TL6120

      69-1903EF                    1/16/06                    1/2

The TL6120 thermostat can be used to control an electric heating
system such as a baseboard heater, a radiant floor, a radiant ceiling,
a convector, a fan-forced heater, etc.

The thermostat cannot be used with the following:

a resistive load under 2 A

a resistive load over 12.5 A

systems driven by a contactor or a relay (inductive load)

central heating systems

One (1) thermostat

Two (2) 6-32 mounting screws

Two (2) solderless connectors

TURN OFF POWER TO THE HEATING SYSTEM AT THE MAIN
POWER PANEL TO AVOID ELECTRICAL SHOCK.

Loosen the screw under-
neath the thermostat and
separate the front plate
from the back plate.

NOTE: The screw cannot
be completely removed.

Connect the thermostat wires to the power and to the load using
solderless connectors for copper wires. The thermostat wires are not
polarized; meaning either wire can be connected to the load or to the
power supply.

NOTE: All cables and connections must comply with local electrical
codes. This thermostat has tinned copper wires for line and load con-
nections. Special CO/ALR solderless connectors must be used if
these wires will be connected to aluminium conductors.

Mount the back plate to the electrical
box using the provided screws. Insert
the screws through a pair (left or right)
of mounting holes on the back plate.

Re-install the front plate of
the thermostat onto the
back plate and secure it
with the screw underneath
the thermostat.

NOTE

: If there is a protective film or sticker on the thermostat’s

screen, peel it off.

Apply power to the heating system. Verify the installation by checking
that the heater can be turned On and Off by raising and lowering the

setpoint using the 

 buttons.

ATTENTION

: Keep the thermostat's air vents clean and free from

obstructions at all times.

n

Description

1.

o

Supplied Parts

2.

p

Installation

3.

TL6120

Installation Guide

5-2 Programmable Thermostat

4-wire Installation

2-wire Installation

Summary of Contents for TL6120

Page 1: ...onnected to the load or to the power supply NOTE All cables and connections must comply with local electrical codes This thermostat has tinned copper wires for line and load con nections Special CO ALR solderless connectors must be used if these wires will be connected to aluminium conductors Mount the back plate to the electrical box using the provided screws Insert the screws through a pair left...

Page 2: ...kering especially in rural regions The FAN indicator is displayed when conventional control is selected To switch between the two types of control n Pull the cover down o Press and hold the button p Insert a pointed object e g paperclip through the reset open ing Remove it when the thermostat s screen becomes blank q Wait one second and release the button Warning When the thermostat is reset all p...

Page 3: ...ostat ne sont pas polarisés Donc le sens du branchement n a aucune importance NOTA Tous les câbles et les raccordements doivent être conformes au code d électricité local Les fils du thermostat qui servent aux rac cordements de ligne et de charge sont étamés Des connecteurs CO ALR spéciaux doivent être utilisés si ces fils doivent être reliés à des conducteurs d aluminium Fixer la base sur une boî...

Page 4: ...de l éclairage surtout en région rurale La mention FAN s affiche lorsque la régulation classique est utilisée Pour changer le type de régulation n Tirer le couvercle vers le bas o Appuyer sur le bouton et le maintenir enfoncé p Insérer un objet pointu comme un trombone dans l ouverture de réinitialisation Enlever le trombone lorsque l affichage dispa raît de l écran q Attendre une seconde et relâc...

Reviews: