Specifications 

(continued)

Environmental and Operating Conditions

Parameter

Reference

Rated

Operative Limits

Transportation and storage

Ambient
Temperature

25 

±

 3

˚C

77 

±

 5

˚

F

15 to 55

˚

C

58 to 131

˚

F

0 to 55

˚

C

32 to 131

˚

F

-40 to 66

˚

C

-40 to 151

˚

F

Relative Humidity

10 to 55*

10 to 90*

5 to 90*

5 to 95*

Vibration
    Frequency (Hz)
    Acceleration (g)

0
0

0 to 70
0.1

0 to 200
0.5

0 to 200
0.5

Mechanical Shock
    Acceleration (g)
    Duration (ms))

0
0

1
30

5
30

20
30

Voltage (Vdc)

+24 

±

 1

20 to 27

20 to 27

- -

Voltage (Vac)

90 to 264Vac

(CSA models rated to 250V max.)

24Vac

120 

±

 1

240 

±

 2

24 

±

 1

90 to 264

20 to 27

90 to 264

20 to 27

- -
- -

- -

Frequency (Hz)

(For Vac)

50 

±

 0.2

60 

±

 0.2

49 to 51
59 to 61

48 to 52
58 to 62

- -
- -

*

 The maximum rating only applies up to 40˚C (104˚F). For higher temperatures, the RH specification is derated to maintain constant moisture  content.

Table 1 - Input Actuations

Range

PV Input

˚F

˚C

Thermocouples

B*
E*
E (low)
J
J (low)
K
K (low)
NiNiMoly (NNM)
NiNiMoly (NNM low))
NIC (Nicrosil Nisil)
R
S
T
T (low)
W5W26
W5W26 (low)

0

to 3300

-454

to 1832

-200

to 1100

0

to 1600

20

to 770

0

to 2400

-20

to 1000

32

to 2500

32

to 1260

0

to 2372

0

to 3100

0 to 3100

-300

to 700

-200

to 500

0

to 4200

0 to 2240

-18

to

1815

-270

to

1000

-129

to

593

-18

to

871

-7

to

410

-18

to

1316

-29

to

538

0

to

1371

0

to

682

-18

to

1300

-18

to

1704

-18

to

1704

-184

to

371

-129

to

260

-18

to

2316

-18

to

1227

RTD
(IEC) ALPHA = 0.00385
100 Ohms
100 Ohms (low)
500 Ohms

-300

to 1200

0

to 300

-300

to 1200

-184

to

649

-18

to

149

-184

to

649

Radiamatic RH

1400

to 3400

760

to 1871

Linear**

Milliamps
Millivolts

Volts

4

to 20 mA

0

to 10 mV

10

to 50 mV

1

to 5V

0

to 10V

Optional 2nd Input

Milliamps
Volts
Slidewire for Position
Proportioning

4

to 20 mA

1

to 5V

100

to 1000

* May require Field calibration to achieve rated accuracy below 1000 

˚

F for type B and below -200 

˚

F for type E thermocouple.

** Not available on FM approved Limit models.

Summary of Contents for Versa-Pro UDC3000

Page 1: ...nfigurable upscale or downscale burnout and failsafe output level Decimal Point Location Configurable for none one or two places Accutune IITM Provides a new truly plug and play tuning algorithm which will at the touch of a button or through a digital input accurately identify and tune any process including those with deadtime and integrating processes This speeds up and simplifies startup plus al...

Page 2: ... only 2 Digital Inputs Allows remote dry contact closure to select one of the following for each digital input Manual control mode Local setpoint 1 Local setpoint 2 Direct controller action Reset of Limit Controller Hold SP Ramp Programming Select PID set 2 PV Input 2 External program reset Disable PID integral action To Run SP Ramp Program To Automatic output value Manual mode failsafe output Dis...

Page 3: ...d for these output algorithms Control Algorithms Depending on the output algorithms specified the controller can be configured for the following control algorithms On Off PID A PID B PD with Manual Reset Three Position Step Control The Three Position Step Control algorithm allows the control of a valve or other actu ator with an electric motor driven by two controller output relays one to move the...

Page 4: ...ion of when Remote Setpoint is active the status of the control relays and whether a setpoint program is in Run or Hold mode A 21 segment bargraph displays deviation to 10 of span and an On Control indicator Displays A 4 digit upper display is dedicated to the process vari able during normal operation with alternate 6 character information displayed when in the configure mode During normal operati...

Page 5: ...ation of Conformity 51309303 000 Accuracy 0 20 of span typical 1 digit for display 15 bit resolution typical Temperature Stability 0 01 of Full Scale C change Input Signal Failure Protection Thermocouple Inputs Upscale or downscale burnout Burnout Current 0 13 microamps Failsafe Output Level Configurable 0 100 Input Impedance 4 20 Milliampere Input 250 Ohms 0 10 Volt Input 200K Ohms All Other 10 M...

Page 6: ...amps 55 C and 120 or 240 Vac Inductive Load 50 VA 120 Vac or 240 Vac Motor Rating 1 HP 25 C 0 75 HP 55 C Controller Output Algorithms On Off or Time Proportional One relay or open collector output Control action can be set for direct or reverse Time Proportional Relay Resolution 3 3 msec On Off Duplex Three Position Step Control or Time Proportional Duplex Two relays or open collector outputs Cont...

Page 7: ...will respond according to how each digital input is configured Opening contact causes return to previous state Input Filter Software Single pole lowpass section with selectable time constants off to 120 seconds available on both analog inputs Digital Displays Vacuum fluorescent alphanumeric A six character upper display dedicated to the process variable 4 digits Alternate information displayed dur...

Page 8: ...tent Table 1 Input Actuations Range PV Input F C Thermocouples B E E low J J low K K low NiNiMoly NNM NiNiMoly NNM low NIC Nicrosil Nisil R S T T low W5W26 W5W26 low 0 to 3300 454 to 1832 200 to 1100 0 to 1600 20 to 770 0 to 2400 20 to 1000 32 to 2500 32 to 1260 0 to 2372 0 to 3100 0 to 3100 300 to 700 200 to 500 0 to 4200 0 to 2240 18 to 1815 270 to 1000 129 to 593 18 to 871 7 to 410 18 to 1316 2...

Page 9: ...troller Model Number Interpretation Output 1 C Current 4 20mA without Alarms K Current 4 20mA with Alarm 1 E Relay Electromechanical 5AMP with Alarm 1 A Relay Solid State AC 1AMP with Alarm 1 T Open Collector Output 20mA with 1 Alarm D C 3 0 0 Output 2 or Alarm 2 O None E Relay Electromechanical 5AMP SPDT A Relay Solid State AC 1AMP SPST T Open Collector Output 20mA External Interface O None 1 RS4...

Page 10: ...RSP OUT 1 2 1 2 F C MAN DI FUNCTION LOWER DISPLAY MANUAL AUTO SETPOINT SELECT SET UP HOLD 1 2 24 945 Max Panel Thickness 10 394 Max 2 5 82 147 3 21 6 850 093 2 4 with optional rear cover 90 7 3 57 22073 0 008 92 3 622 0 03 0 0 0 0 0 008 92 3 622 0 03 0 0 0 0 RUN 96 3 780 Figure 5 UDC3000 Versa Pro Controller dimensions not to scale ...

Page 11: ... 11 12 13 14 15 16 17 DI 1 TX or AUX TX or AUX RX TX RX TX SHIELD DI 2 UDC 3000 EXTERNAL WIRING L1 H L2 N 22 23 24 25 26 27 IN 1 IN 2 0 Instrument Power 22840 NOTE The product manual should be consulted for specific details and precautions regarding wiring Figure 6 External Wiring Diagram ...

Page 12: ...l Automation and Control 16404 North Black Canyon HWY Phoenix AZ 85023 800 343 0228 In Europe Honeywell S A 80084 Amiens Cedex 2 33 22 54 56 56 Honeywell Control System Ltd Honeywell House Bracknell UK RG 12 1 EB 44 1344 826000 In Japan Yamatake Honeywell Co Ltd Nagai Int l Bldg 2 12 19 Shibuya Ku Tokyo 150 Japan 81 3 3486 2051 In Asia Honeywell Asia Pacific Inc Room 3213 3225 Sun Hung kai Centre ...

Reviews: