VR8215S,T TRADELINE DIRECT IGNITION COMBINATION GAS CONTROLS
34-00006EF—01
2
Table 4. Natural-LP Gas Conversion Kits.
PLANNING THE
INSTALLATION
WARNING
Fire or Explosion Hazard.
Can cause property damage, severe injury,
or death.
Follow these warnings exactly:
1. Plan the installation as outlined below.
2. Plan for frequent maintenance as described in
the Maintenance section.
Heavy demands are made on the controls when direct
ignition systems are used on central heating equipment in
barns, greenhouses, and commercial properties and on
heating appliances such as commercial cookers,
agricultural equipment, industrial heating equipment and
pool heaters.
Special steps may be required to prevent nuisance
shutdowns and control failure due to frequent cycling,
severe environmental conditions related to moisture,
corrosive chemicals, dust or excessive heat. These
applications require Honeywell Engineering review;
contact your Honeywell Sales Representative for
assistance.
Review the following conditions that can apply to your
specific installation and follow the precautions suggested.
Frequent Cycling
This control is designed for use on appliances that
typically cycle three to four times an hour only during the
heating season. In year-around applications with greater
cycling rates, the control can wear out more quickly.
Perform a monthly checkout.
Water or Steam Cleaning
If a control gets wet, replace it. If the appliance is likely to
be cleaned with water or steam, protect (cover) the control
and wiring from water or steam flow. Mount the control
high enough above the bottom of the cabinet so it does
not get wet during normal cleaning procedures.
High Humidity or Dripping Water
Dripping water can cause the control to fail. Never
install an appliance where water can drip on the control.
In addition, high ambient humidity can cause the control
to corrode and fail. If the appliance is in a humid
atmosphere, make sure air circulation around the control
is adequate to prevent condensation. Also, regularly
check out the system.
Corrosive Chemicals
Corrosive chemicals can attack the control, eventually
causing a failure. If chemicals are used for routine
cleaning, avoid contact with the control. Where chemicals
are suspended in air, as in some industrial or agricultural
applications, protect the control with an enclosure.
Model Number Suffix Letter
Kit to Convert Natural Gas to LP
Kit to Convert LP to Natural Gas
S, T
396221
396222
Table 5. Replacement Part Cross-Reference.
Trade Replacements
(Double-Check Specifications
Before Replacement)
Competitive Replacement
Universal
Service Part
Direct Service
Part Replacement
Honeywell
White-Rogers Robertshaw
VR8215
VR8215S1503
VR8205S2262, VR8205S2270, VR8205S2296,
VR8205S2338, VR8205S2353, VR8205S2361,
VR8205S2379, VR8205S2395, VR8205S2437,
VR8205S2858, VR8205S2882, VR8205S5802,
VR8205S5828, VR8205S5836, VR8205S5844,
VR8215S1222, VR8215S1263, VR8215S5207,
VR8215S5215, VR8205A2008, VR8205A2016,
VR8205A2024, VR8205A2065, VR8205A2081,
VR8205A2131, VR8205A2263, VR8205A2800,
VR8205M1080, VR8205M1106, VR8205M1122,
VR8205M1130, VR8205M1148, VR8205M1155,
VR8205M1163, VR8205M2310, VR8205M2401,
VR8205M2476, VR8205M2484, VR8205M2831,
VR8205M2864, VR8205M2872, VR8205M2880,
VR8205M5024, VR8205M5032
36G22-214,
36J22-214,
36G22-207
VR8215T1502
VR8205H1003, VR8205H1011, VR8205H2605,
VR8205H2621, VR8205K1157, VR8205K1173,
VR8205K2247, VR8205K2593, VR8205K2619,
VR8205T5801, VR8215T1205, VR8215T1239,
VR8215T5206, VR8215T5214