background image

A - 1

A

Reference Charts

Symbology Charts

Note: “m” represents the AIM modifier character.  Refer to International Technical Specification, Symbology Identifiers, for AIM 

modifier character details.

Prefix/Suffix entries for specific symbologies override the universal (All Symbologies, 99) entry.

Refer to 

Data Editing

beginning on page 5-1 an

Data Formatting

beginning on page 6-1 for information about using Code ID 

and AIM ID.

Linear Symbologies

AIM

Honeywell

Symbology

ID

Possible  modifiers 
(

m

)

ID

Hex

All Symbologies

99

Codabar

]F

m

0-1

a

61

Code 11

]H3

h

68

Code 128

]C

m

0, 1, 2, 4

j

6A

Code 32 Pharmaceutical (PARAF)

]X0

<

3C

Code 39 (supports Full ASCII mode)

]A

m

0, 1, 3, 4, 5, 7

b

62

TCIF Linked Code 39 (TLC39)

]L2

T

54

Code 93 and 93i

]G

m

0-9, A-Z, 
a-m

i

69

EAN

]E

m

0, 1, 3, 4

d

64

EAN-13 (including Bookland EAN)

]E0

d

64

EAN-13 with Add-On

]E3

d

64

EAN-13 with Extended Coupon Code

]E3

d

64

EAN-8

]E4

D

44

EAN-8 with Add-On

]E3

D

44

GS1

GS1 DataBar

]e

m

0

y

79

GS1 DataBar Limited

]e

m

{ 7B

GS1 DataBar Expanded

]e

m

}

7D

GS1-128 ]C1

I

49

2 of 5

China Post (Hong Kong 2 of 5)

]X0

Q

51

Interleaved 2 of 5

]I

m

0, 1, 3

e

65

Matrix 2 of 5

]X0

m

6D

NEC 2 of 5

]X0

Y

59

Straight 2 of 5 IATA

]R

m

0, 1, 3

f

66

Straight 2 of 5 Industrial 

]S0

f

66

MSI

]M

m

0, 1

g

67

Telepen

]B

m

t

74

UPC

0, 1, 2, 3, 8, 9, A, B, C

Summary of Contents for Voyager 1602g

Page 1: ...Voyager 1602g Wireless Area Imaging Pocket Scanner User s Guide ...

Page 2: ...e of software and or hardware to achieve intended results This document contains proprietary information that is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated into another language without the prior written consent of HII Copyright 2015 Honeywell International Inc All rights reserved Web Address www honeywellaidc com Microsoft W...

Page 3: ...ry Layout 2 1 Keyboard Style 2 8 Keyboard Conversion 2 9 Control Character Output 2 10 Keyboard Modifiers 2 10 Programming an Interface for an Access Point 2 12 Keyboard Wedge 2 12 Laptop Direct Connect 2 12 RS232 Serial Port 2 12 RS485 2 13 USB IBM SurePos 2 14 USB PC or Macintosh Keyboard 2 14 USB HID 2 15 USB Serial 2 15 Remote MasterMind for USB 2 15 Gilbarco Terminal Default Settings 2 16 Hon...

Page 4: ... 4 RF Radio Frequency Module Operation 3 4 System Conditions 3 4 Scanner Is Out of Range 3 4 Scanner Is Moved Back Into Range 3 4 Out of Range and Back into Range with Batch Mode On 3 4 About the Battery 3 5 Charging Information 3 5 Battery Recommendations 3 5 Proper Disposal of the Battery 3 5 Beeper and LED Sequences and Meaning 3 5 Scan LED Sequences and Meaning 3 6 Low Battery Indicator 3 6 Re...

Page 5: ...e Last Code 3 20 Clear All Codes 3 20 Transmit Records to Host 3 20 Batch Mode Transmit Delay 3 20 Host Acknowledgment 3 21 Host ACK Timeout 3 22 Chapter 4 Input Output Settings Programmable Button 4 1 Virtual Keyboard 4 1 Battery Charge Status 4 2 Flashlight Mode 4 2 Bluetooth Pair Unpair 4 3 Disable Programmable Button 4 3 Power Up Beeper 4 4 Beep on BEL Character 4 4 Trigger Click 4 4 Good Read...

Page 6: ...15 Preferred Symbology Default 4 15 Output Sequence Overview 4 15 Output Sequence Editor 4 15 To Add an Output Sequence 4 15 Other Programming Selections 4 16 Output Sequence Editor 4 17 Partial Sequence 4 17 Require Output Sequence 4 17 Multiple Symbols 4 18 No Read 4 18 Video Reverse 4 19 Working Orientation 4 19 Chapter 5 Data Editing Prefix Suffix Overview 5 1 To Add a Prefix or Suffix 5 1 To ...

Page 7: ...dabar 7 2 Codabar Concatenation 7 3 Code 39 7 4 Code 32 Pharmaceutical PARAF 7 5 Full ASCII 7 6 Code 39 Code Page 7 6 Interleaved 2 of 5 7 7 NEC 2 of 5 7 8 Code 93 7 9 Code 93 Code Page 7 10 Straight 2 of 5 Industrial three bar start stop 7 11 Straight 2 of 5 IATA two bar start stop 7 12 Matrix 2 of 5 7 13 Code 11 7 14 Code 128 7 15 ISBT 128 Concatenation 7 15 Code 128 Code Page 7 16 GS1 128 7 17 ...

Page 8: ...D 7 44 Single 2D Postal Codes 7 44 Combination 2D Postal Codes 7 45 Postal Codes Linear 7 48 China Post Hong Kong 2 of 5 7 48 Korea Post 7 49 Chapter 8 Interface Keys Keyboard Function Relationships 8 1 Supported Interface Keys 8 2 Chapter 9 Utilities To Add a Test Code I D Prefix to All Symbologies 9 1 Show Decoder Revision 9 1 Show Scan Driver Revision 9 1 Show Software Revision 9 1 Show Data Fo...

Page 9: ...apter 12 Maintenance and Troubleshooting Repairs 12 1 Maintenance 12 1 Cleaning the Scanner 12 1 Cleaning the Window 12 1 Inspecting Cords and Connectors 12 1 Replacing a Battery 12 2 Troubleshooting 12 3 Appendix A Reference Charts Symbology Charts A 1 Linear Symbologies A 1 2D Symbologies A 2 Postal Symbologies A 2 ASCII Conversion Chart Code Page 1252 A 3 Lower ASCII Reference Table A 4 ISO 202...

Page 10: ...viii ...

Page 11: ...ain warranty or non warranty service please visit www honeywellaidc com and select Support Contact Service and Repair to see your region s instructions on how to obtain a Return Material Authorization number RMA You should do this prior to returning the product Limited Warranty Refer to www honeywellaidc com warranty_information for your product s warranty information Send Feedback Your feedback i...

Page 12: ...x ...

Page 13: ...r codes in this guide An asterisk next to an option indicates the default setting Unpacking Your Device After you open the shipping carton containing the product take the following steps Check for damage during shipment Report damage immediately to the carrier who delivered the carton Make sure the items in the carton match your order Save the shipping container for later storage or shipping Charg...

Page 14: ... 3 for further information Battery Charge Indicator When the battery is charging the small LED at the top left of the scanner flashes orange When the battery is fully charged this LED is solid green Refer to Scan LED Sequences and Meaning page 3 6 and Low Battery Indicator page 3 6 for the complete list of LED indications To use your scanner with a Honeywell Access Point AP01 XXXBT refer to Host A...

Page 15: ...atically pair with the scanner If your device automatically pairs with the scanner it displays a successful pairing message and you do not need to continue to the next step 4 If your personal computer laptop or tablet does not automatically pair with the scanner a PIN is displayed This PIN must be scanned within 60 seconds You must quickly scan Bluetooth PIN Code below then scan the numeric bar co...

Page 16: ... begin scanning bar codes Verify the scanner operation by scanning a bar code from the Sample Symbols in the back of this manual Reading Techniques The Voyager 1602g has a large scan button just forward of a smaller programmable button See Programmable Button on page 4 1 for further information about the programmable button 6 7 8 9 Save Scan button ...

Page 17: ...nner If you want to restrict the ability to scan menu codes you can use the Menu Bar Code Security settings Contact the nearest technical sup port office see Technical Assistance on page ix for further information Setting Custom Defaults You have the ability to create a set of menu commands as your own custom defaults To do so scan the Set Custom Defaults bar code below before scanning the menu co...

Page 18: ...he custom default settings restored to your scanner scan the Activate Custom Defaults bar code below This is the recommended default bar code for most users It resets the scanner to the custom default settings If there are no custom defaults it will reset the scanner to the factory default settings Any settings that have not been specified through the custom defaults will be defaulted to the facto...

Page 19: ... beginning on page 2 23 Keyboard Country Layout If your interface is USB Keyboard or Keyboard Wedge through an Access Point or a Bluetooth Keyboard your keyboard layout default is a US keyboard To change this layout refer to the chart below for your keyboard country Scan the appropriate bar code below to change the layout By default national character replacements are used for the following charac...

Page 20: ...2 2 Keyboard Countries Continued Brazil MS Bulgaria Cyrillic Bulgaria Latin Canada French legacy Canada French Canada Multilingual Croatia Czech Czech Programmers Czech QWERTY Czech QWERTZ ...

Page 21: ...2 3 Keyboard Countries Continued Denmark Dutch Netherlands Estonia Faroese Finland France Gaelic Germany Greek Greek 220 Latin Greek 220 ...

Page 22: ...2 4 Keyboard Countries Continued Greek 319 Latin Greek 319 Greek Latin Greek MS Greek Polytonic Hebrew Hungarian 101 key Hungary Iceland Irish Italian 142 ...

Page 23: ...2 5 Keyboard Countries Continued Italy Japan ASCII Kazakh Kyrgyz Cyrillic Latin America Latvia Latvia QWERTY Lithuania Lithuania IBM Macedonia Malta ...

Page 24: ...2 6 Keyboard Countries Continued Mongolian Cyrillic Norway Poland Polish 214 Polish Programmers Portugal Romania Russia Russian MS Russian Typewriter SCS ...

Page 25: ...2 7 Keyboard Countries Continued Serbia Cyrillic Serbia Latin Slovakia Slovakia QWERTY Slovakia QWERTZ Slovenia Spain Spanish variation Sweden Switzerland French Switzerland German ...

Page 26: ...eyboard Conversion settings they will override any of the following Keyboard Style settings Default Regular Keyboard Countries Continued Tatar Turkey F Turkey Q Ukrainian United Kingdom United States Dvorak United States Dvorak left United Stated Dvorak right United States International Uzbek Cyrillic ...

Page 27: ... but uses the NumLock key to retrieve the current state of the Caps Lock Emulate External Keyboard should be scanned if you do not have an external keyboard IBM AT or equivalent Note After scanning the Emulate External Keyboard bar code you must power cycle the host system Keyboard Conversion Alphabetic keyboard characters can be forced to be all upper case or all lowercase So if you have the foll...

Page 28: ...ode Control X Control ASCII Mode On The scanner sends key combinations for ASCII control characters for values 00 1F Windows is the preferred mode All keyboard country codes are supported DOS mode is a legacy mode and it does not sup port all keyboard country codes New users should use the Windows mode Refer to Keyboard Function Relationships page 8 1 for CTRL X Values Windows Mode Prefix Suffix O...

Page 29: ...om a numeric keypad Default Off Automatic Direct Connect Mode This selection can be used if you have an IBM AT style terminal and the system is dropping characters Default Off Control X Mode Off DOS Mode Control X Mode On Windows Mode Prefix Suffix Off Turbo Mode On Turbo Mode Off Numeric Keypad Mode On Numeric Keypad Mode Off Automatic Direct Connect Mode On Automatic Direct Connect Mode Off ...

Page 30: ...top Direct Connect bar code allows operation of the scanner in parallel with the inte gral keyboard The following Laptop Direct Connect bar code also programs a carriage return CR suffix and turns on Emulate External Keyboard page 2 9 Power cycle the host after scanning this bar code This interface is only appropri ate for an Access Point RS232 Serial Port The RS232 Interface bar code is used when...

Page 31: ...683 Port 9 HHBCR 2 Interface RS485 Packet Mode The following selection allows you to break up large bar code data into smaller packets on an IBM POS terminal To break up large bar codes into small packets scan the Packet Mode On bar code below Scan the Packet Mode Off bar code if you want large bar code data to be sent to the host in a single chunk Default Packet Mode Off Symbology Suffix Symbolog...

Page 32: ...r scanning one of these codes you must power cycle the cash register Each bar code above also programs the following suffixes for each symbology USB PC or Macintosh Keyboard Scan one of the following codes to program the scanner for USB PC Keyboard or USB Macintosh Keyboard then power cycle the host Scanning these codes also adds a CR suffix This interface is only appropriate for an Access Point S...

Page 33: ...The driver will use the next available COM Port num ber Apple Macintosh computers recognize the scanner as a USB CDC class device and automatically use a class driver Note No extra configuration e g baud rate is necessary CTS RTS Emulation ACK NAK Mode Remote MasterMind for USB When using a USB interface you may wish to configure your scanner to communicate with Remote MasterMind Scanner Managemen...

Page 34: ... following Plug and Play code to program the scanner for a Honeywell bioptic scanner auxiliary port configuration then power cycle the host This bar code sets the baud rate to 38400 bps and the data format to 8 data bits no parity 1 stop bit Datalogic Magellan Aux Port Configuration This interface is only appropriate for an Access Point Scan the following Plug and Play code to program the scanner ...

Page 35: ...o parity 1 stop bit Wincor Nixdorf Beetle Terminal Default Settings This interface is only appropriate for an Access Point Scan the following Plug and Play code to program the scanner for a Wincor Nixdorf Beetle terminal then power cycle the host The following prefixes are programmed for each symbology Symbology Prefix Symbology Prefix UPC A A Interleaved 2 of 5 b UPC E E0 Code 128 f Code 32 Pharm...

Page 36: ...d the data format to 8 data bits odd parity 1 stop bit The following prefixes are programmed for each symbology RS232 Modifiers The following RS232 settings should only be used when connecting through an Access Point RS232 Baud Rate Baud Rate sends the data from the scanner to the terminal at the specified rate The host terminal must be set for the same baud rate as the scanner Default 115 200 Win...

Page 37: ... bits For applications that require use of the full ASCII set select 8 data bits per character Default 8 Stop Bits sets the stop bits at 1 or 2 Default 1 Parity provides a means of checking character bit patterns for validity Default None 38400 57 600 115 200 7 Data 1 Stop Parity Even 7 Data 1 Stop Parity None 7 Data 1 Stop Parity Odd 7 Data 2 Stop Parity Even 7 Data 2 Stop Parity None 7 Data 2 St...

Page 38: ...ission from the scanner using software commands from the host device When RTS CTS is turned Off no data flow control is used Flow Control No Timeout The scanner asserts RTS when it has data to send and will wait indefinitely for CTS to be asserted by the host Two Direction Flow Control The scanner asserts RTS when it is OK for the host to transmit The host asserts CTS when it is OK for the device ...

Page 39: ...the scanner data trans mission stops To resume transmission the host sends the XON character DC1 hex 11 Data transmission contin ues where it left off when XOFF was sent Default XON XOFF Off ACK NAK After transmitting data the scanner waits for an ACK character hex 06 or a NAK character hex 15 response from the host If ACK is received the communications cycle is completed and the scanner looks for...

Page 40: ... scanner s format so it is compatible with a bioptic scanner Default Packet Mode Off Scanner Bioptic ACK NAK Mode Bioptic ACK NAK On must be scanned so the scanner will wait for an ACK or NAK from a bioptic scanner after each packet is sent The Scanner Bioptic ACK NAK Timeout below controls how long the scanner will wait for a response Default Bioptic ACK NAK Off Scanner Bioptic ACK NAK Timeout Th...

Page 41: ...nication Cordless Scanner Note Once the communication is set to USB Corded Scanner the VG1602g can only communicate with the host via a USB interface cable Corded USB PC or Macintosh Keyboard Scan one of the following codes to program the corded scanner for a USB Keyboard either PC or Macintosh then power cycle the host Corded USB HID POS Scan the following code to program the corded scanner for U...

Page 42: ... Honeywell website www honeywellaidc com The driver will use the next available COM Port number Apple Macintosh computers recog nize the scanner as a USB CDC class device and automatically use a class driver Note No extra configuration e g baud rate is necessary Corded CTS RTS Emulation Corded ACK NAK Mode Corded USB Serial Corded CTS RTS Emulation On Corded CTS RTS Emulation Off Corded ACK NAK Mo...

Page 43: ...verable state Once the scanner searches for and connects with a Bluetooth host the scanner stores the connection to the host device address and switches virtual COM ports This allows the scanner to automatically relink to the host if the connection is lost PDAs Mobility Systems Devices You may also use the scanner with a PDA or a Honeywell Mobility Systems device Scan the bar code below and follow...

Page 44: ...continuous transmissions that could interfere with other users of the ISM band the number of attempts to connect is limited by this setting After the maximum number of attempts is reached the scanner will not attempt to reconnect to a host Pressing the scan button scanning a host linking bar code or pairing the scanner with a host resets the attempt count and the scanner will again try to link Eve...

Page 45: ...e scanner repeatedly attempts to connect to the host Each attempt consists of approximately 5 seconds of active time followed by 3 seconds of idle time After one hour the scanner powers off and batch mode data is lost Maximum Link Attempts set to 15 Other values at default setting When the scanner goes out of range 15 attempts are made to link to the host Each attempt consists of approximately 5 s...

Page 46: ...ommunication range between the scanner and host depending on the environ ment is 33 feet 10m See Flexible Power Management page 3 10 for information about controlling this range System Conditions The components of the wireless system interact in specific ways as you move a scanner out of range bring a scanner back in range or swap scanners between two hosts The following information explains the w...

Page 47: ...er Support on page ix for additional information Caution Use only Honeywell Li ion battery packs part number 3H21 00000112 or 163480 0001 rated 3 7 Vdc 2 77Whr in this device Use of any non Honeywell battery may result in damage not covered by the warranty Safety Precautions for Lithium Batteries Do not place batteries in fire or heat the batteries Do not store batteries near fire or other high te...

Page 48: ...low to generate a report for the connected scanners The report indicates the port work group scanner name and address To assign a name to your scanner refer to Menu Command Syntax page 10 1 LED Indication Beeper Indication Cause Normal Operation Red flash None Battery low Green flash 1 beep Successful scan Red blinking Razz or error tone Failed communication Blue off None Bluetooth connection has ...

Page 49: ...being linked to that host To use a different scanner you need to unlink the original scanner by scanning the Unlink Scanner bar code See Unlinking the Scanner below Open Link Mode Single Scanner When in Open Link Single Scanner Mode each time a scanner is paired with a host the scanner becomes linked to the host and the old scanner is unlinked Unlinking the Scanner If a host has a scanner linked t...

Page 50: ...00 seconds by scanning digits on the Programming Chart inside the back cover then scanning Save Default 0 sec no alarm Note If you are out of range when you scan a bar code you will receive an error tone even if you do not have the alarm set because the data could not be communicated to the host Alarm Sound Type Change the alarm type by scanning the following bar code and then scanning a digit 0 7...

Page 51: ...canner power time out bar code to change the time out duration in seconds Note Scanning zero 0 is the equivalent of setting no time out If there are no scan button presses during the timer interval the scanner goes into power down mode Whenever the scan but ton is pressed the timer is reset The scanner will not go into power down mode when the battery is charging Default 3600 seconds Scanner Idle ...

Page 52: ...Power 35 Medium Low Power 5 or Low Power 1 Default Full Power Multiple Scanner Operation Note Multiple Scanner Operation Mode allows you to link up to 7 scanners to one Access Point You cannot join an 8th scanner until you unlink one of the 7 scanners or take a scanner out of range To put the scanner in multiple scanner mode scan the bar code below Once you scan this bar code the scanner is unlink...

Page 53: ...change the names of additional scanners link them one at a time and repeat the ScannerName BT_N AMNewName command for each scanner To rename scanners with sequential numeric names scan the bar codes below Scan the Reset code after each name change and wait for the scanner to relink to the host before scanning a bar code to rename the next scanner You may also scan the Scanner Name bar code below a...

Page 54: ...s in that particular work group Honeywell s online configuration tool EZConfig Scanning page 9 2 makes it easy for you to program your system for use with multiple scanners and multiple work groups The scanner keeps a copy of the menu settings it is using Whenever the scanner is connected or reconnected to a host the scanner is updated with the latest settings from the host for its work group The ...

Page 55: ...t Settings bar code below If there are no custom defaults it will reset the work groups to the factory defaults See Setting Custom Defaults on page 1 5 for further information about custom defaults Note Scanning this bar code also causes both the scanner and the host to perform a reset and become unlinked You must relink pair the scanner to the host See Bluetooth Settings page 3 1 for additional i...

Page 56: ...oint If your scanner has been connected directly to an iPad smart phone or laptop you must disconnect it in order to commu nicate with an Access Point Scan the Bluetooth HID Keyboard Disconnect bar code to unlink the scanner from the cur rently linked host Scan the linking bar code on the Access Point to relink the scanner Replacing a Linked Scanner If you need to replace a broken or lost scanner ...

Page 57: ...scanners when the button is pressed The blue LED on the Access Point will remain lit to indicate that Paging Mode is off This light will go out when the button is pressed then back on when it s released Default Paging Mode On Paging Pitch When you press the Page button on the Access Point the scanners associated with that Access Point will begin beeping You can set the pitch of the paging beep for...

Page 58: ...r s buffer space is full any bar codes scanned generate an error tone In order to scan bar codes again the scanner must be moved back into range of the Access Point so data can be transmitted Inventory Batch Mode stores bar code data whether or not you are in range of the Access Point To transmit the stored data to the Access Point scan Transmit Inventory Records page 3 20 When the scanner s buffe...

Page 59: ...torage The scanner will not power down while it contains data that has not been transmitted to the Access Point even if it reaches a power down timeout However if the scanner runs out of battery power it will power down and the data will be lost Default Flash Storage Batch Mode Quantity When in Batch Mode you may wish to transmit the number of multiple bar codes scanned rather than a single bar co...

Page 60: ... s bar code 2 Scan the quantity 5 bar code Example Add a quantity of 1 500 for the last item scanned 1 Scan the item s bar code 2 Scan the quantity 1 bar code 3 Scan the quantity 5 bar code 4 Scan the quantity 0 bar code 5 Scan the quantity 0 bar code Example Change a quantity of 103 to 10 To correct an incorrect quantity scan the quantity 0 bar code to replace the incorrect digits then scan the c...

Page 61: ...er you want that data sent as FIFO first in first out or LIFO last in first out Default Batch Mode FIFO Total Records If you wish to output the total number of bar codes scanned when in Batch Mode scan Total Records 4 5 6 7 8 9 Batch Mode FIFO Batch Mode LIFO Total Records ...

Page 62: ...de Transmit Delay Sometimes when accumulated scans are sent to the host system the transmission of those scans is too fast for the appli cation to process To program a transmit delay between accumulated scans scan one of the following delays Default Off Note In most cases a short 250 ms milliseconds delay is ideal however longer delays may be programmed Contact Technical Support page ix for additi...

Page 63: ...ESC is a 1B in hex A typical command string is y ESC x where y is the application work group number ESC x is the escape command and the comma is the terminator which is required When y is not specified the command is sent to the default Application Work Group 0 Example Commands may be strung together to create custom response sequences An example of a command string is listed below 0 ESC 4 ESC 5 E...

Page 64: ...ouble beeps to indicate a successful menu change was made ESC b Razz or error tone to indicate a menu change was unsuccessful ESC 1 The green LED illuminates for 135 milliseconds followed by a pause ESC 2 The green LED illuminates for 2 seconds followed by a pause ESC 3 The green LED illuminates for 5 seconds followed by a pause ESC 4 Emits a beep at a low pitch ESC 5 Emits a beep at a medium pitc...

Page 65: ...ese selections to occur after a short button press and another selection to occur after a long button press The scanner emits a short beep to let you know when the button has been held down long enough Virtual Keyboard Once your scanner has been connected directly to an Apple iPad smart phone or laptop you can toggle the virtual key board on the host with either a short or a long press of the prog...

Page 66: ... bar codes below Pressing the programmable button short or long press turns the flashlight on Pressing the scan button turns it back off Battery Charge Status On Short Press Battery Charge Status On Long Press LED Indicator Battery Charge Status Orange flash Battery is charging Orange blink once Battery is 25 49 Orange blink twice Battery is 50 74 Orange blink three times Battery is 75 99 Green on...

Page 67: ...ess of the programmable button Disable Programmable Button To disable the programmable button scan one or both of the bar codes below Default Disable Short and Long Press Bluetooth Pair Unpair On Short Press Bluetooth Pair Unpair On Long Press LED Indicator Beeper Indicator Bluetooth Status Blue off None Bluetooth connection has not been established Blue flash None Scanner is attempting to pair wi...

Page 68: ...bar code below the scanner will beep every time a BEL character is received from the host Default Beep on BEL Off Trigger Click To hear an audible click every time the scanner button is pressed scan the Trigger Click On bar code below Scan the Trigger Click Off code if you don t wish to hear the click This feature has no effect on serial or automatic triggering Default Trigger Click Off Power Up B...

Page 69: ...rror and menu beeps are still audible Default Beeper Good Read On Beeper Volume Good Read The beeper volume codes modify the volume of the beep the scanner emits on a good read Default High Beeper Pitch Good Read The beeper pitch codes modify the pitch frequency of the beep the scanner emits on a good read Default Medium Beeper Good Read Off Beeper Good Read On Low Medium High Off Low 1600 Hz Medi...

Page 70: ...z Beeper Duration Good Read The beeper duration codes modify the length of the beep the scanner emits on a good read Default Normal LED Good Read The LED indicator can be programmed On or Off in response to a good read Default On High 4200 Hz Razz 250 Hz Medium 3250 Hz High 4200 Hz Normal Beep Short Beep Short Beep LED Good Read On LED Good Read Off ...

Page 71: ...rogrammed from 1 9 For example if you program this option to have five error beeps there will be five error beeps and five LED flashes in response to an error To change the number of error beeps scan the bar code below and then scan a digit 1 9 bar code and the Save bar code on the Programming Chart inside the back cover of this manual Default 1 Good Read Delay This sets the minimum amount of time...

Page 72: ...nt The scanner can also be set to turn itself off after a specified time has elapsed see Read Time Out which follows Read Time Out Use this selection to set a time out in milliseconds of the scan button when using serial commands to trigger the scanner Once the scanner has timed out you can activate the scanner either by pressing the scan button or using a serial trigger command After scanning the...

Page 73: ...ed to the host system The scanner remains on scanning and decoding bar codes but the bar code data is not transmitted until the scan button is pressed When CodeGate is Off bar code data is transmitted when it is decoded Default CodeGate Off Out of Stand Mobile Phone Read Mode When this mode is selected your scanner is optimized to read bar codes from mobile phone or other LED displays However the ...

Page 74: ...t Code Page 1252 page A 3 find the hex value that represents the character you want to use to trigger scanning Scan the following bar code then use the Programming Chart to read the alphanumeric combination that represents that ASCII character Scan Save to finish Default 12 DC2 End Character Activation After Good Read After a bar code is successfully detected and read from the scanner the illumina...

Page 75: ...racter you will send from the host to terminate scanning Default Off Deactivation Character This sets the character used to terminate scanning when using Character Deactivation Mode On the ASCII Conversion Chart Code Page 1252 page A 3 find the hex value that represents the character you want to use to terminate scanning Scan the following bar code then use the Programming Chart inside the back co...

Page 76: ...ring to narrow the scanner s field of view to make sure that when the scanner is hand held it reads only those bar codes intended by the user For instance if multiple codes are placed closely together centering will insure that only the desired codes are read Centering can be used in conjunction with Aimer Delay page 4 12 for the most error free operation in applications where multiple codes are s...

Page 77: ...ead It does not need to pass completely through the centering window Scan Centering On then scan one of the following bar codes to change the top bottom left or right of the centering window Then scan the percent you want to shift the centering window using digits on the inside back cover of this manual Scan Save Default Centering 40 for Top and Left 60 for Bottom and Right 0 Bar Code 1 Bar Code 2...

Page 78: ...expires before a high priority symbology is read the scanner will read any bar code in its view low priority or unspecified If there is no bar code in the scanner s view after the time out period expires then no data is reported Note A low priority symbol must be centered on the aiming pattern to be read Scan a bar code below to enable or disable Preferred Symbology Default Preferred Symbology Off...

