VP526 Three-Way High Pressure Water Valve
Three-way pneumatic mixing valve provides proportional control
of hot and/or cold water in unit air conditioners and fan coil
systems. Replacement devices are available for Johnson, Powers,
Robertshaw, Barber-Colman, and older Honeywell devices.
•
Small size permits installation where space is limited.
•
Direct-acting, rolling diaphragm actuator with integral high
temperature plastic air connector for 1/4 in. (6-mm) O.D. plastic
tubing.
•
Spring loaded, self-adjusting Buna-N “V”-ring packing replaceable.
•
Brass seats (integral lower, removable upper) and contoured plug
provide metal-to-metal seating.
•
Stainless steel stem.
•
Linear and constant total flow throughout full plug travel.
Dimensions in inches (millimeters)
VP526 Typical Piping Diagram
Close-off Ratings for the VP526
Valve Type:
Unitary
Body Pattern:
Three-way Mixing
Body Pressure:
250 psi (1724 kPa)
Air Connections:
Push on for 1/4 in. O.D. plastic tubing
Valve Action:
Proportional Normally Open Ports B to AB
Controlled Medium:
Water
Type of End Connection:
45 deg. SAE flare
Operating Humidity Range (% RH):
5 to 95% RH
Temperature Range:
35 F to 250 F (2 C to 121 C)
Maximum Safe Actuator Diaphragm Temperature:
230 F (110 C)
Maximum Diaphragm Pressure:
29 psi (200 kPa)
CLEARANCE REQUIRED
TO SERVICE VALVE
1-1/2 (38)
MIN.
2-1/4 (57) DIA.
AIR CONNECTION
FOR 1/4 IN. (6 MM)
O.D. PLASTIC TUBING
MINIMUM FOR
REMOVAL OF VALVE
1-5/8
(41)
A
D
E
B
C
F
G
H
A
D
E
B
C
F
G
H
1
1
VALVE
SIZE
COPPER
TUBING
(O.D.)
IN. (MM)
3/8
1/2
1/2
5/8
3-1/16
(78)
3-3/8
(85)
7/8
(22)
1-3/16
(30)
13/16
(20)
7/8
(22)
1-1/2
(38)
1-3/4
(44)
3/8
(10)
7/16
(11)
1-1/2
(38)
1-11/16
(43)
3
(76)
3-7/16
(87)
5-3/4
(146)
6-1/4
(159)
ALLOW 1-1/2 IN. (38 MM) MINIMUM CLEARANCE FOR REMOVING
ACTUATOR. ALLOW 2-1/2 IN. (63 MM) TO FACILITATE STRAIGHT ON
TUBING. IF CLEARANCE IS LESS THAN 2-1/2 IN. (63 MM), USE
AN ELBOW.
M18807A
A
AB
B
SUPPLY
RETURN
CONTROL AIR
VP526A
N. O. PORTS
B TO AB
C2726
COIL
C493-1
CLOSE OFF PRESSURE RATING, PSI (kPa)
(DIFFERENTIAL PRESSURE BETWEEN
SUPPLY AND RETURN LINES)
0
10
(69)
20
(138)
30
(207)
40
(276)
50
(345)
60
(414)
70
(483)
ALL C
V
s
5
6
7
8
9
10
11
12
13
14
10
11
12
13
14
15
16
17
18
—
2
1
0
—
—
—
—
—
—
—
3
2
1
0
—
—
—
—
—
—
11
12
13
14
15
16
17
18
—
—
8
7
6
5
4
3
2
1
0
—
B
A
B
A
B
A
CONTROL
AIR PRESSURE ON
ACTUA
T
OR, PSI (kPa)
PORTS
2-5 PSI SPRING
(14-34 kPa)
3-10 PSI SPRING
(21-69 kPa)
8-1
1 PSI SPRING
(55-76 kPa)