NCR Prefix/Suffix
When set to
Transmit
, both the NCR prefix and suffix are transmitted with
bar codes. Usually, prefixes and suffixes are programmed using the Data
Editing selections (see
beginning on page 4-1), however, the
following commands override any other prefix/suffix settings.
Default =
Don’t Transmit.
NCR NOF (Not-on-File) Error
A scanner receives an NOF (Not on File) command from the POS when-
ever it cannot cross-reference the bar code to a price parameter. When set
to
On
, the error tone sounds (set via
for an NOF, and disables the scanner while the cashier looks up the price
manually. When set to
Off
, no sound is emitted for an NOF.
Default = Off.
Scanner to Bioptic Communication
The following settings are used to set up communication between Honeywell
scanners and bioptic scanners.
Note: The scanner’s baud rate must be set to 38400 and the RS232 Timeout
must be set to 3000 in order to communicate with a bioptic scanner. See
on page 2-25, and
further information.
Transmit
* Don’t Transmit
On
* Off