal LED Good Read The LED indicator can be programmed On or Off in response to a good read Default On High 4200 Hz Razz 250 Hz Medium 3250 Hz High 4200 Hz Normal Beep Short Beep Short Beep LED Good Read On LED Good Read Off ...

Page 44: ...rogrammed from 1 9 For example if you program this option to have five error beeps there will be five error beeps and five LED flashes in response to an error To change the number of error beeps scan the bar code below and then scan a digit 1 9 bar code and the Save bar code on the Programming Chart inside the back cover of this manual Default 1 Good Read Delay This sets the minimum amount of time...

Page 45: ... the brighter the LEDs need to be so the scanner can see the bar codes Serial Trigger Mode You can activate the scanner either by pushing the button or using a serial trigger command see Trigger Commands on page 11 3 When in serial mode the scanner scans until a bar code has been read or until the deactivate command is sent The scanner can also be set to turn itself off after a specified time has ...

Page 46: ...or the scanner when it is in Presentation Mode If the scanner is triggered manually the LED illumination will switch to the setting for a manual trigger See LED Illumination Manual Trigger on page 3 5 Default High Note The LEDs are like a flash on a camera The lower the ambient light in the room the brighter the LEDs need to be so the scanner can see the bar codes Note LED Illumination Presentatio...

Page 47: ...ntering page 3 14 If a bar code is not touched by a predefined window it will not be decoded or output by the scanner If Presentation Center ing is turned on by scanning Presentation Centering On the scanner only reads codes that pass through the centering window you specify using the Top of Presentation Centering Window Bottom of Presentation Centering Window Left and Right of Presentation Center...

Page 48: ... On the button is used to allow decoded data to be transmitted to the host system The scanner remains on scanning and decoding bar codes but the bar code data is not transmitted until the button is pushed When CodeGate is Off bar code data is transmitted when it is decoded Default CodeGate Off Out of Stand Presentation Centering On Presentation Centering Off Top of Presentation Centering Window Bo...

Page 49: ...e speed of scanning printed bar codes may be slightly lower when this mode is enabled You can enable Mobile Phone Read ing for either a hand held device or for a hands free presentation application Note To turn off Mobile Phone Read Mode scan a Manual or Serial Trigger Mode bar code see page 3 5 Hands Free Time Out The Presentation Mode is referred to as hands free mode If the scanner s button is ...

Page 50: ... scanning Scan the following bar code then use the Programming Chart to read the alphanumeric combination that represents that ASCII character Scan Save to finish Character Activation Laser Timeout You can set a timeout for the length of time the laser remains on and attempting to decode bar codes when using Character Activation Mode Set the length in milliseconds for a timeout by scanning the fol...

Page 51: ...de the back cover of this manual then scanning Save Default 30 000 ms Deactivation Character This sets the character used to terminate scanning when using Character Deactivation Mode On the ASCII Conversion Chart Code Page 1252 page A 3 find the hex value that represents the character you want to use to terminate scanning Scan the following bar code then use the Programming Chart to read the alpha...

Page 52: ...es 2D bar codes can take longer to read than other bar codes If you wish to set a separate Reread Delay for 2D bar codes scan one of the programming codes that follows 2D Reread Delay Off indicates that the time set for Reread Delay is used for both 1D and 2D bar codes Default 2D Reread Delay Off Medium 750 ms Long 1000 ms Extra Long 2000 ms User Specified Reread Delay 2D Reread Delay Off Short 10...

Page 53: ...n the button is pushed and when the picture is taken During the delay time the aiming light will appear but the LEDs won t turn on until the delay time is over Default Off User Specified Aimer Delay If you want to set your own length for the duration of the delay scan the bar code below then set the time out by scanning digits 0 4 000 ms from the Programming Chart inside the back cover of this man...

Page 54: ...r only reads codes that pass through the centering window you specify using the Top of Centering Win dow Bottom of Centering Window Left and Right of Centering Window selections In the example below the white box is the centering window The centering window has been set to 20 left 30 right 8 top and 25 bottom Since Bar Code 1 passes through the centering window it will be read Bar Code 2 does not ...

Page 55: ...en a low priority symbology is presented the scanner ignores it for a set period of time see Preferred Symbology Time out on page 3 16 while it searches for the high priority symbology If a high priority symbology is located during this period then that data is read imme diately If the time out period expires before a high priority symbology is read the scanner will read any bar code in its view l...

Page 56: ...out period This is the period of time the scanner will search for a high priority bar code after a low priority bar code has been encountered Scan the bar code below then set the delay from 1 3 000 milliseconds by scanning digits from the inside back cover then scanning Save Default 500 ms Preferred Symbology Default Scan the bar code below to set all Preferred Symbology entries to their default v...

Page 57: ...eric combination that represents the ASCII characters 99 is the Universal number indicating all characters 5 End Output Sequence Editor Scan F F to enter an Output Sequence for an additional symbology or Save to save your entries Other Programming Selections Discard This exits without saving any Output Sequence changes Output Sequence Example In this example you are scanning Code 93 Code 128 and C...

Page 58: ...39 41h A FF termination string for first code 6A code identifier for Code 128 0013 B Code 128 sample length 12 plus CR suffix 1 13 42 start character match for Code 128 42h B FF termination string for second code 69 code identifier for Code 93 0012 C Code 93 sample length 11 plus CR suffix 1 12 43 start character match for Code 93 43h C FF termination string for third code Output Sequence Editor P...

Page 59: ...bols When this programming selection is turned On it allows you to read multiple symbols with a single push of the scanner s button If you push and hold the button aiming the scanner at a series of symbols it reads unique symbols once beeping if turned on for each read The scanner attempts to find and decode new symbols as long as the button is pushed When this programming selection is turned Off ...

Page 60: ...de below is an example of this type of bar code Scan Video Reverse Only to read only inverted bar codes Scan Video Reverse and Stan dard Bar Codes to read both types of codes Note After scanning Video Reverse Only menu bar codes cannot be read You must scan Video Reverse Off or Video Reverse and Standard Bar Codes in order to read menu bar codes Note Images downloaded from the unit are not reverse...

Page 61: ...ideways or upside down Use the working orientation settings if your direction sensitive codes will not usually be presented upright to the scanner Default Upright Upright Vertical Top to Bottom Rotate CW 90 Upside Down Vertical Bottom to Top Rotate CCW 90 Upright Vertical Bottom to Top Upside Down Vertical Top to Bottom ...

Page 62: ...3 22 ...

Page 63: ...ymbologies the specific symbology ID value counts as an added prefix or suffix character The maximum size of a prefix or suffix configuration is 200 characters which includes header information To Add a Prefix or Suffix Step 1 Scan the Add Prefix or Add Suffix symbol page 4 2 Step 2 Determine the 2 digit Hex value from the Symbology Chart included in the Symbology Charts beginning on page A 1 for ...

Page 64: ...aracter from a symbology When you Clear All Prefixes Suffixes all the prefixes or suffixes for a symbology are deleted Step 1 Scan the Clear One Prefix or Clear One Suffix symbol Step 2 Determine the 2 digit Hex value from the Symbology Chart included in the Symbology Charts beginning on page A 1 for the symbology from which you want to clear the prefix or suffix Step 3 Scan the 2 digit hex value ...

Page 65: ... delays slow the transmission of data increasing data integrity Intercharacter Delay An intercharacter delay of up to 5000 milliseconds in 5ms increments may be placed between the transmission of each character of scanned data Scan the Intercharacter Delay bar code below then scan the number of 5ms delays and the Save bar code using the Programming Chart inside the back cover of this manual To rem...

Page 66: ...ssage string Scan the Interfunction Delay bar code below then scan the number of 5ms delays and the Save bar code using the Programming Chart inside the back cover of this manual To remove this delay scan the Interfunction Delay bar code then set the number of delays to 0 Scan the Save bar code using the Programming Chart inside the back cover of this manual Intermessage Delay An intermessage dela...

Page 67: ...on the bar code data If there is no other data format the raw data is output If you have changed data format settings and wish to clear all formats and return to the factory defaults scan the Default Data Format code below Add a Data Format Step 1 Scan the Enter Data Format symbol page 5 2 Step 2 Select Primary Alternate Format Determine if this will be your primary data format or one of 3 alterna...

Page 68: ...g Selections Clear One Data Format This deletes one data format for one symbology If you are clearing the primary format scan 0 from the Programming Chart inside the back cover of this manual If you are clearing an alternate format scan 1 2 or 3 depending on the format you are clearing Scan the Terminal Type and Code I D see Symbology Charts on page A 1 and the bar code data length for the specifi...

Page 69: ...ue 00 99 for the number of characters and xx stands for the insert character s hex value for its ASCII code Refer to the ASCII Conversion Chart Code Page 1252 beginning on page A 3 for decimal hex and character codes F2 Example Send a number of characters Send the first 10 characters from the bar code above followed by a carriage return Command string F2100D F2 is the Send a number of characters c...

Page 70: ...h string s s The cursor is moved forward to the beginning of the s s string Syntax B9nnnns s where nnnn stands for the length of the string and s s stands for the string to be matched The string is made up of hex values for the characters in the string Refer to the ASCII Conversion Chart Code Page 1252 beginning on page A 3 for decimal hex and character codes B9 Example Send all characters up to a...

Page 71: ... Using the bar code above send all characters up to but not including AB Insert 2 asterisks at that point and send the rest of the data with a carriage return after Command string B900024142BA00022A2AF10D B9 is the Send all characters up to a string command 0002 is the length of the string 2 characters 41 is the hex value for A 42 is the hex value for B BA is the Insert a string command 0002 is th...

Page 72: ...functions Syntax B5xxssnn where xx is the number of keys pressed without key modifiers ss is the key modifier from the table below and nn is the key number from the Unicode Key Maps page A 10 For example B501021F inserts an A on a 104 key U S style keyboard B5 the command 01 number of keys pressed without the key modifier 02 is the key modifier for Shift Right and 1F is the a key If a lower case a...

Page 73: ...ers followed by a carriage return Using the bar code above Command string FE31F7F2060D FE is the Compare characters command 31 is the hex value for 1 F7 is the Move the cursor to the beginning command F2 is the Send a number of characters command 06 is the number of characters to send 0D is the hex value for a CR The data is output as 123456 CR Move the cursor to the end EA Move the cursor to the ...

Page 74: ...e hex value for F 47 is the hex value for G 48 is the hex value for H F1 is the Send all characters command 0D is the hex value for a CR The data is output as FGHIJ CR Search backward for a string B1 Search backward for s string from the current cursor position leaving cursor pointing to s string Syntax B1nnnnS where nnnn is the string length up to 9999 and S consists of the ASCII hex value of eac...

Page 75: ...hat has spaces in the data You may want to remove the spaces before sending the data Using the bar code above Command string FB0120F10D FB is the Suppress characters command 01 is the number of character types to be suppressed 20 is the hex value for a space F1 is the Send all characters command 0D is the hex value for a CR The data is output as 34567890 CR Stop suppressing characters FC Disables ...

Page 76: ...re the string at the current cursor position with the 4 character string Test Refer to the ASCII Conversion Chart Code Page 1252 beginning on page A 3 for decimal hex and character codes Check for a number EC Check to make sure there is an ASCII number at the current cursor position The format is aborted if the character is not numeric EC Example Only output the data if the bar code begins with a ...

Page 77: ...its an error tone If Data format Non Match Error Tone is Off the code is disabled for reading and no tone is sounded Data Formatter When Data Formatter is turned Off the bar code data is output to the host as read including prefixes and suffixes You may wish to require the data to conform to a data format you have created and saved The following settings can be applied to your data format Data For...

Page 78: ... to hear the error tone when a non matching bar code is found scan the Data Format Non Match Error Tone On bar code Default Data Format Non Match Error Tone On Primary Alternate Data Formats You can save up to four data formats and switch between these formats Your primary data format is saved under 0 Your other three formats are saved under 1 2 and 3 To set your device to use one of these formats...

Page 79: ...example you may have set your device to the data format you saved as Data Format 3 You can switch to Data Format 1 for a single button push by scanning the Single Scan Data Format 1 bar code below The next bar code that is scanned uses Data Format 1 then reverts back to Data Format 3 Data Format 1 Data Format 2 Data Format 3 Single Scan Primary Data Format Single Scan Data Format 1 Single Scan Dat...

Page 80: ...5 14 ...

Page 81: ...ction from the third party device to trigger the scanner If you want to use the third party device object detection scan the External Trigger Control On bar code If you want to use the 3330 scan ner object detection scan the External Trigger Control Off bar code Default External Trigger Control Off External Trigger Polarity External Trigger Polarity has two states High and Low A digital high polar...

Page 82: ...a Connector Pin 6 Customer Device Power Link Not on all cables 3 3V to 5 0V Controller Standard Trigger Input Connection Fairchild NC7SZ125L6X Tri State Buffer CMOS Input Level 10K Resistor 1K Resistor 3 3V Scanner Scanner Controller Please see External Trigger Parameters for voltage levels Pin 14 3310 Scanner Host Register Data Connector Pin 6 Customer Device Power Link Not on all cables Customer...

Page 83: ...it does not exceed the current on the next line of this table while operating Maximum current driven into pin from external source High Value 5mA Maximum current limited by series resistor dissipation Parameter Values Output Low Voltage Iout 500uA High Value 0 6 Volts Internal one hundred ohm series resistor drop included Output Low Voltage Iout 1mA High Value 0 7 Volts Output Low Voltage Iout 4mA...

Page 84: ...tate buffer or equivalent 10K Resistor 100 Ohm 0603 Resistor 4 9V to 5 2V Scanner Controller Pin 15 3310 Scanner Pin 6 Customer Device Power Link Not on all cables AC Adapter Customer Ground 5 2V Scanner Power 5 2V Scanner Cable with External Trigger and Lamp Signals Yellow Wire Pin 11 To Customer PC Register data connector Black Wire Lamp Driver Switch Customer Ground Please see External Illumina...

Page 85: ...same value for mini mum and maximum length to force the scanner to read fixed length bar code data This helps reduce the chances of a misread EXAMPLE Decode only those bar codes with a count of 9 20 characters Min length 09Max length 20 All Symbologies Interleaved 2 of 5 Aztec Code Korea Post China Post Hong Kong 2 of 5 Matrix 2 of 5 Chinese Sensible Han Xin Code MaxiCode Codabar MicroPDF417 Codab...

Page 86: ...er transmit or not transmit Start Stop characters Default Don t Transmit Codabar Check Character Codabar check characters are created using different modulos You can program the scanner to read only Codabar bar codes with Modulo 16 check characters Default No Check Character No Check Character indicates that the scanner reads and transmits bar code data with or without a check character When Check...

Page 87: ... scanner from decoding a single D Codabar symbol without its companion This selection has no effect on Codabar symbols without Stop Start D characters Codabar Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 1 for additional information Minimum and Maximum lengths 2 60 Minimum Default 4 Maximum Default 60 Validate Modulo 16 but Don t T...

Page 88: ... data with or without a check character When Check Character is set to Validate but Don t Transmit the unit only reads Code 39 bar codes printed with a check character but will not transmit the check character with the scanned data When Check Character is set to Validate and Transmit the scanner only reads Code 39 bar codes printed with a check character and will transmit this character at the end...

Page 89: ...hen the scanner encounters a Code 39 bar code with the append trigger character s it buffers Code 39 bar codes until it reads a Code 39 bar code that does not have the append trigger The data is then transmitted in the order in which the bar codes were read FIFO Default Off Code 32 Pharmaceutical PARAF Code 32 Pharmaceutical is a form of the Code 39 symbology used by Italian pharmacies This symbol...

Page 90: ...If this is the case scan the bar code below select the code page with which the bar codes were created see ISO 2022 ISO 646 Character Replacements on page A 8 and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual The data characters should then appear properly NUL U DLE P SP SPACE 0 0 V P P W p P SOH A DC1 Q A 1 1 A A Q Q a A q Q STX B DC2 ...

Page 91: ...eck digit with the scanned data When Check Digit is set to Validate and Transmit the scanner only reads Interleaved 2 of 5 bar codes printed with a check digit and will transmit this digit at the end of the scanned data Default No Check Digit Interleaved 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 1 for additional informati...

Page 92: ...ansmit the unit only reads NEC 2 of 5 bar codes printed with a check digit but will not transmit the check digit with the scanned data When Check Digit is set to Validate and Transmit the scanner only reads NEC 2 of 5 bar codes printed with a check digit and will transmit this digit at the end of the scanned data Default No Check Digit Maximum Message Length On Off No Check Digit Validate but Don ...

Page 93: ...Default 4 Maximum Default 80 Code 93 Default All Code 93 Settings Code 93 On Off Code 93 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 1 for additional information Minimum and Maximum lengths 0 80 Minimum Default 0 Maximum Default 80 Minimum Message Length Maximum Message Length On Off Minimum Message Length Maximum Message Length ...

Page 94: ...ode 93 bar code that starts with a character other than a space Default Off Code 93 Code Page Code pages define the mapping of character codes to characters If the data received does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code belo...

Page 95: ...of 5 Industrial On Off Straight 2 of 5 Industrial Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 1 for additional information Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 On Off Minimum Message Length Maximum Message Length ...

Page 96: ...f 5 IATA On Off Straight 2 of 5 IATA Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 1 for additional information Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 On Off Minimum Message Length Maximum Message Length ...

Page 97: ...Matrix 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 1 for additional information Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 On Off Minimum Message Length Maximum Message Length ...

Page 98: ...de 11 bar codes Default Two Check Digits Code 11 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 1 for additional information Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 On Off One Check Digit Two Check Digits Minimum Message Length Maximum Message Length ...

Page 99: ...rent recommendation to use Code 128 due to its high degree of security and its space efficient design 3 a variation of Code 128 that supports concatenation of neigh boring symbols and 4 the standard layout for bar codes on a blood product label Use the bar codes below to turn concat enation on or off Default Off Code 128 Message Length Scan the bar codes below to change the message length Refer to...

Page 100: ...lt On Code 128 Code Page Code pages define the mapping of character codes to characters If the data received does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see ISO ...

Page 101: ...8 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 1 for additional information Minimum and Maximum lengths 1 80 Minimum Default 1 Maximum Default 80 On Off Minimum Message Length Maximum Message Length ...

Page 102: ...eads symbols with start stop pattern 1 and decodes them as compressed numeric with optional full ASCII start stop pattern 2 Default AIM Telepen Output Telepen Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 1 for additional information Minimum and Maximum lengths 1 60 Minimum Default 1 Maximum Default 60 On Off AIM Telepen Output Orig...

Page 103: ...git This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not Default On UPC A Number System The numeric system digit of a U P C symbol is normally transmitted at the beginning of the scanned data but the unit can be programmed so it will not transmit it Default On On Off On Off On Off ...

Page 104: ...y read UPC A bar codes that have addenda You must then turn on a 2 or 5 digit addenda listed on page 7 20 Default Not Required UPC A Addenda Separator When this feature is on there is a space between the data from the bar code and the data from the addenda When turned off there is no space Default On 2 Digit Addenda On 2 Digit Addenda Off 5 Digit Addenda On 5 Digit Addenda Off Required Not Require...

Page 105: ...y Otherwise it transmits the first coupon code it reads If you scan the Require Concatenation code the scanner must see and read the coupon code and extended coupon code in a single read to transmit the data No data is output unless both codes are read Default Off Coupon GS1 DataBar Output If you scan coupons that have both UPC and GS1 DataBar codes you may wish to scan and output only the data fr...

Page 106: ...u need to read codes that lead with the 1 number system use UPC E1 page 7 24 Default On UPC E0 Expand UPC E Expand expands the UPC E code to the 12 digit UPC A format Default Off UPC E0 Addenda Required When Required is scanned the scanner will only read UPC E bar codes that have addenda Default Not Required UPC E0 On UPC E0 Off On Off Required Not Required ...

Page 107: ...e check digit should be transmitted at the end of the scanned data or not Default On UPC E0 Leading Zero This feature allows the transmission of a leading zero 0 at the beginning of scanned data To prevent transmission scan Off Default On UPC E0 Addenda This selection adds 2 or 5 digits to the end of all scanned UPC E data Default Off for both 2 Digit and 5 Digit Addenda On Off On Off On Off 2 Dig...

Page 108: ...ion Default Off EAN JAN 13 Default All EAN JAN Settings EAN JAN 13 On Off Convert UPC A to EAN 13 When UPC A Converted to EAN 13 is selected UPC A bar codes are converted to 13 digit EAN 13 codes by adding a zero to the front When Do not Convert UPC A is selected UPC A codes are read as UPC A 5 Digit Addenda On 5 Digit Addenda Off UPC E1 On UPC E1 Off On Off UPC A Converted to EAN 13 ...

Page 109: ... This selection adds 2 or 5 digits to the end of all scanned EAN JAN 13 data Default Off for both 2 Digit and 5 Digit Addenda EAN JAN 13 Addenda Required When Required is scanned the scanner will only read EAN JAN 13 bar codes that have addenda Default Not Required Do not Convert UPC A On Off 2 Digit Addenda On 2 Digit Addenda Off 5 Digit Addenda On 5 Digit Addenda Off Required ...

Page 110: ...addenda When turned Off there is no space Default On Note If you want to enable or disable EAN13 with Extended Coupon Code refer to UPC A EAN 13 with Extended Coupon Code page 7 21 ISBN Translate When On is scanned EAN 13 Bookland symbols are translated into their equivalent ISBN number format Default Off Not Required On Off On Off ...

Page 111: ...specify whether the check digit should be transmitted at the end of the scanned data or not Default On EAN JAN 8 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN JAN 8 data Default Off for both 2 Digit and 5 Digit Addenda On Off On Off 2 Digit Addenda On 2 Digit Addenda Off 5 Digit Addenda On ...

Page 112: ...EAN JAN 8 bar codes that have addenda Default Not Required EAN JAN 8 Addenda Separator When this feature is On there is a space between the data from the bar code and the data from the addenda When turned Off there is no space Default On 5 Digit Addenda Off Required Not Required On Off ...