Page 79: ...e you read the Default Sequence symbol Note To make Output Sequence Editor selections you ll need to know the code I D code length and character match es your application requires Use the Alphanumeric symbols inside back cover to read these options You must hold the scan button while reading each bar code in the sequence To Add an Output Sequence 1 Scan the Enter Sequence symbol see Require Output...

Page 80: ...art character match for Code 39 41h A FF termination string for first code 6A code identifier for Code 128 9999 code length that must match for Code 128 9999 all lengths 42 start character match for Code 128 42h B FF termination string for second code 69 code identifier for Code 93 9999 code length that must match for Code 93 9999 all lengths 43 start character match for Code 93 43h C FF terminati...

Page 81: ...a acquired to that point is a partial sequence Scan Discard Partial Sequence to discard partial sequences when the output sequence operation is terminated before completion Scan Transmit Partial Sequence to transmit partial sequences Any fields in the sequence where no data match occurred will be skipped in the output Require Output Sequence When an output sequence is Required all output data must...

Page 82: ...e scanner attempts to find and decode new symbols as long as the scan button is pressed When this programming selection is turned Off the scanner will only read the symbol closest to the aiming beam Default Off No Read With No Read turned On the scanner notifies you if a code cannot be read If using an EZConfig Scanning Tool Scan Data Window see page 9 3 an NR appears when a code cannot be read If...

Page 83: ...r Video Reverse and Standard Bar Codes in order to read menu bar codes Note Images downloaded from the unit are not reversed This is a setting for decoding only Working Orientation Some bar codes are direction sensitive For example KIX codes and OCR can misread when scanned sideways or upside down Use the working orientation settings if your direction sensitive codes will not usually be presented ...

Page 84: ...4 20 Upright Vertical Bottom to Top Upside Down Vertical Top to Bottom ...

Page 85: ...ymbologies the specific symbology ID value counts as an added prefix or suffix character The maximum size of a prefix or suffix configuration is 200 characters which includes header information To Add a Prefix or Suffix Step 1 Scan the Add Prefix or Add Suffix symbol page 5 2 Step 2 Determine the 2 digit Hex value from the Symbology Chart included in the Symbology Charts beginning on page A 1 for ...

Page 86: ...aracter from a symbology When you Clear All Prefixes Suffixes all the prefixes or suffixes for a symbology are deleted Step 1 Scan the Clear One Prefix or Clear One Suffix symbol Step 2 Determine the 2 digit Hex value from the Symbology Chart included in the Symbology Charts beginning on page A 1 for the symbology from which you want to clear the prefix or suffix Step 3 Scan the 2 digit hex value ...

Page 87: ...he transmission of each character of scanned data Scan the Intercharacter Delay bar code below then scan the number of 5ms delays and the Save bar code using the Programming Chart inside the back cover of this manual To remove this delay scan the Intercharacter Delay bar code then set the number of delays to 0 Scan the Save bar code using the Programming Chart inside the back cover of this manual ...

Page 88: ...s manual To remove this delay scan the Interfunction Delay bar code then set the number of delays to 0 Scan the Save bar code using the Programming Chart inside the back cover of this manual Intermessage Delay An intermessage delay of up to 5000 milliseconds in 5ms increments may be placed between each scan transmission Scan the Intermessage Delay bar code below then scan the number of 5ms delays ...

Page 89: ... data format the next data format if there is one will be used on the bar code data If there is no other data format the raw data is output If you have changed data format settings and wish to clear all formats and return to the factory defaults scan the Default Data Format code below Add a Data Format Step 1 Scan the Enter Data Format symbol page 6 2 Step 2 Select Primary Alternate Format Determi...

Page 90: ...g Selections Clear One Data Format This deletes one data format for one symbology If you are clearing the primary format scan 0 from the Programming Chart inside the back cover of this manual If you are clearing an alternate format scan 1 2 or 3 depending on the format you are clearing Scan the Terminal Type and Code I D see Symbology Charts on page A 1 and the bar code data length for the specifi...

Page 91: ...ue 00 99 for the number of characters and xx stands for the insert character s hex value for its ASCII code Refer to the ASCII Conversion Chart Code Page 1252 beginning on page A 3 for decimal hex and character codes F2 Example Send a number of characters Send the first 10 characters from the bar code above followed by a carriage return Command string F2100D F2 is the Send a number of characters c...

Page 92: ...0ABC CR Send all but the last characters E9 Include in the output message all but the last nn characters starting from the current cursor position The cursor is moved forward to one position past the last input message character included Syntax E9nn where nn stands for the numeric value 00 99 for the number of characters that will not be sent at the end of the message Insert a character multiple t...

Page 93: ...rs F6 Move the cursor back nn characters from current cursor position Syntax F6nn where nn is the numeric value 00 99 for the number of characters the cursor should be moved back Move the cursor to the beginning F7 Move the cursor to the first character in the input message Syntax F7 FE and F7 Example Manipulate bar codes that begin with a 1 Search for bar codes that begin with a 1 If a bar code m...

Page 94: ...s Search forward for a non matching character E6 Search the input message forward for the first non xx character from the current cursor position leaving the cursor pointing to the non xx character Syntax E6xx where xx stands for the search character s hex value for its ASCII code Refer to the ASCII Conversion Chart Code Page 1252 beginning on page A 3 for decimal hex and character codes E6 Exampl...

Page 95: ...suppress filter and clear all suppressed characters Syntax FC Replace characters E4 Replaces up to 15 characters in the output message without moving the cursor Replacement continues until the E5 command is encountered Syntax E4nnxx1xx2yy1yy2 zz1zz2 where nn is the total count of the number of characters in the list characters to be replaced plus replacement characters xx1 defines characters to be...

Page 96: ...k for a number command F1 is the Send all characters command 0D is the hex value for a CR If this bar code is read the next data format if there is one will be used on the data If there is no other format the format fails and the raw data is output as AB1234 If this bar code is read the data is output as 1234AB CR Check for non numeric character ED Check to make sure there is a non numeric ASCII c...

Page 97: ...at symbol the prefixes and suffixes are transmitted Data Format Required Keep Prefix Suffix Scanned data is modified according to your data format and prefixes and suffixes are transmitted Any data that does not match your data format requirements generates an error tone and the data in that bar code is not transmitted If you wish to process this type of bar code without generating an error tone s...

Page 98: ...h Error Tone On bar code Default Data Format Non Match Error Tone On Primary Alternate Data Formats You can save up to four data formats and switch between these formats Your primary data format is saved under 0 Your other three formats are saved under 1 2 and 3 To set your device to use one of these formats scan one of the bar codes below Single Scan Data Format Change You can also switch between...

Page 99: ...witch to Data Format 1 for a single button press by scanning the Single Scan Data Format 1 bar code below The next bar code that is scanned uses Data Format 1 then reverts back to Data Format 3 Single Scan Primary Data Format Single Scan Data Format 1 Single Scan Data Format 2 Single Scan Data Format 3 ...

Page 100: ...6 12 ...

Page 101: ... Symbologies On Only scan All Symbologies On when needed Note When All Symbologies On is scanned 2D Postal Codes are not enabled 2D Postal Codes must be enabled separately All Symbologies Interleaved 2 of 5 Aztec Code Korea Post China Post Hong Kong 2 of 5 Matrix 2 of 5 Chinese Sensible Han Xin Code MaxiCode Codabar MicroPDF417 Codablock A MSI Codablock F NEC 2 of 5 Code 11 Postal Codes 2D Code 12...

Page 102: ... back cover of this manual The minimum and maximum lengths and the defaults are included with the respective symbologies Codabar Default All Codabar Settings Codabar On Off Codabar Start Stop Characters Start Stop characters identify the leading and trailing ends of the bar code You may either transmit or not transmit Start Stop characters Default Don t Transmit Codabar Check Character Codabar che...

Page 103: ...e two messages are concatenated into one with the D characters omitted Select Require to prevent the scanner from decoding a single D Codabar symbol without its companion This selection has no effect on Codabar symbols without Stop Start D characters Codabar Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 2 for additional information ...

Page 104: ...smits bar code data with or without a check character When Check Character is set to Validate but Don t Transmit the unit only reads Code 39 bar codes printed with a check character but will not transmit the check character with the scanned data When Check Character is set to Validate and Transmit the scanner only reads Code 39 bar codes printed with a check character and will transmit this charac...

Page 105: ...s a Code 39 bar code with the append trigger character s it buffers Code 39 bar codes until it reads a Code 39 bar code that does not have the append trigger The data is then transmitted in the order in which the bar codes were read FIFO Default Off Code 32 Pharmaceutical PARAF Code 32 Pharmaceutical is a form of the Code 39 symbology used by Italian pharmacies This symbology is also known as PARA...

Page 106: ...If this is the case scan the bar code below select the code page with which the bar codes were created see ISO 2022 ISO 646 Character Replacements on page A 7 and scan the value and the Save bar code from the Programming Chart on the inside the back cover of this manual The data characters should then appear properly NUL U DLE P SP SPACE 0 0 V P P W p P SOH A DC1 Q A 1 1 A A Q Q a A q Q STX B DC2 ...

Page 107: ...eck digit with the scanned data When Check Digit is set to Validate and Transmit the scanner only reads Interleaved 2 of 5 bar codes printed with a check digit and will transmit this digit at the end of the scanned data Default No Check Digit Interleaved 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 2 for additional informati...

Page 108: ...ansmit the unit only reads NEC 2 of 5 bar codes printed with a check digit but will not transmit the check digit with the scanned data When Check Digit is set to Validate and Transmit the scanner only reads NEC 2 of 5 bar codes printed with a check digit and will transmit this digit at the end of the scanned data Default No Check Digit Maximum Message Length On Off No Check Digit Validate but Don ...

Page 109: ...Default 4 Maximum Default 80 Code 93 Default All Code 93 Settings Code 93 On Off Code 93 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 0 80 Minimum Default 0 Maximum Default 80 Minimum Message Length Maximum Message Length On Off Minimum Message Length Maximum Message Length ...

Page 110: ...ode 93 bar code that starts with a character other than a space Default Off Code 93 Code Page Code pages define the mapping of character codes to characters If the data received does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code belo...

Page 111: ...of 5 Industrial On Off Straight 2 of 5 Industrial Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 On Off Minimum Message Length Maximum Message Length ...

Page 112: ...f 5 IATA On Off Straight 2 of 5 IATA Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 1 48 Minimum Default 4 Maximum Default 48 On Off Minimum Message Length Maximum Message Length ...

Page 113: ...Matrix 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 On Off Minimum Message Length Maximum Message Length ...

Page 114: ...de 11 bar codes Default Two Check Digits Code 11 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 1 80 Minimum Default 4 Maximum Default 80 On Off One Check Digit Two Check Digits Minimum Message Length Maximum Message Length ...

Page 115: ...rent recommendation to use Code 128 due to its high degree of security and its space efficient design 3 a variation of Code 128 that supports concatenation of neigh boring symbols and 4 the standard layout for bar codes on a blood product label Use the bar codes below to turn concat enation on or off Default Off Code 128 Message Length Scan the bar codes below to change the message length Refer to...

Page 116: ...lt On Code 128 Code Page Code pages define the mapping of character codes to characters If the data received does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the case scan the bar code below select the code page with which the bar codes were created see ISO ...

Page 117: ...8 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 1 80 Minimum Default 1 Maximum Default 80 On Off Minimum Message Length Maximum Message Length ...

Page 118: ...eads symbols with start stop pattern 1 and decodes them as compressed numeric with optional full ASCII start stop pattern 2 Default AIM Telepen Output Telepen Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 1 60 Minimum Default 1 Maximum Default 60 On Off AIM Telepen Output Orig...

Page 119: ...git This selection allows you to specify whether the check digit should be transmitted at the end of the scanned data or not Default On UPC A Number System The numeric system digit of a U P C symbol is normally transmitted at the beginning of the scanned data but the unit can be programmed so it will not transmit it Default On On Off On Off On Off ...

Page 120: ...y read UPC A bar codes that have addenda You must then turn on a 2 or 5 digit addenda listed on page 7 20 Default Not Required UPC A Addenda Separator When this feature is on there is a space between the data from the bar code and the data from the addenda When turned off there is no space Default On 2 Digit Addenda On 2 Digit Addenda Off 5 Digit Addenda On 5 Digit Addenda Off Required Not Require...

Page 121: ...y Otherwise it transmits the first coupon code it reads If you scan the Require Concatenation code the scanner must see and read the coupon code and extended coupon code in a single read to transmit the data No data is output unless both codes are read Default Off Coupon GS1 DataBar Output If you scan coupons that have both UPC and GS1 DataBar codes you may wish to scan and output only the data fr...

Page 122: ...u need to read codes that lead with the 1 number system use UPC E1 page 7 24 Default On UPC E0 Expand UPC E Expand expands the UPC E code to the 12 digit UPC A format Default Off UPC E0 Addenda Required When Required is scanned the scanner will only read UPC E bar codes that have addenda Default Not Required UPC E0 On UPC E0 Off On Off Required Not Required ...

Page 123: ...e check digit should be transmitted at the end of the scanned data or not Default On UPC E0 Leading Zero This feature allows the transmission of a leading zero 0 at the beginning of scanned data To prevent transmission scan Off Default On UPC E0 Addenda This selection adds 2 or 5 digits to the end of all scanned UPC E data Default Off for both 2 Digit and 5 Digit Addenda On Off On Off On Off 2 Dig...

Page 124: ...ion Default Off EAN JAN 13 Default All EAN JAN Settings EAN JAN 13 On Off Convert UPC A to EAN 13 When UPC A Converted to EAN 13 is selected UPC A bar codes are converted to 13 digit EAN 13 codes by adding a zero to the front When Do not Convert UPC A is selected UPC A codes are read as UPC A 5 Digit Addenda On 5 Digit Addenda Off UPC E1 On UPC E1 Off On Off UPC A Converted to EAN 13 ...

Page 125: ... This selection adds 2 or 5 digits to the end of all scanned EAN JAN 13 data Default Off for both 2 Digit and 5 Digit Addenda EAN JAN 13 Addenda Required When Required is scanned the scanner will only read EAN JAN 13 bar codes that have addenda Default Not Required Do not Convert UPC A On Off 2 Digit Addenda On 2 Digit Addenda Off 5 Digit Addenda On 5 Digit Addenda Off Required ...

Page 126: ...addenda When turned Off there is no space Default On Note If you want to enable or disable EAN13 with Extended Coupon Code refer to UPC A EAN 13 with Extended Coupon Code page 7 21 ISBN Translate When On is scanned EAN 13 Bookland symbols are translated into their equivalent ISBN number format Default Off Not Required On Off On Off ...

Page 127: ...specify whether the check digit should be transmitted at the end of the scanned data or not Default On EAN JAN 8 Addenda This selection adds 2 or 5 digits to the end of all scanned EAN JAN 8 data Default Off for both 2 Digit and 5 Digit Addenda On Off On Off 2 Digit Addenda On 2 Digit Addenda Off 5 Digit Addenda On ...

Page 128: ...EAN JAN 8 bar codes that have addenda Default Not Required EAN JAN 8 Addenda Separator When this feature is On there is a space between the data from the bar code and the data from the addenda When turned Off there is no space Default On 5 Digit Addenda Off Required Not Required On Off ...

Page 129: ...rinted with the specified type check character s and will transmit the character s at the end of the scanned data When Check Character is set to Validate Type 10 11 but Don t Transmit the unit will only read MSI bar codes printed with the specified type check character s but will not transmit the check character s with the scanned data On Off Validate Type 10 but Don t Transmit Validate Type 10 an...

Page 130: ...ngth Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 4 48 Minimum Default 4 Maximum Default 48 Validate Type 11 then Type 10 Character and Transmit Disable MSI Check Characters Minimum Message Length Maximum Message Length ...

Page 131: ... DataBar Omnidirectional Default All GS1 DataBar Omnidirectional Settings GS1 DataBar Omnidirectional On Off GS1 DataBar Limited Default All GS1 DataBar Limited Settings GS1 DataBar Limited On Off On Off On Off ...

Page 132: ...ge length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 4 74 Minimum Default 4 Maximum Default 74 Trioptic Code Note If you are going to scan Code 32 Pharmaceutical codes page 7 5 Trioptic Code must be off Trioptic Code is used for labeling magnetic storage media On Off Minimum Message Length Maximum Message Length On Off ...

Page 133: ...ablock A Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 1 600 Minimum Default 1 Maximum Default 600 On Off Minimum Message Length Maximum Message Length ...

Page 134: ...des below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 1 2048 Minimum Default 1 Maximum Default 2048 Label Code The standard Label Code is used in libraries Default Off On Off Minimum Message Length Maximum Message Length On Off ...

Page 135: ...al information Minimum and Maximum lengths 1 2750 Minimum Default 1 Maximum Default 2750 MacroPDF417 MacroPDF417 is an implementation of PDF417 capable of encoding very large amounts of data into multiple PDF417 bar codes When this selection is enabled these multiple bar codes are assembled into a single data string Default On On Off Minimum Message Length Maximum Message Length On Off ...

Page 136: ... 7 2 for additional information Minimum and Maximum lengths 1 366 Minimum Default 1 Maximum Default 366 GS1 Composite Codes Linear codes are combined with a unique 2D composite component to form a new class called GS1 Composite symbology GS1 Composite symbologies allow for the co existence of symbologies already in use Default Off On Off Minimum Message Length Maximum Message Length On Off ...

Page 137: ...nclude UPC A and UPC E EAN 13 and EAN 8 ITF 14 GS1 128 and GS1 128 DataBar and GS1 Composites Any application that accepts GS1 data can be simplified since it only needs to recog nize one data carrier type If GS1 128 Emulation is scanned all retail codes U P C UPC E EAN8 EAN13 are expanded out to 16 digits If the AIM ID is enabled the value will be the GS1 128 AIM ID C1 see Symbology Charts on pag...

Page 138: ...he Code 39 linear component The MicroPDF417 component can only be decoded if TLC39 On is selected The linear component may be decoded as Code 39 even if TLC39 is off Default Off QR Code Default All QR Code Settings QR Code On Off This selection applies to both QR Code and Micro QR Code GS1 DataBar Emulation GS1 Code Expansion Off EAN8 to EAN13 Conversion GS1 Emulation Off On Off On Off ...

Page 139: ...e proper number of codes is reached the data is output in the order specified in the bar codes Default On QR Code Page QR Code pages define the mapping of character codes to characters If the data received does not display with the proper characters it may be because the bar code being scanned was created using a code page that is different from the one the host program is expecting If this is the...

Page 140: ... bar code with the append trigger character s it buf fers the number of Data Matrix bar codes determined by information encoded in those bar codes Once the proper number of codes is reached the data is output in the order specified in the bar codes Default On Data Matrix Code Page Data Matrix Code pages define the mapping of character codes to characters If the data received does not display with ...

Page 141: ... data characters should then appear properly MaxiCode Default All MaxiCode Settings MaxiCode On Off MaxiCode Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 1 150 Minimum Default 1 Maximum Default 150 Data Matrix Code Page On Off Minimum Message Length Maximum Message Length ...

Page 142: ...ar code with the append trigger character s it buffers the number of Aztec bar codes determined by information encoded in those bar codes Once the proper number of codes is reached the data is output in the order specified in the bar codes Default On Aztec Code Page Aztec Code pages define the mapping of character codes to characters If the data received does not display with the proper characters...

Page 143: ...ters should then appear properly Chinese Sensible Han Xin Code Default All Han Xin Settings Han Xin Code On Off Han Xin Code Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 2 for additional information Minimum and Maximum lengths 1 7833 Minimum Default 1 Maximum Default 7833 Aztec Code Page On Off Minimum Message Length Maximum Messag...

Page 144: ...an be active at a time If you scan a second 2D postal code selection the first selection is overwritten Default 2D Postal Codes Off Single 2D Postal Codes 2D Postal Codes Off Australian Post On British Post On Canadian Post On Intelligent Mail Bar Code On Japanese Post On KIX Post On Planet Code On Also see Planet Code Check Digit page 7 47 Postal 4i On ...

Page 145: ... and B Fields On InfoMail On InfoMail and British Post On Intelligent Mail Bar Code and Postnet with B and B Fields On Postnet and Postal 4i On Postnet and Intelligent Mail Bar Code On Postal 4i and Intelligent Mail Bar Code On Postal 4i and Postnet with B and B Fields On Planet Code and Postnet On ...

Page 146: ...On Planet Code Postnet and Intelligent Mail Bar Code On Planet Code Postal 4i and Intelligent Mail Bar Code On Postnet Postal 4i and Intelligent Mail Bar Code On Planet Code Postal 4i and Postnet with B and B Fields On Planet Code Intelligent Mail Bar Code and Postnet with B and B Fields On Postal 4i Intelligent Mail Bar Code and Postnet with B and B Fields On ...

Page 147: ...ation is applied to customer fields in Australian 4 State symbols Bar Output lists the bar patterns in 0123 format Numeric N Table causes that field to be interpreted as numeric data using the N Table Alphanumeric C Table causes the field to be interpreted as alphanumeric data using the C Table Refer to the Australian Post Specification Tables Planet Code Postal 4i Intelligent Mail Bar Code and Po...

Page 148: ...ong Kong 2 of 5 Default All China Post Hong Kong 2 of 5 Settings China Post Hong Kong 2 of 5 On Off China Post Hong Kong 2 of 5 Message Length Scan the bar codes below to change the message length Refer to Message Length Description page 7 2 for addi tional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 80 Bar Output Numeric N Table Alphanumeric C Table Combination ...

Page 149: ...tion page 7 2 for addi tional information Minimum and Maximum lengths 2 80 Minimum Default 4 Maximum Default 48 Korea Post Check Digit This selection allows you to specify whether the check digit should be transmitted or not Default Don t Transmit Maximum Message Length On Off Minimum Message Length Maximum Message Length Transmit Check Digit Don t Transmit Check Digit ...

Page 150: ...7 50 ...

Page 151: ... following chart indicates the equiva lents of these five characters for different countries Function Code HEX ASCII Value Full ASCII CTRL X Mode NUL 00 SOH 01 A STX 02 B ETX 03 C EOT 04 D ENQ 05 E ACK 06 F BEL 07 G BS 08 H HT 09 I LF 0A J VT 0B K FF 0C L CR 0D M SO 0E N SI 0F O DLE 10 P DC1 11 Q DC2 12 R DC3 13 S DC4 14 T NAK 15 U SYN 16 V ETB 17 W CAN 18 X EM 19 Y SUB 1A Z ESC 1B FS 1C GS 1D RS ...

Page 152: ...L make ACK 06 CTRL break CNTRL break BEL 07 CR Enter RETURN BS 08 Reserved APPLE make HT 09 Tab TAB LF 0A Reserved APPLE break VT 0B Tab TAB FF 0C Delete Del CR 0D CR Enter RETURN SO 0E Insert Ins Help SI 0F Escape ESC DLE 10 F11 F11 DC1 11 Home Home DC2 12 Print Prnt Scrn DC3 13 Back Space BACKSPACE DC4 14 Back Tab LSHIFT TAB NAK 15 F12 F12 SYN 16 F1 F1 ETB 17 F2 F2 CAN 18 F3 F3 EM 19 F4 F4 SUB 1...

Page 153: ...y setting that will be removed when the unit is power cycled Show Decoder Revision Scan the bar code below to output the decoder revision Show Scan Driver Revision Scan the bar code below to output the scan driver revision Show Software Revision Scan the bar code below to output the current software revision unit serial number and other product information Show Data Format Scan the bar code below ...

Page 154: ...canner Decoding apps and Data Formatting apps can be created using TotalFreedom For further information about TotalFreedom go to our website at www honeywellaidc com Application Plug Ins Apps Any apps that you are using can be turned off or on by scanning the following bar codes Apps are stored in groups Decoding and Formatting You can enable and disable these groups of apps by scanning that group...

Page 155: ... configu ration data is grouped into different categories Each category is displayed as a tree item under the Configure tree node in the application explorer When one of these tree nodes is clicked the right hand side is loaded with the parameters form belonging to that particular category The Configure tree option has all the programming and con figuration parameters specified for a scanner You c...

Page 156: ...ivate Defaults bar code also causes both the scanner and the host to perform a reset and become unlinked You must relink pair the scanner to the host See Wireless System Operation beginning on page 3 1 for additional information The Menu Commands beginning on page 10 4 list the factory default settings for each of the commands indicated by an aster isk on the programming pages This selection erase...

Page 157: ...nown a wildcard can be used Tag A 3 character case insensitive field that identifies the desired menu command group For example all RS232 configuration settings are identified with a Tag of 232 SubTag A 3 character case insensitive field that identifies the desired menu command within the tag group For example the SubTag for the RS232 baud rate is BAD Data The new value for a menu setting identifi...

Page 158: ...ndicates the command was good but the Data field entry was out of the allowable range for this Tag and SubTag combination e g an entry for a minimum message length of 100 when the field will only accept 2 characters When responding the device echoes back the command sequence with the status character inserted directly before each of the punctuation marks the period exclamation point comma or semic...

Page 159: ...d until the deactivate command is sent or until the serial time out has been reached see Read Time Out on page 4 8 for a description and the serial command on page 10 11 Resetting the Custom Defaults If you want the custom default settings restored to your scanner scan the Activate Custom Defaults bar code below This resets the scanner to the custom default settings If there are no custom defaults...

Page 160: ...llic KBDCTY81 2 1 Azeri Latin KBDCTY80 2 1 Belarus KBDCTY82 2 1 Belgium KBDCTY1 2 1 Bosnia KBDCTY33 2 1 Brazil KBDCTY16 2 1 Brazil MS KBDCTY59 2 2 Bulgaria Cyrillic KBDCTY52 2 2 Bulgaria Latin KBDCTY53 2 2 Canada French legacy KBDCTY54 2 2 Canada French KBDCTY18 2 2 Canada Multilingual KBDCTY55 2 2 Croatia KBDCTY32 2 2 Czech KBDCTY15 2 2 Czech Programmers KBDCTY40 2 2 Czech QWERTY KBDCTY39 2 2 Cze...

Page 161: ...BDCTY74 2 5 Mongolian Cyrillic KBDCTY86 2 6 Norway KBDCTY9 2 6 Poland KBDCTY20 2 6 Polish 214 KBDCTY57 2 6 Polish Programmers KBDCTY58 2 6 Portugal KBDCTY13 2 6 Romania KBDCTY25 2 6 Russia KBDCTY26 2 6 Russian MS KBDCTY67 2 6 Russian Typewriter KBDCTY68 2 6 SCS KBDCTY21 2 6 Serbia Cyrillic KBDCTY37 2 7 Serbia Latin KBDCTY36 2 7 Slovakia KBDCTY22 2 7 Slovakia QWERTY KBDCTY49 2 7 Slovakia QWERTZ KBD...

Page 162: ...r Case KBDCNV2 2 10 Control Character Output Control Character Output Off KBDNPE0 2 10 Control Character Output On KBDNPE1 2 10 Keyboard Modifiers Control X Off KBDCAS0 2 11 DOS Mode Control X KBDCAS1 2 11 Windows Mode Control X KBDCAS2 2 10 Windows Mode Prefix Suffix Off KBDCAS3 2 11 Turbo Mode Off KBDTMD0 2 11 Turbo Mode On KBDTMD1 2 11 Numeric Keypad Off KBDNPS0 2 11 Numeric Keypad On KBDNPS1 2...

Page 163: ...5 Remote MasterMind for USB ReM Off REMIFC0 2 15 ReM On REMIFC1 2 15 Plug and Play Codes Gilbarco Terminal PAPGLB 2 16 Honeywell Bioptic Aux Port PAPBIO 2 16 Datalogic Magellan Aux Port PAPMAG 2 16 NCR Bioptic Aux Port PAPNCR 2 17 Wincor Nixdorf Terminal PAPWNX 2 17 Wincor Nixdorf Beetle PAPBTL 2 17 Wincor Nixdorf RS232 Mode A PAPWMA 2 18 Baud Rate 300 BPS 232BAD0 2 18 600 BPS 232BAD1 2 18 1200 BP...

Page 164: ...VG1602 Corded Interface Setting the VG1602 Corded Interface USB Communication Corded Scanner BTUENA1 2 23 Bluetooth Communication Cordless Scanner BTUENA0 2 23 Corded USB PC or Macintosh Keyboard Corded USB Keyboard PC BTUMID124 2 23 Corded USB Keyboard Mac BTUMID125 2 23 Corded USB HID POS Corded USB HID POS Interface BTUMID131 2 23 Corded USB Serial Corded USB Serial BTUMID130 2 24 Corded CTS RT...

Page 165: ... 3 9 Flexible Power Management Full Power BT_TXP100 3 10 Medium Power BT_TXP35 3 10 Medium Low Power BT_TXP5 3 10 Low Power BT_TXP1 3 10 Multiple Scanner Operation Multiple Scanner Operation BASCON2 DNG3 3 10 Scanner Name Name 1 7 BT_NAM 3 11 Reset RESET_ 3 11 Scanner Name BT_NAM 3 11 Application Work Group Selections Group 0 GRPSEL0 3 12 Group 1 6 GRPSEL 3 12 Resetting the Factory Defaults All Ap...

Page 166: ...RC 3 19 Delete Last Code Delete Last Code BATUND 3 20 Clear All Codes Clear All Codes BATCLR 3 20 Transmit Records to Host Transmit Inventory Records BAT_TX 3 20 Batch Mode Transmit Delay Off BATDLY0 3 20 Short ms BATDLY250 3 20 Medium ms BATDLY500 3 20 Long ms BATDLY1000 3 20 Host Command Acknowledgment Host ACK On HSTACK1 3 22 Host ACK Off HSTACK0 3 22 Host ACK Timeout HSTATO 3 22 Input Output S...

Page 167: ... 9000Hz BEPFQ14200 4 5 Beeper Pitch Error Frequency Razz 250 min 200Hz BEPFQ2800 4 6 Medium 3250 BEPFQ23250 4 6 High 4200 max 9000Hz BEPFQ24200 4 6 Beeper Duration Good Read Normal Beep BEPBIP0 4 6 Short Beep BEPBIP1 4 6 LED Good Read Off BEPLED0 4 6 On BEPLED1 4 6 Number of Beeps Error 1 BEPERR3 4 7 Range 1 9 BEPERR 4 7 Number of Beeps Good Read 1 BEPRPT1 4 7 Range 1 9 BEPRPT 4 7 Good Read Delay ...

Page 168: ...STDEN1 4 11 Deactivation Character Range 0 255 14 DC4 HSTDCH 4 11 Illumination Lights Lights On SCNLED1 4 11 Lights Off SCNLED0 4 11 Aimer Delay 200 milliseconds SCNDLY200 4 12 400 milliseconds SCNDLY400 4 12 Off no delay SCNDLY0 4 12 User Specified Aimer Delay Range 0 4 000 ms SCNDLY 4 12 Aimer Mode Off SCNAIM0 4 12 Interlaced SCNAIM2 4 12 Centering Window Centering On DECWIN1 4 13 Centering Off ...

Page 169: ...efix Suffix Selections Add CR Suffix to All Symbologies VSUFCR 5 2 Prefix Add Prefix PREBK2 5 2 Clear One Prefix PRECL2 5 2 Clear All Prefixes PRECA2 5 2 Suffix Add Suffix SUFBK2 5 2 Clear One Suffix SUFCL2 5 2 Clear All Suffixes SUFCA2 5 2 Function Code Transmit Enable RMVFNC0 5 3 Disable RMVFNC1 5 3 Intercharacter Delay Range 0 1000 5ms increments DLYCHR 5 3 User Specified Intercharacter Delay D...

Page 170: ... Data Format VSAF_0 6 11 Single Scan Data Format 1 VSAF_1 6 11 Single Scan Data Format 2 VSAF_2 6 11 Single Scan Data Format 3 VSAF_3 6 11 Symbologies All Symbologies All Symbologies Off ALLENA0 7 1 All Symbologies On ALLENA1 7 1 Codabar Default All Codabar Settings CBRDFT 7 2 Off CBRENA0 7 2 On CBRENA1 7 2 Codabar Start Stop Char Don t Transmit CBRSSX0 7 2 Transmit CBRSSX1 7 2 Codabar Check Char ...

Page 171: ...of 5 Check Digit No Check Char I25CK20 7 7 Validate But Don t Transmit I25CK21 7 7 Validate and Transmit I25CK22 7 7 Interleaved 2 of 5 Message Length Minimum 2 80 4 I25MIN 7 7 Maximum 2 80 80 I25MAX 7 7 NEC 2 of 5 Default All NEC 2 of 5 Settings N25DFT 7 8 Off N25ENA0 7 8 On N25ENA1 7 8 NEC 2 of 5 Check Digit No Check Char N25CK20 7 8 Validate But Don t Transmit N25CK21 7 8 Validate and Transmit ...

Page 172: ... 7 13 Maximum 1 80 80 X25MAX 7 13 Code 11 Default All Code 11 Settings C11DFT 7 14 Off C11ENA0 7 14 On C11ENA1 7 14 Code 11 Check Digits Required 1 Check Digit C11CK20 7 14 2 Check Digits C11CK21 7 14 Code 11 Message Length Minimum 1 80 4 C11MIN 7 14 Maximum 1 80 80 C11MAX 7 14 Code 128 Default All Code 128 Settings 128DFT 7 15 Off 128ENA0 7 15 On 128ENA1 7 15 ISBT Concatenation Off ISBENA0 7 15 O...

Page 173: ...quired Not Required UPAARQ0 7 20 Required UPAARQ1 7 20 UPC A Addenda Separator Off UPAADS0 7 20 On UPAADS1 7 20 UPC A EAN 13 with Extended Coupon Code Off CPNENA0 7 21 Allow Concatenation CPNENA1 7 21 Require Concatenation CPNENA2 7 21 Coupon GS1 DataBar Output GS1 Output Off CPNGS10 7 21 GS1 Output On CPNGS11 7 21 UPC E0 Default All UPC E Settings UPEDFT 7 22 Off UPEEN00 7 22 On UPEEN01 7 22 UPC ...

Page 174: ...3AD50 7 25 EAN JAN 13 Addenda Required Not Required E13ARQ0 7 25 Required E13ARQ1 7 25 EAN JAN 13 Addenda Separator Off E13ADS0 7 26 On E13ADS1 7 26 ISBN Translate Off E13ISB0 7 26 On E13ISB1 7 26 EAN JAN 8 Default All EAN JAN 8 Settings EA8DFT 7 27 Off EA8ENA0 7 27 On EA8ENA1 7 27 EAN JAN 8 Check Digit Off EA8CKX0 7 27 On EA8CKX1 7 27 EAN JAN 8 Addenda 2 Digit Addenda Off EA8AD20 7 27 2 Digit Add...

Page 175: ...Limited Default All GS1 DataBar Limited Settings RSLDFT 7 31 Off RSLENA0 7 31 On RSLENA1 7 31 GS1 DataBar Expanded Default All GS1 DataBar Expanded Settings RSEDFT 7 32 Off RSEENA0 7 32 On RSEENA1 7 32 GS1 DataBar Expanded Msg Length Minimum 4 74 4 RSEMIN 7 32 Maximum 4 74 74 RSEMAX 7 32 Trioptic Code Off TRIENA0 7 32 On TRIENA1 7 32 Codablock A Default All Codablock A Settings CBADFT 7 33 Off CBA...

Page 176: ...1 7 37 GS1 DataBar Emulation EANEMU2 7 36 GS1 Code Expansion Off EANEMU3 7 38 EAN8 to EAN13 Conversion EANEMU4 7 38 GS1 Emulation Off EANEMU0 7 38 TCIF Linked Code 39 On T39ENA1 7 38 Off T39ENA0 7 38 QR Code Default All QR Code Settings QRCDFT 7 38 On QRCENA1 7 38 Off QRCENA0 7 38 QR Code Msg Length Minimum 1 7089 1 QRCMIN 7 39 Maximum 1 7089 7089 QRCMAX 7 39 QR Code Append On QRCAPP1 7 39 Off QRC...

Page 177: ...ult All Han Xin Code Settings HX_DFT 7 43 On HX_ENA1 7 43 Off HX_ENA0 7 43 Chinese Sensible Han Xin Code Msg Length Minimum 1 7833 1 HX_MIN 7 43 Maximum 1 7833 7833 HX_MAX 7 43 Postal Codes 2D 2D Postal Codes Off POSTAL0 7 44 Single 2D Postal Codes Australian Post On POSTAL1 7 44 British Post On POSTAL7 7 44 Canadian Post On POSTAL30 7 44 Intelligent Mail Bar Code On POSTAL10 7 44 Japanese Post On...

Page 178: ... On POSTAL23 7 46 Combination 2D Postal Codes continued Postnet Postal 4i and Intelligent Mail Bar Code On POSTAL24 7 46 Planet Postal 4i and Postnet with B and B Fields On POSTAL25 7 46 Planet Intelligent Mail Bar Code and Postnet with B and B Fields On POSTAL26 7 46 Postal 4i Intelligent Mail Bar Code and Postnet with B and B Fields On POSTAL27 7 46 Planet Postal 4i Intelligent Mail Bar Code and...

Page 179: ... KPCCHK1 7 49 Don t Transmit Check Digit KPCCHK0 7 49 Utilities Add Code I D Prefix to All Symbologies Temporary PRECA2 BK2995C80 9 1 Show Decoder Revision REV_DR 9 1 Show Scan Driver Revision REV_SD 9 1 Show Software Revision REVINF 9 1 Show Data Format DFMBK3 9 1 Test Menu On TSTMNU1 9 2 Off TSTMNU0 9 2 Application Plug Ins Apps Decoding Apps On PLGDCE1 9 2 Decoding Apps Off PLGDCE0 9 2 Formatti...

Page 180: ...10 24 ...

Page 181: ... C Storage Temperature 4 to 140 F 20 to 60 C Charging Temperature 41 to 104 F 5 to 40 C Humidity Up to 95 non condensing Drop Operational after 30 drops from 4 feet 1 2m to concrete Environmental Sealing IP42 Vibration Withstands 10G peak from 10 to 500 Hz ESD 12kV air 8kV direct Image Image Size 640 x 480 pixels Scan Performance Pitch Skew 60 70 Symbol Contrast 35 Motion Tolerance up to 10cm per ...

Page 182: ...Safety Labels 20 mil Code 39 66 425mm 2 6 16 73 in 6 7 mil PDF417 62 108mm 2 44 4 25 in 10mil Data Matrix 54 108mm 2 13 4 25 in 20mil QR Code 41 230mm 1 61 9 05 in Parameter Specification Compliance label locations Illumination output Part number serial number and revision information location ...

Page 183: ...te Use of a cable with improper pin assignments may lead to damage to the unit Use of any cables not provided by the manufacturer may result in damage not covered by your warranty Micro B USB 1 2 3 4 5 1 Vcc 2 Data 3 Data 4 ID 5 Ground ...

Page 184: ...11 4 ...

Page 185: ...y or if the scanner isn t operating well clean the window with gentle dish soap and water Inspecting Cords and Connectors Inspect the interface cable and connector for wear or other signs of damage A badly worn cable or damaged connector may interfere with scanner operation Contact your distributor for information about cable replacement Cable replacement instructions are on page 12 2 Do not subme...

Page 186: ...e back cover of the scanner Step 2 Lift the back cover up and out to expose the battery Step 3 Lift out the battery and replace making sure the contacts on the battery line up with the contacts in the scanner Step 4 Replace the back cover and secure with the Phillips head screw ...

Page 187: ...ered into the application The bar code is displayed on the host device correctly but you still have to press a key to enter it the Enter Return key or the Tab key for example You need to program a suffix Programming a suffix enables the scanner to output the bar code data plus the key you need such as CR to enter the data into your application Refer to Prefix Suffix Overview on page 5 1 for furthe...

Page 188: ...12 4 ...

Page 189: ...bar Fm 0 1 a 61 Code 11 H3 h 68 Code 128 Cm 0 1 2 4 j 6A Code 32 Pharmaceutical PARAF X0 3C Code 39 supports Full ASCII mode Am 0 1 3 4 5 7 b 62 TCIF Linked Code 39 TLC39 L2 T 54 Code 93 and 93i Gm 0 9 A Z a m i 69 EAN Em 0 1 3 4 d 64 EAN 13 including Bookland EAN E0 d 64 EAN 13 with Add On E3 d 64 EAN 13 with Extended Coupon Code E3 d 64 EAN 8 E4 D 44 EAN 8 with Add On E3 D 44 GS1 GS1 DataBar em ...

Page 190: ...ologies 99 Aztec Code zm 0 9 A C z 7A Chinese Sensible Code Han Xin Code X0 H 48 Codablock A O6 0 1 4 5 6 V 56 Codablock F Om 0 1 4 5 6 q 71 Code 49 Tm 0 1 2 4 l 6C Data Matrix dm 0 6 w 77 GS1 em 0 3 y 79 GS1 Composite em 0 3 y 79 GS1 DataBar Omnidirectional em 0 3 y 79 MaxiCode Um 0 3 x 78 PDF417 Lm 0 2 r 72 MicroPDF417 Lm 0 5 R 52 QR Code Qm 0 6 s 73 Micro QR Code Qm s 73 AIM Honeywell Symbology...

Page 191: ... Keyboard Control ASCII CTRL X Mode Control X Mode Off KBDCAS0 Windows Mode Control X Mode On KBDCAS2 DEC HEX Char CTRL X CTRL X function 0 00 NUL Reserved CTRL 1 01 SOH NP Enter CTRL A Select all 2 02 STX Caps Lock CTRL B Bold 3 03 ETX ALT Make CTRL C Copy 4 04 EOT ALT Break CTRL D Bookmark 5 05 ENQ CTRL Make CTRL E Center 6 06 ACK CTRL Break CTRL F Find 7 07 BEL Enter Ret CTRL G 8 08 BS Apple Ma...

Page 192: ...1 47 G 103 67 g 40 28 72 48 H 104 68 h 41 29 73 49 I 105 69 i 42 2A 74 4A J 106 6A j 43 2B 75 4B K 107 6B k 44 2C 76 4C L 108 6C l 45 2D 77 4D M 109 6D m 46 2E 78 4E N 110 6E n 47 2F 79 4F O 111 6F o 48 30 0 80 50 P 112 70 p 49 31 1 81 51 Q 113 71 q 50 32 2 82 52 R 114 72 r 51 33 3 83 53 S 115 73 s 52 34 4 84 54 T 116 74 t 53 35 5 85 55 U 117 75 u 54 36 6 86 56 V 118 76 v 55 37 7 87 57 W 119 77 w ...

Page 193: ...C 146 92 Æ F3 0x3D 147 93 ô F4 0x3E 148 94 ö F5 0x3F 149 95 ò F6 0x40 150 96 û F7 0x41 151 97 ù F8 0x42 152 98 ÿ F9 0x43 153 99 Ö F10 0x44 154 9A š Ü F11 0x57 155 9B F12 0x58 156 9C œ Numeric Keypad 0x4E 157 9D Numeric Keypad 0x4A 158 9E ž Numeric Keypad 0x37 159 9F Ÿ ƒ Caps Lock 0x3A 160 A0 á Num Lock 0x45 161 A1 í Left Alt 0x38 162 A2 ó Left Ctrl 0x1D 163 A3 ú Left Shift 0x2A 164 A4 ñ Right Shif...

Page 194: ...2 Â 195 C3 Ã 196 C4 Ä 197 C5 Å í 198 C6 Æ 199 C7 Ç 200 C8 È 201 C9 É 202 CA Ê 203 CB Ë 204 CC Ì 205 CD Í 206 CE Î 207 CF Ï 208 D0 Ð 209 D1 Ñ 210 D2 Ò 211 D3 Ó 212 D4 Ô 213 D5 Õ 214 D6 Ö 215 D7 216 D8 Ø 217 D9 Ù 218 DA Ú 219 DB Û 220 DC Ü 221 DD Ý 222 DE Þ 223 DF ß 224 E0 à α 225 E1 á ß 226 E2 â Γ Extended ASCII Characters Continued DEC HEX CP 1252 ASCII Alternate Extended PS2 Scan Code ...

Page 195: ...37 ED í φ 238 EE î ε 239 EF ï 240 F0 ð 241 F1 ñ 242 F2 ò 243 F3 ó 244 F4 ô 245 F5 õ 246 F6 ö 247 F7 248 F8 ø 249 F9 ù 250 FA ú 251 FB û 252 FC ü ⁿ 253 FD ý 254 FE þ 255 FF ÿ Code Page Selection Method Country Standard Keyboard Country Honeywell Code Page Option United States standard ASCII ISO IEC 646 IRV n a 1 Automatic National Character Replacement ISO IEC 2022 n a 2 default Binary Code page n ...

Page 196: ...46 CH 6 86 Sweden Finland extended Annex C ISO IEC 646 11 2 82 Ireland ISO IEC 646 207 73 97 Denmark ISO IEC 646 08 8 88 Norway ISO IEC 646 60 9 94 Italy ISO IEC 646 15 5 85 Portugal ISO IEC 646 16 13 92 Spain ISO IEC 646 17 10 90 Spain ISO IEC 646 85 51 91 Code Page Selection Method Country Standard Keyboard Country Honeywell Code Page Option ...

Page 197: ...28 98 CN 92 99 GB 7 87 FR 3 83 à ç µ é ù è DE 4 84 Ä Ö Ü ä ö ü ß CH 6 86 ù à é ç ê î ô ä ö ü û SE FI 2 82 É Ä Ö Å Ü é ä ö å ü DK 8 88 Æ Ø Å æ ø å NO 9 94 Æ Ø Å æ ø å IE 73 97 Ó É Í Ú Á ó é í ú á IT 5 85 ç é ù à ò è ì PT 13 92 Ã Ç Õ ã ç õ ES 10 90 Ñ ñ ç ES 51 91 Ñ Ç ñ ç COUNTRY Country Keyboard Honeywell CodePage ISO IEC 646 National Character Replacements ...

Page 198: ... 54 59 3A 3B 3C 3E 3F 38 40 3D 5A 5F 64 5B 60 65 5C 61 66 5D 62 67 63 68 69 6A 6C 104 Key U S Style Keyboard 6E 70 71 72 73 74 75 76 77 78 79 7A 7B 7C 7D 7E 4B 50 55 4C 51 56 01 02 03 04 05 06 07 08 09 0A 0B 0C 0D 0F 10 11 12 13 14 15 16 17 18 19 1A 1B 1C 1E 2C 1F 20 21 22 23 24 25 26 27 28 29 2B 39 2E 2F 30 31 32 33 34 35 36 37 53 4F 54 59 3A 3B 3C 3E 3F 38 40 3D 5A 5F 64 5B 60 65 5C 61 66 5D 62 ...

Page 199: ...Sample Symbols UPC A 0 123456 7890 Interleaved 2 of 5 1234567890 EAN 13 9 780330 290951 Code 128 Code 128 Code 39 BC321 Codabar A13579B Code 93 123456 9 Straight 2 of 5 Industrial 123456 ...

Page 200: ...6543210 Matrix 2 of 5 GS1 DataBar 01 00123456789012 PDF417 Car Registration Data Matrix Test Symbol QR Code Numbers Aztec Package Label MaxiCode Test Message Micro PDF417 Test Message Postnet Zip Code ...

Page 201: ...4 CB 4 State Customer Bar Code 01 234 567094 987654321 01234567891 ID tag UPU 4 State J18CUSA8E6N062315014880T ...

Page 202: ...Programming Chart 0 1 2 3 4 5 6 7 8 9 ...

Page 203: ...Programming Chart Note If you make an error while scanning the letters or digits before scanning Save scan Discard scan the correct letters or digits and Save again A B C D E F Save Discard Reset ...

Page 204: ...Honeywell Scanning Mobility 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com VG1602 UG Rev B 11 15 ...

Reviews: