About This Manual

 

This manual introduces the interface and menu operations of the Honeywell VISTA series products. For 
the product installation, see related installation guide.

Summary of Contents for VISTA CA-FP-100F

Page 1: ...ersion 1 0 Date Dec 2011 CA FP 100F CA FP 100FS CA FP 100FID CA FP 100FIC About This Manual This manual introduces the interface and menu operations of the Honeywell VISTA series products For the product installation see related installation guide ...

Page 2: ......

Page 3: ... Date Format 15 4 1 3 Advanced Settings 15 4 2 Power Managementê 16 4 2 1 Power Settings 16 4 3 Communication related Settings 17 4 4 Log Settings 18 4 5 Access Optionsê 18 4 5 1 Access Control Function Description 19 4 5 2 Access Control Verification Flow 20 4 5 3Function Introduction 20 4 5 4 Duress Alarm 26 4 5 5 Verification Failure Alarm 27 4 5 6 Group Verification Typeê 27 4 4 Automatic Test...

Page 4: ......

Page 5: ...tion may easily lead to response slowdown and verification pass rate decrease It is recommended to use sunshades and heat sink devices for protection of the FRTs outdoors We recommend you to use the FRT properly so as to achieve the optimal recognition effect and verification speed 1 Install a CA FP 100Fxx FRT and then enroll your fingerprint for comparison Installation Enrollment Recognition Reco...

Page 6: ...ct our technical personnel 5 About This Manual l Our products are subject to update from time to time so our company will neither make a commitment to guarantee the consistency between the actual products and this document nor assume any responsibility for any dispute arising out of the discrepancy between the actual technical parameters and this manual This document is subject to change without p...

Page 7: ...erprint verification which takes about 2 seconds Upon verification the system displays a prompt about whether the verification succeeds or not and then stores the successful matching record in the CA FP 100Fxx FRT 2 3 Match Threshold The match threshold is set to achieve a trade off between the possibilities of false rejection and false acceptance The false acceptance means the fingerprint recogni...

Page 8: ...istrators refer to the users who are granted the right to perform all operations except performing advanced settings and enrolling administrators and super administrators l Super administrators refer to users who have access to all system functions and modify all system settings Note When the super administrators are not enrolled the registrars can enroll the administrators and super administrator...

Page 9: ...de applies to a small portion of the general public who can enroll their fingerprints successfully but have difficulty in fingerprint verification due to their poor fingerprint quality l Password enrollment This enrollment mode applies to about one percent the actual number may vary slightly of the general public who are unable to enroll their fingerprints successfully If an administrator has alre...

Page 10: ... interface press or key to select the digit you want to enter such as the hundreds place press OK button press or key to select the number you want to enter press OK button then move to the ten place as the operation above press OK button for 3 seconds to confirm the enrollment 3 1 2Enroll a Password 1 Select Menu Mange User Enroll User to display the Enroll User interface Select Enroll Pwd and pr...

Page 11: ...oceed New Enroll UserID 00008 ESC Exit OK Y 3 Input a number from 1 65534 in the User ID field Press OK to display the fingerprint enrollment interface New Enroll 00008 0 Place Finger ESC Exit 4 Place the same finger for three consecutive times on the fingerprint reader according to system prompts If the enrollment succeeds the following information is displayed New Enroll 00003 0 Input Pwd ESC Ex...

Page 12: ... Select Menu Mange User Enroll User to display the Enroll User interface Select Reg RFID and press OK to proceed Reg RFID New Enroll ESC Exit OK Save 2 Press OK to confirm and proceed New Enroll Show the card User ID 00010 ESC Exit OK Save 3 Input a number from 1 65534 in the User ID field Press OK to display the ID card enrollment interface New Enroll 000010 C ESC Exit OK Save 4 Swipe your card a...

Page 13: ...roves that your fingerprints are not suitable for recognition and you need to adopt the fingerprint and password verification mode 3 3 Verification Modes 3 3 1 Fingerprint Verification You can adopt 1 1 and 1 N matching modes for fingerprint identification 1 1 1 fingerprint matching ID fingerprint In the 1 1 fingerprint matching mode the FRT compares the current fingerprint collected through the f...

Page 14: ...ngerprints stored in the FRT Operation steps Place your finger on the initial interface to display the following interface FP Verify Remove Finger If the verification succeeds the interface will be displayed Verify UserID 00001 Verified If the verification fails the system will display the following interface FP Verify Please Try Agn After the above interface is displayed 0 5 seconds the system wi...

Page 15: ...ailure or Poor Fingerprint Quality Finger is too dry or dirty Rub your fingers against your palm because rubbing yields oil Moisturize your finger by breathing on it Apply insufficient pressure Apply pressure lightly and evenly during the capturing process Select fingers for enrollment Left and right index fingers or middle fingers are recommended Select the fingers without worn out or damaged fin...

Page 16: ...tem security The operations on administrator settings are as follows 1 The brand new FRT does not assign any administrator so you can press Menu to access the system directly and the following interface is displayed Menu Mange User Options USB Mgnt 2 Press OK to display the Mange User interface Mange User Enroll User Enroll Admin Delete 3 Select Enroll Admin through the key Mange User Enroll User ...

Page 17: ...ding to system prompt Note About deleting the administrator Privilege and Clear all Data There are such items in the Advanced Settings on some models of devices for detail please refer to 4 1 7Advanced Settings Such deletions can also be executed by Access Control Management Software Steps as below Open the Access Control Management Software Click Basic settings Device management others read optio...

Page 18: ...l devices provide this setting and Auto Test These submenus will be described in the following part 4 1 System option Enter system option menu and the following information will appear 4 1 1 Time Settings Set the current date and time displayed on the FRT screen Select Time Opt and press OK to display the following interface YYYY MM DD 24H 2012 7 13 9 34 29 ESC Exit OK To modify date and time plac...

Page 19: ... management rights deleting attendance records deleting all data and setting match thresholds as shown below Adv Option Default Del AttLogs Del All Data Del Adm Perm Show Score N Match Lvl 45 1 1 Lvl 35 Ext FP Dev N Firmware Upd Buzzer N AntiPassback None Alg Ver 10 Note The menu options above contain some optional functions If the actual product does not have one or several of the options above t...

Page 20: ...This option is used to set the version number of the fingerprint algorithm Select 9 to adopt algorithm version 9 0 and 10 to adopt algorithm version 10 0 Please select the algorithm version with caution because the fingerprint templates of these two algorithm versions are incompatible Note some of the device will be prompted to remove the user information and attendance data when change the algori...

Page 21: ...to IP Addr 192 168 1 201 NetMask 255 255 255 0 Gateway 192 168 1 1 Ethernet Y RS232 N RS485 N COMM Key 0 1 BaudRate This option is used to set the baud rate for the communication between the FRT and the PC It includes five options 9600 19200 38400 57600 and 115200 The high baud rate is recommended for the RS232 communication to achieve high communication speed while the low baud rate is recommende...

Page 22: ...xists and the user checks in again within the specified period unit minute his her second attendance record will not be stored 4 5 Access Optionsê The access control settings are valid for the FRTs with professional access control functions The menu item Access Options is inexistent in the fingerprint time attendance machines and the devices with simple access control functions Select Access Optio...

Page 23: ...on The access control setting items include the user s access time segments and access combinations The setting items for each user include The group that the user belongs to and the available access time segments for group and user User grouping means the allocation of a user to a certain group for example Group 1 or Group 2 A group or user can be set with three preset access time segments at mos...

Page 24: ...segments which have an OR relation with one another The verification time is deemed valid only if it remains within one of these time segments The time bucket format is HH MM HH MM using a 24 hour clock If the end time is earlier than the start time 23 57 23 56 unlock is prohibited for a whole day If end time is later than the start time 00 00 23 59 unlock is valid within this time bucket Valid ti...

Page 25: ...unctions By using the grouping functions you can divide users into different groups and combine diverse groups to form different access combinations so as to facilitate access control management The system defines 5 groups Group 1 Group 2 Group 3 Group 4 and Group 5 Newly enrolled users belong to Group 1 by default but they can also be reassigned to other groups Group TS This parameter is used to ...

Page 26: ...l VerType Belong to GRP Divide the enrolled users into several groups to facilitate management Group TS Set whether the user adopts the default time segments of the group that he she belongs to User TS Set the user s unlocking time and select a set time segment number Group VerType Set whether the user adopts the verification types of the group that he she belongs to Individual VerType Select a ve...

Page 27: ...ype shall prevail even if user 00001 selects another individual verification type B Select User Acc Opts and set the UserID to 00002 User Acc Opts UserID 00002 ESC Exit OK Press OK to display the setting interface of user 00002 If the user time segments are numbered 1 and 20 the system will automatically set the option Use Grp TPs to N To set Group VerType to N set the option VERType individual ve...

Page 28: ...by default On the initial interface press Menu Options Access Options Access Comb as shown in the following figure Access Comb Comb 1 1 Comb 2 Comb 3 Comb 4 Comb 5 Comb 6 Comb 7 Comb 8 Comb 9 Comb 10 The default unlock combination is 1 and other unlock combinations are left blank To make all users unable to unlock leave all these ten unlock combinations BLANK To enable unlocking for some of the gr...

Page 29: ...s follows These three people respectively belong to Group 2 Group 4 and Group 5 and are granted the right to unlock within the same time segment Select Comb 1 and press OK Then enter 245 through the numeric pad and press ESC to exit and save the setting Tip Once the 245 combination is set combinations such as 24 25 and 45 are not allowed 4 5 3 5 Lock Driver Duration The lock driver duration refers...

Page 30: ...ress Options press Menu Options Access Options and then select Duress Options through the key as shown in the following figure Access Options DSen Delay 10 DSen Mode NO Duress Options The Duress Options include such options as the Duress FP Mng Help Key 1 1 Trig 1 n Trig Pwd Trig and Alarm Delay 4 5 4 1 Duress Fingerprint Management Users may specially enroll a new or specify an existing fingerpri...

Page 31: ...arm signal Duress Options Duress FP Help key 1 1 Trig N 1 N Trig N Pwd Trig N Alarm Delay 10 4 5 4 4 Alarm Delay Define automatic alarm time You can define an alarm delay to enable the system to automatically send a duress alarm signal after a period of time 0 255 seconds Under the menu Duress Options press to select Alarm Delay Duress Options 1 N Trig Y Pwd Trig Y Alarm Delay 10 4 5 5 Verificatio...

Page 32: ... and press OK Then press to select a verification type for this group and press OK to confirm your selection Finally press ESC to exit current interface and when the system prompts you to save your changes press OK Note The Group VerType option is available only for the devices supporting multiple verification modes ...

Page 33: ...nd check whether its LCD displays integral images Fingerprint Reader Test The FRT automatically tests whether the fingerprint reader works properly by checking After select it press OK to test and check it whether normal Press ESC to exit the test Keyboard Test The FRT tests whether every key on the keyboard works normally Press any key on the Keyboard Test interface to check whether the pressed k...

Page 34: ...ttlog dat attendance records X_oplog dat management records and X_user where X refers to the device ID are stored in the USB pen drive Tip If the download succeeds a prompt Copy Data Suc will pop up If the system displays the prompt Plug Pen Drive please check whether the USB pen drive is plugged in properly 5 2 Download Employee Data Employee data downloading is similar to the downloading of atte...

Page 35: ...o the USB interface on the FRT upon successful export and select Menu USB Mngt Upload SMS to upload the short message from the USB pen drive Notes 1 The option PenDrive Mng is available only on the FRTs configured with USB slots The options Upload SMS and Download SMS are available only on the SMS capable FRTs If you need FRTs that support these functions please consult our commercial representati...

Page 36: ...Att Log 8046 Admin Cnt 2 User Pwd 30 Alm Log 263 Free Cap Dev Info On the screen as shown in the figure above you can check the User Cnt Number of enrolled users FP Cnt Number of enrolled fingerprints Att Log Piece of attendance records Admin Cnt Number of enrolled administrators User Pwd Number of pass words and Alm Log Number of enrolled super administrators Through Free Cap you can check the fr...

Page 37: ...s User Manual 33 7 Turn Off Clear Alarm ê The option Turn Off Alarm is available only after the FRT generates an alarm and is used to clear an alarm Note The option Turn Off Alarm is available only after an alarm signal is generated ...

Page 38: ...lean the optical lens if they get blurry and the verification performance is affected Please refer to the following descriptions 2 Clean keyboards and LCD screens Before cleaning keyboards and LCD screens power off the FRT clean them with a piece of wet cloth or a neutral detergent and then wipe them with a piece of dry cloth 3 Clean optical lens Follow the suggestions below to clean the optical l...

Page 39: ...ot consistent with that of the FRT ƒ The FRT is not connected with the power supply or the PC The FRT is connected with the PC but not powered on The No of the connected terminal is incorrect The data cable or converter is faulty The COM port of the PC is faulty Question What are the possible causes of incomplete display sometimes half screen display or blurred screen after the FRT is powered on H...

Page 40: ... return the FRT for maintenance Question Why does a failure or error occurs when I read the attendance data while I can download fingerprint and password data properly How to fix it Answer This problem may relate to the data cable converter or the COM port setting of the PC You may try decreasing the baud rate of the PC and FRT for example set it to 19200 or 9600 before reading the attendance data...

Page 41: ...re upload the short message to the FRT and set it to be displayed on October 20th This message will be displayed on the screen once this employee verifies his her fingerprint A short message for a group of employees for example for a plenary meeting scheduled to be held on June 19th you can edit a short message Please attend the plenary meeting at in the meeting room you can edit it as required th...

Page 42: ...slave both controlling the same lock are connected by RS232 RS485 Wiegand 1 The Applications of the Master and the Slave 1 Record storage By default the master status is exit and the slave status is entry The records of entry and exit are both saved on the master 2 Anti Passback function Whether to perform the anti passback function is determined by the latest record of the user s entry and exit W...

Page 43: ... as wiegand26 without device ID 4 Enroll user The user must be on master machine and slave machine at the same time and user PIN must be the same Therefore it is necessary to enroll user on master machine and slave machine at the same time 5 Connection instruction Wiegand communication is adopted for master machine and slave machine Refer to the following for connection Master Slave IND0 WD0 IND1 ...

Page 44: ...d protocol for the 26 bit Wiegand card reader one pulse time ranges between 20us and 100us and the pulse jump time ranges between 200us and 20ms Data1 and Data0 are high level larger than Voh signals till the card reader prepares to send a data stream The asynchronous low level pulse smaller than Vol generated by the card reader is sent to the access control panel The saw tooth wave as shown in Fi...

Page 45: ...2 to 18 Facility code 0 to 131 071 Bit 2 is MSB Bits 19 to 38 ID Number 0 to 1 048 575 Bit 19 is MSB Bit 39 Odd parity over bits 20 to 38 Custom Wiegand Formats The second alternative is to create a custom Wiegand format Typically up to 64 bits are available for creating a custom Wiegand format With certain limitations formats with greater than 64 bits may be created If a customer currently has a ...

Page 46: ...ies and so on The EFUP of batteries is 5 years Names and Concentration of Toxic and Hazardous Substances or Elements Toxic and Hazardous Substances or Elements Parts Name Pb Hg Cd Cr6 PBB PBDE Chip resistor Ï Chip capacitor Ï Chip inductor Ï Chip diode Ï ESD components Ï Buzzer Ï Adapter Ï Screws Ï Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for t...