Page 113: ...rinted with the specified type check character s and will transmit the character s at the end of the scanned data When Check Character is set to Validate Type 10 11 but Don t Transmit the unit will only read MSI bar codes printed with the specified type check character s but will not transmit the check character s with the scanned data On Off Validate Type 10 but Don t Transmit Validate Type 10 an...

Page 114: ...ngth Refer to Message Length Description page 7 1 for additional information Minimum and Maximum lengths 4 48 Minimum Default 4 Maximum Default 48 Validate Type 11 then Type 10 Character and Transmit Disable MSI Check Characters Minimum Message Length Maximum Message Length ...

Page 115: ... DataBar Omnidirectional Default All GS1 DataBar Omnidirectional Settings GS1 DataBar Omnidirectional On Off GS1 DataBar Limited Default All GS1 DataBar Limited Settings GS1 DataBar Limited On Off On Off On Off ...

Page 116: ...ge length Refer to Message Length Description page 7 1 for additional information Minimum and Maximum lengths 4 74 Minimum Default 4 Maximum Default 74 Trioptic Code Note If you are going to scan Code 32 Pharmaceutical codes page 7 5 Trioptic Code must be off Trioptic Code is used for labeling magnetic storage media On Off Minimum Message Length Maximum Message Length On Off ...

Page 117: ...ablock A Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 1 for additional information Minimum and Maximum lengths 1 600 Minimum Default 1 Maximum Default 600 On Off Minimum Message Length Maximum Message Length ...

Page 118: ...block F Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 1 for additional information Minimum and Maximum lengths 1 2048 Minimum Default 1 Maximum Default 2048 On Off Minimum Message Length Maximum Message Length ...

Page 119: ...al information Minimum and Maximum lengths 1 2750 Minimum Default 1 Maximum Default 2750 MacroPDF417 MacroPDF417 is an implementation of PDF417 capable of encoding very large amounts of data into multiple PDF417 bar codes When this selection is enabled these multiple bar codes are assembled into a single data string Default On On Off Minimum Message Length Maximum Message Length On Off ...

Page 120: ... 7 1 for additional information Minimum and Maximum lengths 1 366 Minimum Default 1 Maximum Default 366 GS1 Composite Codes Linear codes are combined with a unique 2D composite component to form a new class called GS1 Composite symbology GS1 Composite symbologies allow for the co existence of symbologies already in use Default Off On Off Minimum Message Length Maximum Message Length On Off ...

Page 121: ...nclude UPC A and UPC E EAN 13 and EAN 8 ITF 14 GS1 128 and GS1 128 DataBar and GS1 Composites Any application that accepts GS1 data can be simplified since it only needs to recog nize one data carrier type If GS1 128 Emulation is scanned all retail codes U P C UPC E EAN8 EAN13 are expanded out to 16 digits If the AIM ID is enabled the value will be the GS1 128 AIM ID C1 see Symbology Charts on pag...

Page 122: ...he Code 39 linear component The MicroPDF417 component can only be decoded if TLC39 On is selected The linear component may be decoded as Code 39 even if TLC39 is off Default Off QR Code Default All QR Code Settings QR Code On Off This selection applies to both QR Code and Micro QR Code GS1 DataBar Emulation GS1 Code Expansion Off EAN8 to EAN13 Conversion GS1 Emulation Off On Off On Off ...

Page 123: ...e proper number of codes is reached the data is output in the order specified in the bar codes Default On QR Code Page QR Code pages define the mapping of character codes to characters If the data received does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the...

Page 124: ...If the data received does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see ISO 2022 ISO 646 Character Replacements on page A 8 and scan the value and the Save bar code...

Page 125: ...de Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 1 for additional information Minimum and Maximum lengths 1 150 Minimum Default 1 Maximum Default 150 On Off Minimum Message Length Maximum Message Length ...

Page 126: ...ar code with the append trigger character s it buffers the number of Aztec bar codes determined by information encoded in those bar codes Once the proper number of codes is reached the data is output in the order specified in the bar codes Default On Aztec Code Page Aztec Code pages define the mapping of character codes to characters If the data received does not display with the proper characters...

Page 127: ...ters should then appear properly Chinese Sensible Han Xin Code Default All Han Xin Settings Han Xin Code On Off Han Xin Code Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 1 for additional information Minimum and Maximum lengths 1 7833 Minimum Default 1 Maximum Default 7833 Aztec Code Page On Off Minimum Message Length Maximum Messag...

Page 128: ...an be active at a time If you scan a second 2D postal code selection the first selection is overwritten Default 2D Postal Codes Off Single 2D Postal Codes 2D Postal Codes Off Australian Post On British Post On Canadian Post On Intelligent Mail Bar Code On Japanese Post On KIX Post On Planet Code On Also see Planet Code Check Digit page 7 47 Postal 4i On ...

Page 129: ... and B Fields On InfoMail On InfoMail and British Post On Intelligent Mail Bar Code and Postnet with B and B Fields On Postnet and Postal 4i On Postnet and Intelligent Mail Bar Code On Postal 4i and Intelligent Mail Bar Code On Postal 4i and Postnet with B and B Fields On Planet Code and Postnet On ...

Page 130: ...On Planet Code Postnet and Intelligent Mail Bar Code On Planet Code Postal 4i and Intelligent Mail Bar Code On Postnet Postal 4i and Intelligent Mail Bar Code On Planet Code Postal 4i and Postnet with B and B Fields On Planet Code Intelligent Mail Bar Code and Postnet with B and B Fields On Postal 4i Intelligent Mail Bar Code and Postnet with B and B Fields On ...

Page 131: ...ation is applied to customer fields in Australian 4 State symbols Bar Output lists the bar patterns in 0123 format Numeric N Table causes that field to be interpreted as numeric data using the N Table Alphanumeric C Table causes the field to be interpreted as alphanumeric data using the C Table Refer to the Australian Post Specification Tables Planet Code Postal 4i Intelligent Mail Bar Code and Po...

Page 132: ...ong Kong 2 of 5 Default All China Post Hong Kong 2 of 5 Settings China Post Hong Kong 2 of 5 On Off China Post Hong Kong 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 1 for addi tional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 80 Bar Output Numeric N Table Alphanumeric C Table Combination ...

Page 133: ...cription page 7 1 for addi tional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 48 Korea Post Check Digit This selection allows you to specify whether the check digit should be transmitted Default Don t Transmit Maximum Message Length On Off Minimum Message Length Maximum Message Length Transmit Check Digit Don t Transmit Check Digit ...

Page 134: ...7 50 ...

Page 135: ...e Capture IMGBOX page 8 10 The modifiers for each of these commands follow the command description Note The images included with each command description are examples only The results you achieve may be different from those included in this manual The quality of the output you receive will vary depending on lighting quality of the initial image object being captured and distance of the scanner fro...

Page 136: ...the exposure time This is similar to setting a shutter speed on a camera The exposure time determines how long the scanner takes to record an image On a bright day expo sure times can be very short because plenty of light is available to help record an image At nighttime exposure time can increase dramatically due to the near absence of light Units are 127 microseconds Default 7874 nE Range 1 7874...

Page 137: ... or below the target white value and 25 of the pixels are above the target white value Altering this setting from the default is not recommended under normal circumstances To alter grayscale values W Target White Value should be used Default 50 n Range 1 99 Step 2 Ship a Picture Using IMGSHP Image Ship IMGSHP An image is taken whenever the button is pushed or when the Image Snap IMGSNP command is ...

Page 138: ...variations in illumination across the image 0C Compensation disabled default 1C Compensation enabled D Pixel Depth Indicates the number of bits per pixel in the transmitted image KIM or BMP format only 8D 8 bits per pixel grayscale image default 1D 1 bit per pixel black and white image Example of Infinity Filter off 0A from approximately 12 feet 3 66m away Example of Infinity Filter on 1A from app...

Page 139: ...or the image 0F KIM format 1F TIFF binary 2F TIFF binary group 4 compressed 3F TIFF grayscale 4F Uncompressed binary upper left to lower right 1 pixel bit 0 padded end of line 5F Uncompressed grayscale upper left to lower right bitmap format 6F JPEG image default 8F BMP format lower right to upper left uncompressed H Histogram Stretch Increases the contrast of the transmitted image Not available w...

Page 140: ...t and pepper noise in an image 0if No salt and pepper noise reduction default 1if Salt and pepper noise reduction Example of image with Invert Image set to 1ix Example of image not inverted Example of image with Invert Image set to 1iy Example of Noise Reduction On 1if Example of Noise Reduction Off 0if ...

Page 141: ...est file K Gamma Correction Gamma measures the brightness of midtone values produced by the image You can brighten or darken an image using gamma correction A higher gamma correction yields an overall brighter image The lower the setting the darker the image The optimal setting for text images is 50K 0K Gamma correction off default 50K Apply gamma correction for brightening typical document image ...

Page 142: ...the bottom of the image Ship the remaining center pixels Range 0 238 Default 0 or full image P Protocol Used for shipping an image Protocol covers two features of the image data being sent to the host It addresses the proto col used to send the data Hmodem which is an Xmodem 1K variant that has additional header information and the for mat of the image data that is sent 0P None raw data 2P None de...

Page 143: ...grayscale threshold n Use lower numbers when the image contrast is lower 1U will have a similar effect to setting E Edge Sharpen page 8 5 to 22e Range 0 255 V Blur Image Smooths transitions by averaging the pixels next to the hard edges of defined lines and shaded areas in an image 0V Don t blur default 1V Blur W Histogram Ship A histogram gives a quick picture of the tonal range of an image or ke...

Page 144: ...nature area as well as specify how far the signature area is from the bar code vertically and horizontally You can also set the resolution and file format for the final output of the signature capture image Note IMGBOX commands can only be triggered by one of the following types of bar codes PDF417 Code 39 Code 128 Aztec Codabar and Interleaved 2 of 5 Once one of these symbologies has been read th...

Page 145: ... after the button push Example IMGBOX245w37h55y Note Case is not important in the command string It is used here only for clarity The following image is captured The IMGBOX commands have many different modifiers that can be used to change the size and appearance of the signature image output by the scanner Modifiers affect the image that is transmitted but do not affect the image in memory Any num...

Page 146: ...scale 6F JPEG image default 7F Outlined image 8F BMP format H Height of Signature Capture Area The height of the signature capture area must be measured in inches divided by 01 In the example the height of the area to be captured is 3 8 inch resulting in a value of H 375 0 01 37 5 K Gamma Correction Gamma measures the brightness of midtone values produced by the image You can brighten or darken an...

Page 147: ... the minimum element size of the bar code The bar code aspect ratio allows you to set the ratio of the bar code height to the narrow element width In the example the narrow ele ment width is 010 inches and the bar code height is 0 400 inches resulting in a value of S 0 4 0 01 40 W Width of Signature Capture Area The width of the signature capture area must be measured in inches divided by 01 In th...

Page 148: ...h Y Vertical Bar Code Offset The vertical bar code offset allows you to offset the vertical center of the signature capture area Negative numbers indi cate that the signature capture is above the bar code and positive numbers indicate that the area is below the bar code Measurements are in multiples of the minimum bar width Example of Horizontal Offset set to 75X Example of Horizontal Offset set t...

Page 149: ... following chart indicates the equiva lents of these five characters for different countries Function Code HEX ASCII Value Full ASCII CTRL X Mode NUL 00 SOH 01 A STX 02 B ETX 03 C EOT 04 D ENQ 05 E ACK 06 F BEL 07 G BS 08 H HT 09 I LF 0A J VT 0B K FF 0C L CR 0D M SO 0E N SI 0F O DLE 10 P DC1 11 Q DC2 12 R DC3 13 S DC4 14 T NAK 15 U SYN 16 V ETB 17 W CAN 18 X EM 19 Y SUB 1A Z ESC 1B FS 1C GS 1D RS ...

Page 150: ...9 2 Denmark 8 9 6 Norway 8 9 6 Spain 6 Country Codes ...

Page 151: ... 06 CTRL break CNTRL break BEL 07 CR Enter RETURN BS 08 Reserved APPLE make HT 09 Tab TAB LF 0A Reserved APPLE break VT 0B Tab TAB FF 0C Delete Del CR 0D CR Enter RETURN SO 0E Insert Ins Help SI 0F Escape ESC DLE 10 F11 F11 DC1 11 Home Home DC2 12 Print Prnt Scrn DC3 13 Back Space BACKSPACE DC4 14 Back Tab LSHIFT TAB NAK 15 F12 F12 SYN 16 F1 F1 ETB 17 F2 F2 CAN 18 F3 F3 EM 19 F4 F4 SUB 1A F5 F5 ES...

Page 152: ...9 4 ...

Page 153: ...removed when the unit is power cycled Show Decoder Revision Scan the bar code below to output the decoder revision Show Scan Driver Revision Scan the bar code below to output the scan driver revision The scan driver controls image capture Show Software Revision Scan the bar code below to output the current software revision unit serial number and other product information for the scan ner Show Dat...

Page 154: ...canner Decoding apps and Data Formatting apps can be created using TotalFreedom For further information about TotalFreedom go to our website at www honeywellaidc com Application Plug Ins Apps Any apps that you are using can be turned off or on by scanning the following bar codes Apps are stored in groups Decoding and Formatting You can enable and disable these groups of apps by scanning that group...

Page 155: ...one of these tree nodes is clicked the right hand side is loaded with the parameters form belonging to that particular category The Configure tree option has all the programming and con figuration parameters specified for a scanner You can set or modify these parameters as required You can later write the modified settings to the scanner or save them to a dcf file Imaging Imaging provides all the ...

Page 156: ...m Defaults bar code then scan Activate Defaults This resets the scanner to the factory default settings The Menu Commands beginning on page 11 4 list the factory default settings for each of the commands indicated by an aster isk on the programming pages This selection erases all your settings and resets the scanner to the original factory defaults It also disables all plugins Remove Custom Defaul...

Page 157: ...or example the SubTag for the RS232 baud rate is BAD Data The new value for a menu setting identified by the Tag and SubTag Storage A single character that specifies the storage table to which the command is applied An exclamation point performs the command s operation on the device s volatile menu configuration table A period performs the command s operation on the device s non volatile menu conf...

Page 158: ...vice echoes back the command sequence with the status character inserted directly before each of the punctuation marks the period exclamation point comma or semicolon in the command Examples of Query Commands In the following examples a bracketed notation depicts a non displayable response Example What is the range of possible values for Codabar Coding Enable Enter cbrena Response CBRENA0 1 ACK Th...

Page 159: ...scans until a bar code has been read until the deactivate command is sent or until the serial time out has been reached see Read Time Out on page 3 5 for a description and the serial command on page 11 8 Resetting the Custom Defaults If you want the custom default settings restored to your scanner scan the Activate Custom Defaults bar code below This resets the scanner to the custom default settin...

Page 160: ...board Mac PAP125 2 2 USB Japanese Keyboard PC TRMUSB134 2 2 USB HID PAP131 2 2 USB Serial TRMUSB130 2 3 CTS RTS Emulation On USBCTS1 2 3 CTS RTS Emulation Off USBCTS0 2 3 ACK NAK Mode On USBACK1 2 3 ACK NAK Mode Off USBACK0 2 3 Remote MasterMind for USB ReM Off REMIFC0 2 3 ReM On ReMIFC1 2 3 Plug and Play Codes Verifone Ruby Terminal PAPRBY 2 4 Gilbarco Terminal PAPGLB 2 4 Honeywell Bioptic Aux Po...

Page 161: ...eek 319 Latin KBDCTY65 2 9 Greek 319 KBDCTY62 2 9 Greek Latin KBDCTY63 2 9 Greek MS KBDCTY66 2 9 Greek Polytonic KBDCTY60 2 9 Hebrew KBDCTY12 2 9 Hungarian 101 key KBDCTY50 2 9 Hungary KBDCTY19 2 9 Iceland KBDCTY75 2 10 Irish KBDCTY73 2 10 Italian 142 KBDCTY56 2 10 Italy KBDCTY5 2 10 Japan ASCII KBDCTY28 2 10 Kazakh KBDCTY78 2 10 Kyrgyz Cyrillic KBDCTY79 2 10 Latin America KBDCTY14 2 10 Latvia KBD...

Page 162: ...Y76 2 13 United Kingdom KBDCTY7 2 13 United Stated Dvorak right KBDCTY89 2 13 United States Dvorak left KBDCTY88 2 13 United States Dvorak KBDCTY87 2 13 United States International KBDCTY30 2 14 Uzbek Cyrillic KBDCTY77 2 14 Keyboard Conversion Keyboard Conversion Off KBDCNV0 2 15 Convert all Characters to Upper Case KBDCNV1 2 15 Convert all Characters to Lower Case KBDCNV2 2 15 Keyboard Style Regu...

Page 163: ... Stop Parity None 232WRD0 2 20 7 Data 1 Stop Parity Odd 232WRD6 2 20 7 Data 2 Stop Parity Even 232WRD4 2 20 7 Data 2 Stop Parity None 232WRD1 2 20 7 Data 2 Stop Parity Odd 232WRD7 2 20 8 Data 1 Stop Parity Even 232WRD5 2 20 8 Data 1 Stop Parity None 232WRD2 2 20 8 Data 1 Stop Parity Odd 232WRD8 2 20 8 Data 1 Stop Parity Mark 232WRD14 2 20 RS232 Receiver Time out Range 0 300 seconds 232LPT 2 21 RS2...

Page 164: ...eper Pitch Error Frequency Razz 250 min 200Hz BEPFQ2250 3 3 Medium 3250 BEPFQ23250 3 3 High 4200 max 9000Hz BEPFQ24200 3 3 Beeper Duration Good Read Normal Beep BEPBIP0 3 3 Short Beep BEPBIP1 3 3 LED Good Read Off BEPLED0 3 3 On BEPLED1 3 3 Number of Beeps Error 1 BEPERR1 3 4 Range 1 9 BEPERR 3 4 Number of Beeps Good Read 1 BEPRPT1 3 4 Range 1 9 BEPRPT 3 4 Good Read Delay No Delay DLYGRD0 3 4 Shor...

Page 165: ...9 Streaming Presentation Mobile Phone PAPSPC 3 9 Hands Free Time Out Range 0 300 000 ms TRGPTO 3 9 Character Activation Mode Off HSTCEN0 3 10 On HSTCEN1 3 10 Activation Character HSTACH 3 10 Do Not End Character Activation After Good Read HSTCGD0 3 11 End Character Activation After Good Read HSTCGD1 3 11 Character Activation Laser Timeout Range 1 65525 5000 ms HSTCDT 3 10 Character Deactivation Mo...

Page 166: ...QBLK 3 18 Default Sequence SEQDFT 3 18 Partial Sequence Transmit Partial Sequence SEQTTS1 3 18 Discard Partial Sequence SEQTTS0 3 19 Require Output Sequence Required SEQ_EN2 3 19 On Not Required SEQ_EN1 3 19 Off SEQ_EN0 3 19 Multiple Symbols On SHOTGN1 3 19 Off SHOTGN0 3 19 No Read On SHWNRD1 3 19 Off SHWNRD0 3 20 Video Reverse Video Reverse Only VIDREV1 3 20 Video Reverse and Standard Bar Codes V...

Page 167: ...M_EN1 5 12 Data Format Required Keep Prefix Suffix DFM_EN2 5 12 Data Formatter On Not Required Drop Prefix Suffix DFM_EN3 5 12 Data Format Required Drop Prefix Suffix DFM_EN4 5 12 Data Format Non Match Error Tone Data Format Non Match Error Tone On DFMDEC0 5 12 Data Format Non Match Error Tone Off DFMDEC1 5 12 Primary Alternate Data Formats Primary Data Format ALTFNM0 5 12 Data Format 1 ALTFNM1 5 ...

Page 168: ...th Minimum 2 60 4 CBRMIN 7 3 Maximum 2 60 60 CBRMAX 7 3 Code 39 Default All Code 39 Settings C39DFT 7 4 Off C39ENA0 7 4 On C39ENA1 7 4 Code 39 Start Stop Char Don t Transmit C39SSX0 7 4 Transmit C39SSX1 7 4 Code 39 Check Char No Check Char C39CK20 7 4 Validate But Don t Transmit C39CK21 7 4 Validate and Transmit C39CK22 7 4 Code 39 Message Length Minimum 0 48 0 C39MIN 7 5 Maximum 0 48 48 C39MAX 7 ...

Page 169: ...C93MIN 7 9 Maximum 0 80 80 C93MAX 7 9 Code 93 Append On C93APP1 7 10 Off C93APP0 7 10 Code 93 Code Page Code 93 Code Page C93DCP 7 10 Straight 2 of 5 Industrial Default All Straight 2 of 5 Industrial Settings R25DFT 7 11 Off R25ENA0 7 11 On R25ENA1 7 11 Straight 2 of 5 Industrial Message Length Minimum 1 48 4 R25MIN 7 11 Maximum 1 48 48 R25MAX 7 11 Straight 2 of 5 IATA Default All Straight 2 of 5 ...

Page 170: ...128 Default All GS1 128 Settings GS1DFT 7 17 On GS1ENA1 7 17 Off GS1ENA0 7 17 GS1 128 Message Length Minimum 1 80 1 GS1MIN 7 17 Maximum 0 80 80 GS1MAX 7 17 Telepen Default All Telepen Settings TELDFT 7 18 Off TELENA0 7 18 On TELENA1 7 18 Telepen Output AIM Telepen Output TELOLD0 7 18 Original Telepen Output TELOLD1 7 18 Telepen Message Length Minimum 1 60 1 TELMIN 7 18 Maximum 1 60 60 TELMAX 7 18 ...

Page 171: ...UPECKX0 7 23 On UPECKX1 7 23 UPC E0 Number System Off UPENSX0 7 23 On UPENSX1 7 23 UPC E0 Addenda 2 Digit Addenda On UPEAD21 7 23 2 Digit Addenda Off UPEAD20 7 23 5 Digit Addenda On UPEAD51 7 24 5 Digit Addenda Off UPEAD50 7 24 UPC E1 Off UPEEN10 7 24 On UPEEN11 7 24 EAN JAN 13 Default All EAN JAN Settings E13DFT 7 24 Off E13ENA0 7 24 On E13ENA1 7 24 Convert UPC A to EAN 13 UPC A Converted to EAN ...

Page 172: ...e 10 but Don t Transmit MSICHK0 7 29 Validate Type 10 and Transmit MSICHK1 7 29 Validate 2 Type 10 Chars but Don t Transmit MSICHK2 7 29 Validate 2 Type 10 Chars and Transmit MSICHK3 7 29 Validate Type 11 then Type 10 Char but Don t Transmit MSICHK4 7 29 Validate Type 11 then Type 10 Char and Transmit MSICHK5 7 30 Disable MSI Check Characters MSICHK6 7 30 MSI Message Length Minimum 4 48 4 MSIMIN 7...

Page 173: ...2750 PDFMAX 7 35 MacroPDF417 On PDFMAC1 7 35 Off PDFMAC0 7 35 MicroPDF417 Default All Micro PDF417 Settings MPDDFT 7 36 On MPDENA1 7 36 Off MPDENA0 7 36 MicroPDF417 Msg Length Minimum 1 366 1 MPDMIN 7 36 Maximum 1 366 366 MPDMAX 7 36 GS1 Composite Codes On COMENA1 7 36 Off COMENA0 7 36 UPC EAN Version On COMUPC1 7 37 Off COMUPC0 7 37 GS1 Composite Codes Msg Length Minimum 1 2435 1 COMMIN 7 37 Maxi...

Page 174: ... 7 42 Maximum 1 3832 3832 AZTMAX 7 42 Aztec Append On AZTAPP1 7 42 Off AZTAPP0 7 42 Aztec Code Page Aztec Code Page 51 AZTDCP 7 43 Chinese Sensible Han Xin Code Default All Han Xin Code Settings HX_DFT 7 43 On HX_ENA1 7 43 Off HX_ENA0 7 43 Chinese Sensible Han Xin Code Msg Length Minimum 1 7833 1 HX_MIN 7 43 Maximum 1 7833 7833 HX_MAX 7 43 Postal Codes 2D 2D Postal Codes Off POSTAL0 7 44 Single 2D...

Page 175: ...POSTAL26 7 46 Postal 4i Intelligent Mail Bar Code and Postnet with B and B Fields On POSTAL27 7 46 Planet Postal 4i Intelligent Mail Bar Code and Postnet On POSTAL28 7 47 Planet Postal 4i Intelligent Mail Bar Code and Postnet with B and B Fields On POSTAL29 7 46 Planet Code Check Digit Transmit PLNCKX1 7 47 Don t Transmit PLNCKX0 7 47 Postnet Check Digit Transmit NETCKX1 7 47 Don t Transmit NETCKX...

Page 176: ...L 8 3 Update Tries 0 10 6 SNPTRY 8 3 Target Set Point Percentage 1 99 50 SNPPCT 8 3 Image Ship Infinity Filter Off IMGINF0 8 4 Infinity Filter On IMGINF1 8 4 Compensation Off IMGCOR0 8 4 Compensation On IMGCOR1 8 4 Pixel Depth 8 bits pixel grayscale IMGBPP8 8 4 Pixel Depth 1 bit pixel B W IMGBPP1 8 4 Don t Sharpen Edges IMGEDG0 8 5 Sharpen Edges 0 23 IMGEDG 8 5 File Format JPEG IMGFMT6 8 5 File Fo...

Page 177: ...otocol Hmodem Compressed IMGXFR3 8 8 Protocol Hmodem IMGXFR4 8 8 Ship Every Pixel IMGSUB1 8 8 Ship Every 2nd Pixel IMGSUB2 8 8 Ship Every 3rd Pixel IMGSUB3 8 9 Document Image Filter Off IMGUSH0 8 9 Document Image Filter On 0 255 IMGUSH 8 9 Don t Ship Histogram IMGHST0 8 9 Ship Histogram IMGHST1 8 9 Image Size Compatibility Force VGA Resolution IMGVGA1 8 10 Native Resolution IMGVGA0 8 10 Intelligen...

Page 178: ...f PLGDCE0 10 2 Formatting Apps On PLGFOE1 10 2 Formatting Apps Off PLGFOE0 10 2 List Apps PLGINF 10 2 Resetting the Factory Defaults Remove Custom Defaults DEFOVR 10 4 Activate Defaults DEFALT 10 4 Selection Setting Indicates default Serial Command Indicates a numeric entry Page ...

Page 179: ...second for 13 mil UPC Symbol Contrast Grade 1 0 20 or greater Voltage Requirements 4 5 5 VDC at input connector Current Draw 5VDC Scanning Standby 450mA 2 3W 90mA 45W Power Supply Noise Rejection Maximum 100mV peak to peak 10 to 100 kHz Temperature Ranges Operating 32 F to 104 F 0 C to 40 C Storage 4 F to 158 F 20 C to 70 C Humidity 5 to 95 non condensing Mechanical Drop Operational after 30 drops...

Page 180: ...39 435 30 190 59 516 10 mil Data Matrix in 1 85 8 50 63 5 59 4 76 10 79 mm 47 216 16 142 121 274 20 mil Data Matrix in 1 30 16 30 75 8 23 2 05 19 13 mm 33 414 19 209 52 486 Focus Standard Range SR High Density HD Extended Range ER Symbology Near Distance Far Distance Near Distance Far Distance Near Distance Far Distance 5 mil Code 39 in 2 52 5 71 1 18 4 68 5 79 8 82 mm 64 145 30 119 147 224 13 mil...

Page 181: ...gles should be avoided Other factors such as surface qualities mounting distances secondary windows and external illumination can easily impact these recommendations If a secondary window is used the window should be mounted as close to the front of scanner as possible at a 90 angle to the optical axis to avoid specular reflections For secondary windows Honeywell recommends the following Optical q...

Page 182: ...may lead to damage to the unit Use of any cables not provided by the manufacturer may result in damage not covered by your warranty Ө 15 Pin D type 1 PC Data 2 KB Clock 3 KB Data 4 Reserved 5 Reserved 6 Ground 7 Reserved 8 Jump to Pin 11 9 PC Clock 10 Host Power 5V 11 Adapter Power 12 Jump to Pin 10 13 Reserved 14 Reserved 15 Reserved 5 6 11 1 15 10 ...

Page 183: ...t provided by the manufacturer may result in damage not covered by your warranty 15 Pin D type 1 Reserved 2 Reserved 3 Reserved 4 Reserved 5 Reserved 6 Ground 7 TXD 8 RXD 9 Reserved 10 Reserved 11 Adapter Power 12 CTS 13 RTS 14 External Trigger 15 External Illumination 5 6 11 1 15 10 15 Pin D type 1 Reserved 2 Reserved 3 Reserved 4 USB D 5 USB D 6 Ground 7 Reserved 8 Reserved 9 Reserved 10 Host Po...

Page 184: ...12 6 Required Safety Labels Scanner Compliance Label location Part Number Serial Number and Revision Information location Illumination output ...

Page 185: ...ch 10 Gentle dish soap and water Inspecting Cords and Connectors Inspect the interface cable and connector for wear or other signs of damage A badly worn cable or damaged connector may interfere with scanner operation Contact your distributor for information about cable replacement Cable replacement instructions are on page 13 1 Replacing Cables The standard interface cable is attached to the scan...

Page 186: ...cratched or exhibiting voids Aren t coated with frost or water droplets on the surface Are enabled in the scanner or in the decoder to which the scanner connects Is the bar code displayed but not entered The bar code is displayed on the host device correctly but you still have to press a key to enter it the Enter Return key or the Tab key for example You need to program a suffix Programming a suff...

Page 187: ...bar Fm 0 1 a 61 Code 11 H3 h 68 Code 128 Cm 0 1 2 4 j 6A Code 32 Pharmaceutical PARAF X0 3C Code 39 supports Full ASCII mode Am 0 1 3 4 5 7 b 62 TCIF Linked Code 39 TLC39 L2 T 54 Code 93 and 93i Gm 0 9 A Z a m i 69 EAN Em 0 1 3 4 d 64 EAN 13 including Bookland EAN E0 d 64 EAN 13 with Add On E3 d 64 EAN 13 with Extended Coupon Code E3 d 64 EAN 8 E4 D 44 EAN 8 with Add On E3 D 44 GS1 GS1 DataBar em ...

Page 188: ...3 UPC A with Extended Coupon Code E3 c 63 UPC E E0 E 45 UPC E with Add On E3 E 45 UPC E1 X0 E 45 Add Honeywell Code ID 5C80 Add AIM Code ID 5C81 Add Backslash 5C5C Batch mode quantity 5 35 AIM Honeywell Symbology ID Possible modifiers m ID Hex ...

Page 189: ...an Xin Code X0 H 48 Codablock A O6 0 1 4 5 6 V 56 Codablock F Om 0 1 4 5 6 q 71 Code 49 Tm 0 1 2 4 l 6C Data Matrix dm 0 6 w 77 GS1 em 0 3 y 79 GS1 Composite em 0 3 y 79 GS1 DataBar Omnidirectional em 0 3 y 79 MaxiCode Um 0 3 x 78 PDF417 Lm 0 2 r 72 MicroPDF417 Lm 0 5 R 52 QR Code Qm 0 6 s 73 Micro QR Code Qm s 73 AIM Honeywell Symbology ID Possible modifiers m ID Hex All Symbologies 99 Australian...

Page 190: ...d 7 07 BEL Enter Ret CTRL G 8 08 BS Apple Make CTRL H History 9 09 HT Tab CTRL I Italic 10 0A LF Apple Break CTRL J Justify 11 0B VT Tab CTRL K hyperlink 12 0C FF Delete CTRL L list left align 13 0D CR Enter Ret CTRL M 14 0E SO Insert CTRL N New 15 0F SI ESC CTRL O Open 16 10 DLE F11 CTRL P Print 17 11 DC1 Home CTRL Q Quit 18 12 DC2 PrtScn CTRL R 19 13 DC3 Backspace CTRL S Save 20 14 DC4 Back Tab ...

Page 191: ...90 5A Z 122 7A z 59 3B 91 5B 123 7B 60 3C 92 5C 124 7C 61 3D 93 5D 125 7D 62 3E 94 5E 126 7E 63 3F 95 5F _ 127 7F Extended ASCII Characters DEC HEX CP 1252 ASCII Alternate Extended PS2 Scan Code 128 80 Ç up arrow 0x48 129 81 ü down arrow 0x50 130 82 é right arrow 0x4B 131 83 ƒ â left arrow 0x4D 132 84 ä Insert 0x52 133 85 à Delete 0x53 134 86 å Home 0x47 135 87 ç End 0x4F 136 88 ˆ ê Page Up 0x49 1...

Page 192: ...t 0x36 165 A5 Ñ Print Screen n a 166 A6 ª Tab 0x0F 167 A7 º Shift Tab 0x8F 168 A8 Enter 0x1C 169 A9 Esc 0x01 170 AA ª Alt Make 0x36 171 AB Alt Break 0xB6 172 AC Control Make 0x1D 173 AD Control Break 0x9D 174 AE Alt Sequence with 1 Character 0x36 175 AF Ctrl Sequence with 1 Character 0x1D 176 B0 177 B1 178 B2 179 B3 180 B4 181 B5 µ 182 B6 183 B7 184 B8 185 B9 186 BA º 187 BB 188 BC 189 BD 190 BE 1...

Page 193: ...21 DD Ý 222 DE Þ 223 DF ß 224 E0 à α 225 E1 á ß 226 E2 â Γ 227 E3 ã π 228 E4 ä Σ 229 E5 å σ 230 E6 æ µ 231 E7 ç τ 232 E8 è Φ 233 E9 é Θ 234 EA ê Ω 235 EB ë δ 236 EC ì 237 ED í φ 238 EE î ε 239 EF ï 240 F0 ð 241 F1 ñ 242 F2 ò 243 F3 ó 244 F4 ô 245 F5 õ 246 F6 ö 247 F7 248 F8 ø 249 F9 ù 250 FA ú 251 FB û Extended ASCII Characters Continued DEC HEX CP 1252 ASCII Alternate Extended PS2 Scan Code ...

Page 194: ...c National Character Replacement ISO IEC 2022 n a 2 default Binary Code page n a n a 3 Default Automatic National Character replacement will select the below Honeywell Code Page options for Code128 Code 39 and Code 93 United States ISO IEC 646 06 0 1 Canada ISO IEC 646 121 54 95 Canada ISO IEC 646 122 18 96 Japan ISO IEC 646 14 28 98 China ISO IEC 646 57 92 99 Great Britain UK ISO IEC 646 04 7 87 ...

Page 195: ...28 98 CN 92 99 GB 7 87 FR 3 83 à ç µ é ù è DE 4 84 Ä Ö Ü ä ö ü ß CH 6 86 ù à é ç ê î ô ä ö ü û SE FI 2 82 É Ä Ö Å Ü é ä ö å ü DK 8 88 Æ Ø Å æ ø å NO 9 94 Æ Ø Å æ ø å IE 73 97 Ó É Í Ú Á ó é í ú á IT 5 85 ç é ù à ò è ì PT 13 92 Ã Ç Õ ã ç õ ES 10 90 Ñ ñ ç ES 51 91 Ñ Ç ñ ç COUNTRY Country Keyboard Honeywell CodePage ISO IEC 646 National Character Replacements ...

Page 196: ...54 59 3A 3B 3C 3E 3F 38 40 3D 5A 5F 64 5B 60 65 5C 61 66 5D 62 67 63 68 69 6A 6C 104 Key U S Style Keyboard 6E 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 4B 50 55 4C 51 56 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1E 2C 1F 20 21 22 23 24 25 26 27 28 29 2B 39 2E 2F 30 31 32 33 34 35 36 37 53 4F 54 59 3A 3B 3C 3E 3F 38 40 3D 5A 5F 64 5B 60 65 5C 61 66 5D 62 6...

Page 197: ...ymbols UPC A 0 123456 7890 Interleaved 2 of 5 Code 128 EAN 13 Code 39 Codabar 1234567890 Code 128 9 780330 290951 BC321 A13579B Code 93 123456 9 Code 2 of 5 123456 6543210 RSS 14 01 00123456789012 Matrix 2 of 5 ...

Page 198: ...Sample Symbols Aztec MaxiCode Micro PDF417 Package Label Test Message Test Message PDF417 Postnet Code 49 Car Registration Zip Code 1234567890 Data Matrix QR Code Test Symbol Numbers ...

Page 199: ...Programming Chart 0 1 2 3 4 5 6 7 8 9 ...

Page 200: ...Programming Chart Note If you make an error while scanning the letters or digits before scanning Save scan Discard scan the correct letters or digits and Save again A B C D E F Save Discard Reset ...

Page 201: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com 3330 UG Rev A 10 15 ...

Reviews: